Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CONDUIT HOOKS Search Results

    CONDUIT HOOKS Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Tinley Park, Illinois 60487 For more information Visit us at www.panduit.com Contact Customer Service by email: [email protected] or by phone: 800-777-3300 1P WACB24-SA-ENG 2013 Panduit Corp. ALL RIGHTS RESERVED Printed in the U.S.A. Catalog Number WACB24-SA-ENG


    Original
    WACB24--SA-ENG NFF146TI TTS-20R0 TTS-35R3-0 TTS-35RX0 PDF

    CHS2437

    Abstract: conduit hooks UNHC2816 threaded rod rod 420 UNHC2832 UNHC2864 CONDUIT cushion conduit clamp
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0903-2 Name: 8L-903 100: DATE: JAN 19 2006 Time: 6:00:11 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 No Wireway Opening UNHC Flexible Luminaire Hangers 8L For Support Only


    Original
    SYS19: CRMAIN06-0903-2 8L-903 CHS1437 CHS2437 UNH13 CHS3437 66008com CHS2437 conduit hooks UNHC2816 threaded rod rod 420 UNHC2832 UNHC2864 CONDUIT cushion conduit clamp PDF

    conduit hooks

    Abstract: incandescent luminaire pendant CHS2437 UNH182 UNHC216 UNHC232 UNHC264 UNHC2816 UNHC2832 threaded rod
    Text: Cl. I, Div. 2, Groups A, B, C, D UNE, UNH and UNHC Flexible Luminaire Hangers 8L For Pendant Mount The following applies to all items on this page: Applications: • Provides a simple, inexpensive, quick disconnect method for hanging pendant luminaires; for incandescent, H.I.D., and


    Original
    CHS1437 CHS2437 CHS3437 UNH13 conduit hooks incandescent luminaire pendant CHS2437 UNH182 UNHC216 UNHC232 UNHC264 UNHC2816 UNHC2832 threaded rod PDF

    SEC100G

    Abstract: No abstract text available
    Text: Kellems Wire Management Products www.hubbell-wiring.com Pulling Grips Support Grips Strain Relief Grips Cord Connectors Index Index Product Page Kellems® Wire Mesh Grips Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-2


    Original
    T-116 SEC100G PDF

    lock solenoid

    Abstract: D4BL-2CRA EN1088 EN60947-5-1
    Text: Guard Lock Safety-door Switch D4BL Protective Doors Are Locked Until Machines Completely Stop Operating • A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety is achieved using a mechanism where the lock is only


    Original
    D-147 lock solenoid D4BL-2CRA EN1088 EN60947-5-1 PDF

    BURN GI CONDUIT

    Abstract: zb omron D-104 D4BS-15FS D4BS-25FS D4BS-45FS EN60947-5-1 GI CONDUIT
    Text: Safety-door Switch D4BS Safety-door Switch’s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site • Conforms to EN TÜV standards corresponding to the CE marking. • Approved by UL, CSA, BIA, and SUVA standards.


    Original
    EN60947-5-1) D-112 BURN GI CONDUIT zb omron D-104 D4BS-15FS D4BS-25FS D4BS-45FS EN60947-5-1 GI CONDUIT PDF

    EN1088

    Abstract: EN60947-5-1 G-192
    Text: F502-EN2-04.book Seite 185 Dienstag, 26. Juli 2005 5:48 17 Guard Lock Safety-door Switch D4BL Protective Doors Are Locked Until Machines Completely Stop Operating • A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety is


    Original
    F502-EN2-04 C100-E2-03A-X G-196 EN1088 EN60947-5-1 G-192 PDF

    Lapp USA ST13.5

    Abstract: D4DS-55FS D4DS-25FS OA-W1609 D4DS-1AFS D4DS-15FS d4dsk3 D4DS-6AFS 53015030 zb omron
    Text: D4DS Safety-Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors H Conforms to EN TÜV standards. (positive H H H H H opening mechanism is indicated on the switch) Wide standard operating temperature range: -30 to 70°C Double-insulation structure (with


