en 50022-35
Abstract: CII Technologies relay time delay relay WD81OU-002 CII time delay relay sensitive relay EN50022-35 en50022 DIN Mounting Rail Time Delay
Text: Frequency Sensitive Relay Kilovac - WD81OU-XXX Over/Under Frequency Din Rail Mounting Function: 81 OU • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: Wilmar WD81OU frequency relays are used to provide frequency monitoring and protection to
|
Original
|
WD81OU-XXX
EN50022-35
WD81OU
en 50022-35
CII Technologies relay
time delay relay
WD81OU-002
CII time delay relay
sensitive relay
EN50022-35
en50022 DIN Mounting Rail
Time Delay
|
PDF
|
paralleling relay
Abstract: en 50022-35 dead bus RELAY kilovac 4422 datasheet CII Technologies relay
Text: Paralleling Relays Kilovac - WD25-XXX Paralleling Relay Din Rail Mounting Function: 25 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD25 paralleling relays are used to ensure that two ac circuits are synchronized. When voltage, phase
|
Original
|
WD25-XXX
EN50022-35
paralleling relay
en 50022-35
dead bus RELAY
kilovac
4422 datasheet
CII Technologies relay
|
PDF
|
4 change over relays
Abstract: over current relay en 50022-35 overcurrent relay din WD5051-3-XXX WD5051-3-002 CII Technologies relay
Text: Current Sensitive Relays Kilovac - WD5051-3-XXX Over Current Din Rail Mounting Function: 5051 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD5051-3 Series ac current sensing relays provide current monitoring and protection in ac systems
|
Original
|
WD5051-3-XXX
EN50022-35
WD5051-3
WD5051
4 change over relays
over current relay
en 50022-35
overcurrent relay din
WD5051-3-002
CII Technologies relay
|
PDF
|
CII Technologies relay
Abstract: en 50022-35 4422 datasheet relay phase control 3 phase voltage relay
Text: Phase Sequence Relays Kilovac - WD47-XXX Phase Sequence Relay Din Rail Mounting Function: 47 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • DIN EN50022-35 Operation: WD47 Series phase sequence relays are designed to monitor the correct phase rotation and loss of
|
Original
|
WD47-XXX
E58048
EN50022-35
CII Technologies relay
en 50022-35
4422 datasheet
relay phase control
3 phase voltage relay
|
PDF
|
Dual Row
Abstract: High Voltage/Current CUS Series RS Series Track Single Level Dual Level Triple Level Ground Blocks
Text: Terminal Blocks Family of Products RFI FIlters > Filtered Power Entry > Custom Filters > Terminal Blocks > Custom Terminal Blocks > Liquid Level Controllers > PCB Mount Blocks > DIN Rail TERMINAL BLOCKS > R3 4.12 2400 S. 43rd. St. Milwaukee, WI 53219 1-800-657-0853
|
Original
|
|
PDF
|
14 pin relay
Abstract: 11 pin relay Socket IEC 947-7-1 2.5 mm terminal block 10 pin relay IEC 947-7-1 terminal block 400v IEC 947-7-1 terminal block TB521 68000-10 IEC 947-7-1 400v 14 pin relay socket
Text: Curtis TERMINAL BLOCKS Curtis We Build Confidence! Filtered Power Entry RFI Filters Custom Filters Curtis Family of Products Terminal Blocks Terminal Blocks DIN Rail Liquid Level Controllers PCB Mount Blocks Custom Terminal Blocks Curtis Industries A Div. of Powers Holdings, Inc.
|
Original
|
|
PDF
|
166 relay
Abstract: en 50022-35 WD2759-002
Text: Voltage Sensitive Relays Kilovac - WD2759-XXX Over/Undervoltage Function: 27/59 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD2759 Series ac voltage sensing relays provide voltage monitoring and protection in ac systems from 50 to 400 Hz. Sensing voltages, number of
|
Original
|
WD2759-XXX
EN50022-35
WD2759
166 relay
en 50022-35
WD2759-002
|
PDF
|
Reverse Power Relay
Abstract: "reverse Power Relays" paralleling relay over current relay relay 112 SPDT DIN rail relay 166 relay 4 change over relays 9 Volt DPDT Relay double change over relay
Text: Catalog 1308242 Issued 3-03 PDF Rev. 6/07 KILOVAC WD series DIN Rail or Screw Mounted Protective Relays • • • • • • WD25 Paralleling (Synch Check) Relays WD2759 Over/undervoltage Relays WD32 Reverse Power Relays WD47 Phase Sequence Relays WD5051 Single- or Three-Phase Overcurrent Relays
|
Original
|
WD2759
WD5051
WD81OU
E58048
EN50022-35
54VDC
100-200VDC
100-140VAC.
