WC109
Abstract: elliptical waveguide l46r WC166 wc 128 circular LDF7P-50A-1A 48940-C LDF4P-50A-1 L44R L5PNM
Text: Microwave and Wireless System Planning System Planning Worksheet. Ask for Andrew Bulletin 8740. System Using C ircular and E llip tica l Waveguide Towers Because we manufacture all the system components, Andrew has a unique understanding of how to design a tower to properly support transmission lines and hold
|
OCR Scan
|
PDF
|
H12PNF
H12PDM
2396A-2
2396A-4
2396A-5
19256B
4312A
WC109
elliptical waveguide
l46r
WC166
wc 128 circular
LDF7P-50A-1A
48940-C
LDF4P-50A-1
L44R
L5PNM
|
WC166
Abstract: p-5 RELAY WC281 WC109 EWP52 coaxial cable group chart microwave waveguide EW240 EW20 elliptical waveguide
Text: Transmission Lines Widest Selection of microwave transmission lines in the industry. Andrew offers sizes and types that are optimized for nearly every application. HELIAX Coaxial Cables and Elliptical Waveguides have been, for many years, the standard transmission
|
OCR Scan
|
PDF
|
sR137,
WR112
WC281,
WC166
WC166
p-5 RELAY
WC281
WC109
EWP52
coaxial cable group chart
microwave waveguide
EW240
EW20
elliptical waveguide
|
andrew 4 port
Abstract: WC281 4 port combiner Andrew ANTENNA 6,4 waveguide elliptical connector
Text: ANDREW. SPECIFICATIONS FOR 4-PORT C O M B IN IN G NETWORK FOR SHX SUPER HIGH PERFORMANCE ANTENNA TYPE 205136 5 .9 2 5 -6 .4 2 5 GHz and and 1 0 .7 0 - 11.70 GHz Andrew's new compact 4 - port combining network is designed for use in SHX super high performance antenna systems and other circular waveguide applications. It
|
OCR Scan
|
PDF
|
153rd
SP20-41
WC281
WC166
CQ462
252DET
190DET
EWP52
EWP90
andrew 4 port
4 port combiner
Andrew ANTENNA 6,4
waveguide elliptical connector
|
190DET
Abstract: EWP90S EWP90-107 F090PC0240CB andrew ew90 EWP90 andrew ewp90 190DEMT CPR-90G 190DE
Text: Characteristics Type Numbers Super Premium Waveguide, Standard Jacket Premium Waveguide, Standard Jacket Standard Waveguide, Standard Jacket Premium Waveguide, Fire Retardant, Non-Halogenated Jacket Premium Waveguide Type CATVP EWP90S EWP90 EW90 35409-16*
|
OCR Scan
|
PDF
|
ns/100
190DZ
5849A-15
1108A-1
1108A-2
1108A-3
190DET
EWP90S
EWP90-107
F090PC0240CB
andrew ew90
EWP90
andrew ewp90
190DEMT
CPR-90G
190DE
|
EWP90-105
Abstract: WGB4-90 190DEMT 190SE 55000A F090PC0240CA 223306-100 EWP90 EWP90-107 andrew ewp90
Text: Ordering Information for Waveguide Assem blies Frequency* GHz Waveguide Type Connector* Tunable Fixed-Tuned Flange Typett Super Premium Waveguide Assemblies 10.7-11.7 EWP90S VSW R 1.05 32.3 * CPR90G PDR100 190DET 190DEMT 190SE 190SEM 55001-90 223306-100
|
OCR Scan
|
PDF
|
CPR90G
PDR100
190DET
190DEMT
190SE
190SEM
F090PC0240CB
F090MH0600HB
EWP90-105
WGB4-90
55000A
F090PC0240CA
223306-100
EWP90
EWP90-107
andrew ewp90
|
Andrew Rxl5-1RNT
Abstract: Andrew RADIAx Andrew Rxl4 RXL5 - 1RNT RXL4 - 1RNT RXL4 RXL4-2RNT Andrew RXL2-2RNT RXL6 LDF4RN-50A
Text: HELIAX Coaxial Cables Fire Retardant Cables and Waveguides Fire R etardance Requirem ents Cable and waveguide installed inside a building usually must meet fire retardance requirements. In the United States, the National Electrical Code NEC ’ sets the standard for coaxial cable used within buildings and
|
OCR Scan
|
PDF
|
|
1132DCT
Abstract: Pressure window antenna 14.4-15.35 1220ASC
Text: Microwave and Wireless System Planning are included. A planar radome, where applicable, is included; an optional molded radome is not included. The components listed in the tables are examples, not complete product listings. See the referenced pages for complete descriptions, specifications, ordering informa
|
OCR Scan
|
PDF
|
|
EW34
Abstract: EW180 EWP34
Text: Grounding Kits A well designed system uses grounding kits to provide a bond between the elliptical waveguide and the tower/earth ground system. One grounding kit is recommended at tower top, tower bottom, at 200 ft 60 m intervals (where applicable), and at the entrance to the equipment shelter.