    Original
    EN50047 EN1088 EN60947-5-1 R9551708 UL508 E76675 Lapp USA ST13.5 D4DS-55FS D4DS-25FS OA-W1609 D4DS-1AFS D4DS-15FS d4dsk3 D4DS-6AFS 53015030 zb omron PDF

    contactor Ui 250 VAC Ithe 10A

    Abstract: ABS-08Pg13 interlock solenoid LC1 contactor lock solenoid E76675 EN1088 EN60947-5-1 IEC529 ABS-08
    Text: Guard Lock Safety-door Switch D4BL Protective Doors Are Locked Until Machines Completely Stop Operating Two types: • Mechanical lock/Solenoid release • Solenoid lock/Mechanical release Operation Keys: • Horizontal mounting • Vertical mounting • Vertical mounting horizontal adjustable


    Original
    EN60529, IEC529) C100-E1-2A contactor Ui 250 VAC Ithe 10A ABS-08Pg13 interlock solenoid LC1 contactor lock solenoid E76675 EN1088 EN60947-5-1 IEC529 ABS-08 PDF

    circuit diagram of door lock system

    Abstract: electronic security door lock circuit circuit diagram of door interlock system iec269 interlock solenoid LC1 contactor omron water level motor control wiring diagram pull type solenoid coils using of damper in Horizontal Output Transistor E76675
    Text: D4BL Locking Safety-Door Switch Protective Doors Are Locked Until Machines Completely Stop Operating H The switch contact is opened by a positive opening mechanism NC contacts only . Positive opening mechanism that is EN-approved is indicated by on the switch


    Original
    EN60529, IEC529) EN1088 EN60947-5-1 R9451050 circuit diagram of door lock system electronic security door lock circuit circuit diagram of door interlock system iec269 interlock solenoid LC1 contactor omron water level motor control wiring diagram pull type solenoid coils using of damper in Horizontal Output Transistor E76675 PDF

    5301-5030

    Abstract: zb omron aa63 D4NL-2CFG-B CONTACTOR fv0.5-3.7
    Text: Guard Lock Safety-door Switch D4NL Safety Interlock Switches Lead-free, Environment-friendly Design D4NL • Contains no harmful substances, such as lead, cadmium or hexavalent chromium, reducing the burden on the environment. • Models with 4-contact and 5-contact built-in Switches are


    Original
    C126-E1-03 AA-74 5301-5030 zb omron aa63 D4NL-2CFG-B CONTACTOR fv0.5-3.7 PDF

    aa63

    Abstract: D4NL-2GFG-B zb omron FV05 d4nl-1afa-b GP135 D4DL-2DFG-B D4NL-2CFG-B D4nL1DFGB
    Text: Guard Lock Safety-door Switch D4NL Safety Interlock Switches Lead-free, Environment-friendly Design D4NL • Contains no harmful substances, such as lead, cadmium or hexavalent chromium, reducing the burden on the environment. • Models with 4-contact and 5-contact built-in Switches are


    Original
    C126-E1-03 AA-74 653-D4NL-1AFA-B aa63 D4NL-2GFG-B zb omron FV05 d4nl-1afa-b GP135 D4DL-2DFG-B D4NL-2CFG-B D4nL1DFGB PDF

    circuit diagram of door lock system

    Abstract: lock solenoid m20 thermal fuse 115 solenoid lock D4nL-1DFB-B THERMAL Fuse m20 D4DL-2DFG-B G9SA-301 D4NL-2CFG-B diagram of door lock system
    Text: Guard Lock Safety-door Switch D4NL Lead-free, Environment-friendly Design • Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. • Models with 4-contact and 5-contact built-in switches are available. • Key holding force of 1,300 N min.


