Untitled
Abstract: No abstract text available
Text: Instruction Sheet 408-4050 03 MAR 11 Rev E AMP-O-LECTRIC* Model “G” Terminating Machine Ref NOTE: Refer to Drawing 1320431 for CQM Adapter Hookup to the AMP 3K/ AMP 5K Terminating Machines Crimp Quality Monitor (Ref) Ram Assembly CQM Adapter Figure 1
|
Original
|
PDF
|
|
sheet metal press bending machine
Abstract: motor operated valve panel crimp quality monitor STOP WIRE SIDE FEED APPLICATOR maintenance manual terminating machine minimum wipe length engagement
Text: AMP-O-LECTRIC* Model G" Terminating Machines 354500-[ ] and 1213127-[ ] Customer Manual 409-5842 29 MAY 07 Rev H SAFETY PRECAUTIONS 1. INTRODUCTION READ THIS FIRST ! . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
|
Original
|
PDF
|
|
408-8547
Abstract: AMP crimper 854040-3 amp 408-8547 Crimping micro applicator AMPOMATOR CLS IV bellmouth adjustment for applicators Instruction Sheet 408-8547 234604-1 amp 408-9938 AMP mate-n-lok terminal crimp height
Text: Soft Shell Pin and Socket Connectors AMP Application Tooling Semiautomatic Machines AMP-O-LECTRIC Model “G” Terminating Machines, 354500-1, -9, -11 AMP 3K/40 and AMP 5K/40 Terminators Specifications Width—18.7-25.3 [475-643] depending on applicator type
|
Original
|
PDF
|
3K/40
5K/40
Width--18
Depth--21
Height--20
Weight--240
408-8547
AMP crimper 854040-3
amp 408-8547
Crimping micro applicator
AMPOMATOR CLS IV
bellmouth adjustment for applicators
Instruction Sheet 408-8547
234604-1
amp 408-9938
AMP mate-n-lok terminal crimp height
|
crimp quality monitor
Abstract: 567200-2 sheet metal press bending machine STOP WIRE SIDE FEED APPLICATOR MINIATURE CIRCUIT BREAKER maintenance instruction k 1358 Lift Controller Circuit mate-n-lok crimp height good crimping bad crimping 8128 RAM
Text: AMP-O-LECTRIC* Model “G” Terminating Machines 354500-[ ] Customer Manual 409-5842 SAFETY A. PRECAUTIONS READ THIS FIRST ! ORIGINAL INSTRUCTIONS customer manual 03 DEC 10 Rev L . 2 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
|
Original
|
PDF
|
|
354500-1
Abstract: crimp counter
Text: AMP-O-LECTRIC Model G Terminating Machine Fast Facts • Quieter • Improved guarding and lighting • Toolless changeover of applicators • Precision manual- or autoadjust for crimp height • Total and batch counter • Accepts all existing TE miniature
|
Original
|
PDF
|
|
crimp quality monitor
Abstract: 354500-1 354500-9 1490503-1 applicators 3545001
Text: AMP-O-LECTRIC Model G Terminating Machine Fast Facts • Quieter • Improved guarding and lighting • Toolless changeover of applicators • Precision manual- or autoadjust for crimp height • Total and batch counter • Accepts all existing Tyco Electronics miniature
|
Original
|
PDF
|
|
CHAMPOMATOR 2.5 BENCH TERMINATING MACHINE
Abstract: amp quality crimping handbook MT 6327 crimp quality monitor tyco 108-25034 plastic 1307819 AMP 91085-2 9318001 Tyco crimp tool 91517-1 58-0202
Text: AMPMODU Interconnection System Application Tooling for Wire Crimp Contacts Tooling shown on this page is designed to terminate wire crimp contacts used in various AMPMODU wire-toboard connectors. Refer to page 87 to determine the applicable connectors. AMP-O-LECTRIC Model “G” Terminating Machine
|
Original
|
PDF
|
64-Position
CHAMPOMATOR 2.5 BENCH TERMINATING MACHINE
amp quality crimping handbook
MT 6327
crimp quality monitor
tyco 108-25034 plastic
1307819
AMP 91085-2
9318001
Tyco crimp tool 91517-1
58-0202
|
Untitled
Abstract: No abstract text available
Text: AMPMODU Interconnection System Application Tooling for Wire Crimp Contacts Tooling shown on this page is designed to terminate wire crimp contacts used in various AMPMODU wire-toboard connectors. Refer to page 88 to determine the applicable connectors. AMP-O-LECTRIC Model “G” Terminating Machine
|
Original
|
PDF
|
|
customer manual 409-5128
Abstract: tyco applicator data Applicator STOP WIRE SIDE FEED APPLICATOR hand drill 690671 AN 7468 amp-o-lectric terminating machine
Text: AMP-O-LECTRIC* Terminating Machine Conversion Kits 690675-2 and 692613-1 for Miniature Quick-Change Applicators ITEM NO. PART NO. Instruction Sheet 408-8022 06 FEB 09 DESCRIPTION Rev A QTY 1 690671–1 PLATE, Base 1 2 690672–2 MOUNT, Base 1 3 4–21002–4
|
Original
|
PDF
|
|
Tyco 114-2078
Abstract: faston flag receptacles crimp height tyco crimp height specification faston flag receptacles with tab-lok crimp AMPOMATOR CLS IV 47417 TE 250 for crimping 114-2078 LR7189 bellmouth standard
Text: Application Specification 114-2078 FASTON* Flag Receptacles with Tab-Lok Feature NOTE i 06 AUG 08 Rev M All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