|
OCR Scan
|
PDF
|
MIL-STD-188-124A.
elim36
EWP17
EWP34
EWP37,
EWP37S
EWP43
EWP52,
EWP52S
EWP63,
EW34
EW180
|
EW63 waveguide
Abstract: EWP37 EWFTK-52 EWP63 ew52 waveguide elliptical EW77 P127A
Text: Grounding Kits Easy Installation A well designed system uses grounding kits to provide a bond between the elliptical waveguide and the tower/earth ground system. One grounding kit is recom mended at tower top, tower bottom, at 200 ft 60 m intervals (where applicable), and at the entrance to the
|
OCR Scan
|
PDF
|
EWP37,
EWP43
EWP52,
EWP63,
EWP90,
EW127A,
P127A
EW180,
EW220,
EWFTK-43
EW63 waveguide
EWP37
EWFTK-52
EWP63
ew52
waveguide elliptical
EW77
|
RXL7 connector
Abstract: RXL4 - 1RNT RXL6 Andrew Rxl6 CONNECTOR RxL4-1rn RXL4-2RNT LDF5RN-50A VXL5RN-50 Andrew RADIAX RXL-4 EFX2RN-50
Text: Fire Retardant Cables and Waveguides Fire Retardance Requirements Cable and waveguide installed inside a building usually must meet fire retardance requirements. In the United States, the National Electrical Code NEC 1 sets the stan dard for coaxial cable used within buildings and normally
|
OCR Scan
|
PDF
|
|
CPR-90G
Abstract: EW90 andrew waveguide
Text: Elliptical W aveguide Types EWP90S, EWP90 and EW90 Characteristics T yp e N u m be rs Super Premium Waveguide, Standard Jacket Premium Waveguide, Standard Jacket Standard Waveguide, Standard Jacket Premium Waveguide, Fire Retardant, Non-Halogenated Jacket
|
OCR Scan
|
PDF
|
EWP90S,
EWP90
ns/100
CPR-90G
EW90 andrew waveguide
|
EWP90-105
Abstract: No abstract text available
Text: Ordering Information fo r HELIAX Elliptical Waveguide Assemblies Frequency' GHz Flange T y p e tt Waveguide Type Tunable C o nn ectort Pre-Tuned Fixed-Tuned Super Premium Waveguide Assemblies 10.7-11.7 EWP90S Flex-Twist 2 ft 0.6 m Pressure W indow VSWR 1.05 (32.3)*
|
OCR Scan
|
PDF
|
EWP90S
CPR90G
PDR100
190DET
190DEMT
F090PC0240CB
F090MH0600HB
EWP90-105
|
EW90 andrew waveguide
Abstract: ew52 EW52 waveguide EW132 waveguide elliptical EWFTK-52 EW63 waveguide EWFTK-63
Text: Grounding Kits / Flaring Tools Kits Include Standard Grounding Kits for Ellip tical W aveguide. Series 204989 and 241088 kits include a solid copper strap riveted to the grounding wire, a coil tool for proper tightening, tower attachment hardware, and a two-part
|
OCR Scan
|
PDF
|
EWP37,
EWP37S
EWP52,
EWP63,
EWP64
EWP77
EWP90,
EW127A,
P127A
EW132,
EW90 andrew waveguide
ew52
EW52 waveguide
EW132
waveguide elliptical
EWFTK-52
EW63 waveguide
EWFTK-63
|
EWP43
Abstract: EWP63 EW17 EW132 EW34
Text: M ic ro w a v e T ra n s m is s io n Lines H anger Spacing fo r h e l ia x Elliptical waveguide Recommended maximum hanger spacings are tabulated below for various wind speed and ice conditions. The recommendations are based on guidelines stated in EIA
|
OCR Scan
|
PDF
|
RS-222
EWP34
EWP37
EWP43
EWP52
EWP63
EWP64
EWP77
EWP90
EWP127A
EW17
EW132
EW34
|
|
EWP77
Abstract: EW77 ew52 stainless steel bolt and galvanized andrew ew90
Text: Elliptical W aveguide Hangers A , B W a ve g u id e H a n g e r K it of 10 stainless steel hangers. Mount with 3/8" hardware or adapters. R ec om m en d ed M a xim u m F o r W avegu ide W ave gu ide Photo Type Nu m be rs H a n g e r Kit R e f. ft m 3 17 6 6 A -9
|
OCR Scan
|
PDF
|
Hanger/45°
EWP77
EW77
ew52
stainless steel bolt and galvanized
andrew ew90
|
EWP90S
Abstract: No abstract text available
Text: M icrow ave Tran sm issio n Lines 42396A Series Gripping Tabs Prevent waveguide slippage without the need for a hoisting grip. Pre-Assem bled and C aptivated Hardw are Eliminates the need for field assembly. Springlike Flexibility Makes it easy to form the hanger around the waveguide
|
OCR Scan
|
PDF
|
2396A
EWP17
EWP34
EWP37,
EWP37S
EWP43
EWP52,
EWP52S
EWP90S
|