    Original
    C126-E1-01 75-344-7093/Fax: 1102-3M circuit diagram of door lock system lock solenoid m20 thermal fuse 115 solenoid lock D4nL-1DFB-B THERMAL Fuse m20 D4DL-2DFG-B G9SA-301 D4NL-2CFG-B diagram of door lock system PDF

    D4NL-1DFA-B

    Abstract: F502-EN2-04 D4NL-2CFG-B G158 EN1088 EN60204-1 EN60947-5-1 D4DL-2DFG-B D4nL-1bfa-B D4nL1DFGB
    Text: F502-EN2-04.book Seite 153 Dienstag, 26. Juli 2005 5:48 17 Guard Lock Safety-door Switch D4NL Lead-free, Environment-friendly Design • Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. • Models with 4-contact and 5-contact built-in switches


    Original
    F502-EN2-04 G-169 C126-E2-01-X G-170 D4NL-1DFA-B D4NL-2CFG-B G158 EN1088 EN60204-1 EN60947-5-1 D4DL-2DFG-B D4nL-1bfa-B D4nL1DFGB PDF

    D4DS-25FS

    Abstract: zb omron D4DS-15FS E76675 EN1088 EN60947-5-1 GS-ET-15 D4DS-1AFS
    Text: 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Safety-Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors H Conforms to EN TÜV standards. (positive H H H H H opening mechanism is indicated on the


    Original
    EN50047 EN1088 EN60947-5-1 R9551708 D4DS-25FS zb omron D4DS-15FS E76675 EN1088 EN60947-5-1 GS-ET-15 D4DS-1AFS PDF

    VF5120-03

    Abstract: ISO-6358 VF5220 VF5000 SGP10A VF544-03 83 fkm 592 VV5F5-20 AN400-04 VF3140
    Text: 5 Port Solenoid Valve d e c u d Re n r co e w o p w 5 0.5 w 5 5 . 1 : 2.0 onal rcuit] ng ci i v a s r e ow [With p Series VF3000 rd] [Standa W h DC Wit ote) N light enti v Con : ion t p m su  Built-in full-wave rectifier (AC)  Noise Power consumption is reduced


    Original
    VF3000 SI-8210 VF5120-03 ISO-6358 VF5220 VF5000 SGP10A VF544-03 83 fkm 592 VV5F5-20 AN400-04 VF3140 PDF

    D4DS-65FS

    Abstract: LAPP ST-PF1/2 D4DS-15FS D4DS-25FS Denki zb omron D4DS-35FS D4DS-K1 EN60947-5-1 IEC269 gG
    Text: Safety-door Switch D4DS Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double approved by TÜV and BIA. insulation Five-direction Operation Key. Approved by UL and CSA standards. Switzerland’s SUVA approval pending.


    Original
    EN60529) EN50047 EN1088 EN60947-5-1 R9551708 UL508 E76675 GS-ET-15 6010Z 6011Z D4DS-65FS LAPP ST-PF1/2 D4DS-15FS D4DS-25FS Denki zb omron D4DS-35FS D4DS-K1 EN60947-5-1 IEC269 gG PDF

    5301-5030

    Abstract: human detection sensors circuit switch juli dc motor C300 E76675 EN1088 EN60204-1 EN60947-5-1 Q300 OA-W1611
    Text: F502-EN2-04.book Seite 171 Dienstag, 26. Juli 2005 5:48 17 Guard Lock Safety-door Switch D4GL Environment-friendly Switch with Direct Opening Contacts • Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. • Slim safety-door switch with an electromagnetic lock or unlock mechanism.