Reverse Power Relay
"reverse Power Relays"
paralleling relay
over current relay
relay 112
SPDT DIN rail relay
166 relay
4 change over relays
9 Volt DPDT Relay
double change over relay
|
PDF
|
98/37/EC
Abstract: No abstract text available
Text: FEATURES • Complies with EU Directive for machines 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 and UL 508 • Single channel input • Output: three NO contacts and one NC contact • Automatic start or manual start modes • LED indicates power and internal relays
|
Original
|
98/37/EC,
S33/S34
S33/S34.
S33/S34
FF-SRS5924
98/37/EC
|
PDF
|
98/37/EC
Abstract: No abstract text available
Text: FEATURES • Complies with the Machinery Directive 98/37/EC, IEC 204, EN 60204, DIN VDE 0113, and UL 508 • Redundant and positive-guided contacts • Output: seven NO contacts and one NC contact • LEDs indicate channel one and two status • Mechanical life up to ten million
|
Original
|
98/37/EC,
FF-SRE3081
FF-SRE3081
FF-SRS5935
98/37/EC
|
PDF
|
en 50022-35
Abstract: 98/37/EC
Text: FEATURES • Complies with the Machinery Directive 98/37/EC, IEC 204, EN 60204, DIN VDE 0113, and UL 508 • Redundant and positive-guided contacts • Output: seven NO contacts and one NC contact • LEDs indicate channel one and two status • Mechanical life up to ten million
|
Original
|
FF-SRE3081
98/37/EC,
FF-SRS5935
FF-SRE3081
en 50022-35
98/37/EC
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FEATURES • Complies with EU Directive for machines 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 • Dual channel input • Output: two NO contacts and one NC contact • Switching current from 1mA to 7A 5 mm gold plated contacts allow low current • Automatic start or manual start modes
|
Original
|
98/37/EC,
FF-SRS5925
|
PDF
|
Honeywell Yamatake Sa 90
Abstract: Yamatake honeywell lg tv repair manual yamatake limit switch catalogue fuses manual Honeywell 38240 diagram LG TV circuits 5866A2 NFPA79 LG contactors
Text: FF-SRST Emergency Stop Module with Timer FEATURES • Complies with the Machinery Directive for 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 and UL 508 • Dual channel input • Safety outputs: two direct NO contacts, one direct NC contact, two NO delayed contacts and one NC delayed contact
|
Original
|
98/37/EC,
107058-13-EN
Honeywell Yamatake Sa 90
Yamatake honeywell
lg tv repair manual
yamatake limit switch catalogue
fuses manual
Honeywell 38240
diagram LG TV circuits
5866A2
NFPA79
LG contactors
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FEATURES • Complies with EU Directive for machines 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 • Dual channel input • Output: two NO contacts and one NC contact • Switching current from 1mA to 7A 5 µm gold plated contacts allow low current • Automatic start or manual start modes
|
Original
|
98/37/EC,
FF-SRS5925
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: FEATURES • Complies with the Machinery Directive 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 and UL 508 • Output: three NO contacts and one NC contact for AC 250 V • Gold plated, 5mm contacts allow accurate low current to PLC PLC is NOT to be used as a safety function
|
Original
|
98/37/EC,
S21/PE
S33-S34)
FF-SRS5935
|
PDF
|
emergency light circuit diagram
Abstract: automatic transfer switch circuit diagram circuit diagram of emergency light pushbutton emergency stop EMERGENCY power off pushbutton plc system for automatic door S34-S12 industrial device, s22
Text: FEATURES • Complies with the Machinery Directive 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 and UL 508 • Output: three NO contacts and one NC contact for ac 250 V • Gold plated, 5 µm contacts allow accurate low current to PLC PLC is NOT to be used as a safety function