checking terminal crimp height SPLICE TERMINAL
Abstract: general maintenance for applicators crimp dimension tolerance tyco crimp height specification BLANKET INSULATION
Text: Application Specification AMPLIVAR* 114-2003 9-Serration Pigtail Splice NOTE NOTE 13 JAN 05 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
AMPOMATOR CLS IV
Abstract: amp 114-1016 408-8040 408-9640 MINIAPPLICATOR bellmouth standard
Text: Application Specification 114-1016 Miniature AMP-IN* Contacts NOTE i 01 JUL 08 Rev W All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
general maintenance for applicators
Abstract: checking terminal crimp height SPLICE TERMINAL 408-7424 bellmouth tyco crimp height specification AMPOMATOR CLS IV
Text: Application Specification 114-2088 Open Barrel Pigtail and Thru Splices NOTE NOTE 29 NOV 04 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
amp o lectric model k
Abstract: LR7189 408-7424 F crimp extraction tool tyco 408-7497
Text: Application Specification Blade Contacts 3.18 X 0.51 mm [.125 X .020 in.] Mating Receptacles and Housings NOTE i 114- 2145 09 FEB 10 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
|
Original
|
PDF
|
|
|
splice conductors
Abstract: No abstract text available
Text: Application Specification 114-2147 Nylon Closed End Splices NOTE i 09 SEP 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
Tyco crimp tool 91510-1
Abstract: 408-8547 408-9476 8547 stock 91508 305183 91510-1 350561 350654 91500-1
Text: Instruction Sheet 408-7300 MATE-N-LOK* Contact and Housing Selection Charts 04 DEC 08 Socket Contact Insulation Rev B Pin Contact Locator Slot Locator Slot Barrel Wire Strip Length Wire Strip Wire Barrel Length Wire Barrel Insulation Barrel NOTE: Strip length is 4.75 mm [.197 in.] for wire size range 30-14; and 6.35 mm [.250 in.] for 12-10 wire size range.
|
Original
|
PDF
|
|
bellmouth standard
Abstract: 408-9640 bellmouth faston crimp height crimp quality monitor faston 250 crimp height
Text: Application Specification 114-2070 AMPLIVAR* FASTON* Tab Contacts NOTE i 08 DEC 08 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
AMPOMATOR CLS IV
Abstract: tyco crimp height chart III-G AMPOMATOR tyco crimp height chart for 24 awg wire maintenance manual 565435-5 354500-1
Text: Application Specification 114-2019 Cluster Block Housings and Contacts 05 NOV 08 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
general maintenance for applicators
Abstract: tyco crimp height specification 408-8040 SDE PEW 12 assembly AMPOMATOR CLS IV SDE PEW 12
Text: Application Specification 114-13133 Next Generation NG 1.5 mm Contact System NOTE NOTE 23 JUN 05 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless otherwise specified, dimensions have a tolerance of +0.13 and angles have a tolerance of +2 . Figures and
|
Original
|
PDF
|
|
AMP Faston flag connector
Abstract: faston flag receptacles with tab-lok crimp 114-2079 LR49710 114-2078 2082 tyco 408-7424 FASTON connector faston flag receptacles crimp height 1725950-3
Text: Application Specification 114-2032 FASTON* Reversible Flag Receptacles 30 JUL 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
faston flag receptacles crimp height
Abstract: F crimp 2082 tyco .110 faston tab 408-8039 4-0992 crimp dimension tolerance
Text: Application Specification FASTON* 110 Series Flag Receptacles with F" Crimp Feature NOTE i 114-2028 02 APR 08 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 mm [+.005 in.] and angles have a tolerance
|
Original
|
PDF
|
|
114-13089
Abstract: amp hdi applicator 567067-1 567067-3 114-13105 455830-1 408-9640 E2003 H314 408-7347
Text: Application Specification 114–13105 Miniature Circular Plastic Connector CPC NOTE 16 SEP 03 Rev O All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Catalog 1307612 AMP Power Lock Connectors Revised 7-01 Application Tooling Series I Connector Tooling The Series I AMP Power Lock Contact can be terminated in the industry accepted AMP-O-LECTRIC Semiautomatic Terminating Machine. This machine accepts a special side-feed
|
OCR Scan
|
PDF
|
|
bellmouth adjustment for applicators
Abstract: crimp quality monitor 408-9476 Instruction Sheet 408-2095 90869-1 90247-1 PG57M 90123-2 90124-2 90546-1
Text: Soft Shell Pin and Socket Connectors C a ta lo g 8 2 1 8 1 Revised 7-97 Application Tooling Machines Automatic and Semi-Automatic AMP-O-LECTRIC Model “ G” Terminating Machines, 354500-1 , - 9 , - 1 1 AMPOMATOR CLS IV+ Lead-Making Machines, 356500-1 , - 2
|
OCR Scan
|
PDF
|
n869-1
bellmouth adjustment for applicators
crimp quality monitor
408-9476
Instruction Sheet 408-2095
90869-1
90247-1
PG57M
90123-2
90124-2
90546-1
|