    Original
    F502-EN2-04 C125-E2-01-X G-184 5301-5030 human detection sensors circuit switch juli dc motor C300 E76675 EN1088 EN60204-1 EN60947-5-1 Q300 OA-W1611 PDF

    electromagnetic lock

    Abstract: OA-W1611 lock solenoid STPF1 THERMAL Fuse m20 C300 DC-13 E76675 EN1088 EN60204-1
    Text: Guard Lock Safety-door Switch D4GL Environment-friendly Switch with Direct Opening Contacts • Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. • Slim safety-door switch with an electromagnetic lock or unlock


    Original
    C125-E1-01 75-344-7093/Fax: 1102-3M electromagnetic lock OA-W1611 lock solenoid STPF1 THERMAL Fuse m20 C300 DC-13 E76675 EN1088 EN60204-1 PDF

    UNH26

    Abstract: incandescent luminaire pendant UNHC216 UNHC232 UNHC264 UNE26 UNH182 conduit hooks
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0902-2 Name: 8L-902 8L 100: DATE: JAN 19 2006 Time: 6:00:09 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. l, Div. 2 Groups A, B, C, D UNE, UNH and UNHC Flexible Luminaire Hangers


    Original
    SYS19: CRMAIN06-0902-2 8L-902 UNH182 UNHC216 UNHC232 UNHC264 66008com UNH26 incandescent luminaire pendant UNHC216 UNHC232 UNHC264 UNE26 UNH182 conduit hooks PDF

    HBL57484IV

    Abstract: GF15G HBL24GBA512GY legrand 037 01 legrand 037 05
    Text: Hubbell Wiring Systems Delivery Systems Product Guide Table Of Contents Hubbell Raceway Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 Hubbell’s innovative Raceway Systems include a choice of steel, aluminum and non-metallic, single


    Original
    HBL750 HBL4750 H5233R08 HBL57484IV GF15G HBL24GBA512GY legrand 037 01 legrand 037 05 PDF

    ENERGY SAVING UNIT AC Diagram

    Abstract: fv0.5-3.7 BF transistor series catalog Wire AWG20 UL Red zb omron 1df diode socket head cap screw Lapp cable AC 15 Utilization category of switch D4DS-15FS
    Text: Safety-door Switch D4NS Safety Door Switches Multi-contact, Labor-saving, Environmentfriendly, Next-generation Safety-door Switch D4NS • Lineup includes three contact models with 2NC/1NO and 3NC contact forms and MBB models in addition to the previous contact forms 1NC/1NO, and 2NC.


    Original
    M12-connector ENERGY SAVING UNIT AC Diagram fv0.5-3.7 BF transistor series catalog Wire AWG20 UL Red zb omron 1df diode socket head cap screw Lapp cable AC 15 Utilization category of switch D4DS-15FS PDF

    D2TW600

    Abstract: D2TW600VC class 1 div 2 relay ETW401 relay ul 1604 ETC232 nec reed relay door bell telephone relay RS-470
    Text: D2TW600 Telephone for Hazardous Areas Applications: These single-line, fully functional electronic telephones are used: • For communication in locations which may be hazardous due to the presence of flammable gases or vapors Division 2 , and/or combustible dusts or fibers


    Original
    D2TW600 115VAC ETC232 ETW40 D2TW600 D2TW600VC class 1 div 2 relay ETW401 relay ul 1604 ETC232 nec reed relay door bell telephone relay RS-470 PDF

    legrand 037 30

    Abstract: legrand 037 87 legrand 037 40 operating instructions legrand 037 40 legrand 037 53 legrand 037 00 operating instructions legrand 036 70 Legrand data sockets LEGRAND 037 legrand 037 02
    Text: Technical catalogue ABB SACE A division of ABB S.p.A. Enclosures and Cable Systems Viale Vicenza, 61 36063 Marostica VI - Italy Tel.: +39 0424 478200 - Telefax: +39 0424 478310 http://www.abb.com 1SLC001001D0203 November ‘08 Printed in Italy 3.000 - CAL


    Original
    1SLC001001D0203 1SLC001001D0203 legrand 037 30 legrand 037 87 legrand 037 40 operating instructions legrand 037 40 legrand 037 53 legrand 037 00 operating instructions legrand 036 70 Legrand data sockets LEGRAND 037 legrand 037 02 PDF