|
Original
|
98/37/EC,
S21/PE
S33-S34)
FF-SRS5935
emergency light circuit diagram
automatic transfer switch circuit diagram
circuit diagram of emergency light
pushbutton emergency stop
EMERGENCY power off pushbutton
plc system for automatic door
S34-S12
industrial device, s22
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FEATURES • Complies with EU Directive for machines 98/37/EC, IEC 204, EN 60204-1, DIN VDE 0113 • Dual channel input • Output: six NO contacts and one NC contact • Dual voltage device 24 Vdc/ 120 Vac or 24 Vdc/230 Vac • Switching current from 1 mA to 10 A
|
Original
|
98/37/EC,
Vdc/230
S33/S34;
FF-SRS5988
|
PDF
|
98/37/EC
Abstract: No abstract text available
Text: FEATURES • Complies with EU Directive for machines 98/37/EC, IEC 204, EN 60204-1, DIN VDE 0113 • Dual channel input • Output: six NO contacts and one NC contact • Dual voltage device 24 Vdc/ 120 Vac or 24 Vdc/230 Vac • Switching current from 1 mA to 10 A
|
Original
|
98/37/EC,
Vdc/230
S33/S34;
FF-SRS5988
98/37/EC
|
PDF
|
46288
Abstract: 50035-G32 DIN IEC 60068-2-11 k DIN EN 50035 B 912 DIN 46288 IP54X
Text: Isolation Switches 911/912/913-. Description Single, two and three pole isolators to EN 60947 / IEC 60947 with toggle actuation. Designed for rail, panel or surface mounting. Options include auxiliary contacts and remote electrical disconnection. For circuit breaker versions see types 410, 520, 530.
|
Original
|
50022-35x7
57106T100/VDE
46288
50035-G32
DIN IEC 60068-2-11 k
DIN EN 50035
B 912
DIN 46288
IP54X
|
PDF
|
DIN IEC 60068-2-11 k
Abstract: 50035-G32 T100 46288 082ac
Text: High Performance Thermal-Magnetic Circuit Breakers 410/520/530-. Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism and toggle actuation S-type TM CBE to EN 60 934; also to EN 60 947 .
|
Original
|
60947/EN
DIN IEC 60068-2-11 k
50035-G32
T100
46288
082ac
|
PDF
|
Dual Level
Abstract: 6204000 6204010 6204100 6204130 6204200 Screw Connection Dual Level
Text: Screw Connection Single Level 6504000 4/15 Mini Feed Through • Plastic Body: Polyamide 6.6 • Internal Bus: Nickel-plated brass • Clamp: Hardened steel, electroplated with zinc yellow-chromated • Screws: Steel, zinc-plated and yellow-chromated • Marking: 4 slots on both
|
Original
|
12-Pole
Dual Level
6204000
6204010
6204100
6204130
6204200
Screw Connection Dual Level
|
PDF
|
Untitled
Abstract: No abstract text available
Text: High Performance Thermal-Magnetic Circuit Breakers 410/520/530-. Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism and toggle actuation S-type TM CBE to EN 60 934; also to EN 60 947 .
|
Original
|
60947/EN
|
PDF
|
IPC-D-275 Design standard for Rigid Printed Boards and Rigid Printed Board Assemblies
Abstract: No abstract text available
Text: Terminal Blocks BLOCKS Innovative Engineering Solutions Contents Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 BARRIER STYLE TERMINAL BLOCKS ] Single Row SE/SEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
|
Original
|
|
PDF
|
B25355
Abstract: DIN 433 B25355-L1147-K004 ISO 4035 B25355-L2166-K001 siemens rs 248 Bolt Torque siemens B25355-J2405-K001 capacitor 2200 uF siemens B25355L2326K004
Text: MP DC Capacitors Smoothing, Supporting, Discharge B 25 355 High peak-current capability Wide capacitance and voltage range Construction ● Self-healing ● Paper dielectric ● Oil and hard-wax-impregnated tubular windings no PCB ● Metal-sprayed end faces ensure
|
Original
|
B25355-G6405-K001
B25355
DIN 433
B25355-L1147-K004
ISO 4035
B25355-L2166-K001
siemens rs 248
Bolt Torque siemens
B25355-J2405-K001
capacitor 2200 uF siemens
B25355L2326K004
|
PDF
|