Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ATEX 1518 Search Results

    ATEX 1518 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    ISO7021D Texas Instruments Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 Visit Texas Instruments
    ISO7021FD Texas Instruments Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 Visit Texas Instruments
    LPD3015-182MLB Coilcraft Inc General Purpose Inductor, 1.8uH, 20%, 2 Element, Ferrite-Core, SMD, ROHS COMPLIANT Visit Coilcraft Inc
    LPS3015-182MLC Coilcraft Inc General Purpose Inductor, 1.8uH, 20%, 1 Element, Ferrite-Core, SMD, 1212, ROHS COMPLIANT Visit Coilcraft Inc
    LPS5015-182MLC Coilcraft Inc General Purpose Inductor, 1.8uH, 20%, 1 Element, Ferrite-Core, SMD, 1919, ROHS COMPLIANT Visit Coilcraft Inc

    ATEX 1518 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-N1/2A4-NAEX/D100 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-N1/2A4-NAEX/D100 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2A4-NAEX/D100 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-GL1/2A4-NAEX/D100 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NAEX/L065/D100 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-G1/2A4-NAEX/L065/D100 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2T-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-GL1/2T-NAEX-H1141 70cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2HC22-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-GL1/2HC22-NAEX-H1141 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2A4-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-GL1/2A4-NAEX-H1141 100cm/s 25ong 2013-07-13T18 D-45472 PDF

    en5001

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2A4-NAEX • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor ■


    Original
    100cm/s 2013-07-13T18 D-45472 en5001 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G3/4A4-NAEX/D100 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-G3/4A4-NAEX/D100 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-N1/2A4-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-N1/2A4-NAEX-H1141 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/4A4-NAEX/D100 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-G1/4A4-NAEX/D100 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-G1/2A4-NAEX-H1141 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2TN-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-GL1/2TN-NAEX-H1141 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/4A4-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-G1/4A4-NAEX-H1141 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G3/4A4-NAEX-H1141 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-G3/4A4-NAEX-H1141 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NAEX/D100 • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor


    Original
    FCS-G1/2A4-NAEX/D100 100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2T-NAEX • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor ■ Sensor made of PTFE


    Original
    70cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2A4-NAEX/A • ATEX category II 2 G, Ex Zone 1 ■ Ex sensor for gaseous media ■ Calorimetric principle ■ ■ Adjustment via potentiometer at Ex signal processor Status indicated via LED chain on signal processor


    Original
    2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2A4-NAEX-H1141/A • ATEX category II 2 G, Ex Zone 1 ■ Ex sensor for gaseous media ■ Calorimetric principle ■ ■ ■ Adjustment via potentiometer at Ex signal processor Status indicated via LED chain on signal processor


    Original
    FCS-GL1/2A4-NAEX-H1141/A 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G3/4A4-NAEX • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor ■ EEx ib IIC T6 use in zone 1


    Original
    100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/2TN-NAEX • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor ■ Sensor made of Titanium B3 with metal-ceramic coating


    Original
    100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-GL1/2A4-NAEX/A/D100 • ATEX category II 2 G, Ex Zone 1 ■ Ex sensor for gaseous media ■ Calorimetric principle ■ ■ Adjustment via potentiometer at Ex signal processor Status indicated via LED chain on signal processor


    Original
    FCS-GL1/2A4-NAEX/A/D100 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-N1/2A4-NAEX • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor ■ EEx ib IIC T6 use in zone 1


    Original
    100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/4A4-NAEX • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor ■ EEx ib IIC T6 use in zone 1


    Original
    100cm/s 2013-07-13T18 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NAEX • ATEX category II 2 G, Ex Zone 1 ■ Ex flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via signal processor ■ Status displayed via signal processor ■ EEx ib IIC T6 use in zone 1


    Original
    100cm/s 2013-07-13T18 D-45472 PDF