Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DOL STARTER Search Results

    DOL STARTER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SH7124-Starter-Kit Renesas Electronics Corporation Renesas Starter Kit for SH7124 Visit Renesas Electronics Corporation
    SH7269-Starter-Kit-Plus Renesas Electronics Corporation Renesas Starter Kit+ for SH7269 Visit Renesas Electronics Corporation
    SH7286-Starter-Kit Renesas Electronics Corporation Renesas Starter Kit for SH7286 Visit Renesas Electronics Corporation
    SH7211-Starter-Kit Renesas Electronics Corporation Renesas Starter Kit for SH7211 Visit Renesas Electronics Corporation
    SH7216-Starter-Kit-Plus Renesas Electronics Corporation Renesas Starter Kit+ for SH7216 Visit Renesas Electronics Corporation

    DOL STARTER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    140M-C-AFA11

    Abstract: 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16
    Text: MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE DOL-Starter Overload Protection Short Circuit Protection DOL-Starter Overload Protection PROTECTION FOR AC AND DC MOTORS • The Bulletin 193-K thermal


    Original
    PDF 193-K 100-K 140-M MCS-SG001A-EN-P 140M-C-AFA11 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16

    dol starter

    Abstract: IP657 schneider motor starter electric motor starter LJ7K06Q706 information of dol starter IEC 60439 ac motor starter
    Text: Product data sheet Characteristics LJ7K06Q706 enclosed DOL starter - TeSys LJ7-K - 1.1.6 A - coil 380 V AC Range of product TeSys Device short name LJ7K Product or component type Enclosed DOL starter with integral transformer Contactor application Motor control


    Original
    PDF LJ7K06Q706 98/37/CE IP657 dol starter schneider motor starter electric motor starter LJ7K06Q706 information of dol starter IEC 60439 ac motor starter

    wiring diagram dol motor starter

    Abstract: wiring 3 phase dol starter with overload diagram wiring diagram dol starter DOL wiring diagram motor DOL starter wiring diagram wiring start dol DOL starter wiring diagram motor dol motor starter wiring diagram wiring diagram start dol three-phase 3kw ac motor speed control circuit diagram
    Text: Technical Specification English Powerbrake PBP Range DC Injection Production Brakes for existing DOL Starters Powerbrake PBP is a range of self-contained D.C. Injection Production Brakes for use with an existing DOL Starter. It is suitable for 400V three-phase motors from 3.0 to 75 kW.


    Original
    PDF 012263/3E/302 wiring diagram dol motor starter wiring 3 phase dol starter with overload diagram wiring diagram dol starter DOL wiring diagram motor DOL starter wiring diagram wiring start dol DOL starter wiring diagram motor dol motor starter wiring diagram wiring diagram start dol three-phase 3kw ac motor speed control circuit diagram

    IEC 60439-1

    Abstract: IP657 schneider thermal overload relay LE2D09V7 schneider motor starter electric motor starter 3 Kw ac motor control
    Text: Product data sheet Characteristics LE2D09V7 enclosed DOL reversing starter - TeSys LE2-D - 9 A - coil 400 V AC Range of product TeSys Device short name LE2D Product or component type Enclosed DOL starter Motor starter type Reversing Motor power kW 4 kW at 380/400 V AC 50/60 Hz


    Original
    PDF LE2D09V7 IP657 IEC 60439-1 schneider thermal overload relay LE2D09V7 schneider motor starter electric motor starter 3 Kw ac motor control

    star delta starter 4.0 kw to 100 kw

    Abstract: STAR DELTA STARTER star delta starter abb single phase dol motor starter three phase star delta starter star delta motor starter starter voltage 75 kw three phase dol motor starter starter for 1.5 hp motors 2301P
    Text: Control - DC Injection Brakes Powerbrake Production - DOL Used to increase the production output on machines which would normally take a long period of time to come to rest after the stop button has been pressed. Available in three formats with DOL starter, with Star Delta starter and without starter for use with existing


    Original
    PDF PBP11-400 PBPS11-400 PBP15-400 PBPS15-400 PBP22-400 PBPS22-400 PBP30-400 PBP37-400 PBP45-400 PBP55-400 star delta starter 4.0 kw to 100 kw STAR DELTA STARTER star delta starter abb single phase dol motor starter three phase star delta starter star delta motor starter starter voltage 75 kw three phase dol motor starter starter for 1.5 hp motors 2301P

    IEC 947-4-1

    Abstract: abb dol starter ip65 abb dc motor full load current of a 11Kw motor TA25DU19 TA25DU25 1SAZ211201R1023 abb TA25DU25 1SAZ211201R1051 1SAZ211201R1033
    Text: DOL Starters with Isolator Type EXE2DI Metal Enclosure to IP65 Installation Instructions fb`VQTJQJN Issue 10 = 06.012228.10E 0808 1. Remove cover from starter by releasing catches with a screwdriver. 2. Select and fit Overload see ratings chart below . 3.


    Original
    PDF

    Starting Current 7.5KW Motor 440v

    Abstract: 7.5KW 3 phase motor 440v 3 phase, 415v and 11 kw induction motor 380V 415v 15kw motor 0.5 hp 3-PHASE induction motor 380v motor overload protection 15 KW induction motor 440v 3phase 220v motor overload protection contactor and overload start stop 3 phase motor start with contactor
    Text: B17064 Issued March 1994 Directonline DOL starters 0.5to10hp415VacProtectedtoIP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated enclosure environmentally protected to IP66. The


    Original
    PDF B17064 415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V Starting Current 7.5KW Motor 440v 7.5KW 3 phase motor 440v 3 phase, 415v and 11 kw induction motor 380V 415v 15kw motor 0.5 hp 3-PHASE induction motor 380v motor overload protection 15 KW induction motor 440v 3phase 220v motor overload protection contactor and overload start stop 3 phase motor start with contactor

    full load current of a 11Kw motor

    Abstract: DuoSoft.N15 MTE power control relay ac power control applications 400v 16a DuoSoft dc motor soft start AC Motor soft start 3 ph AC Motor speed and soft start mte overload AC Motor speed and soft start
    Text: Technical Specification I 2 DuoSoft.N7 DuoSoft.N11 DuoSoft.N15 Three-phase Soft Starters DuoSoft.N7 DuoSoft.N11 & DuoSoft.N15 are compact low cost soft starters for three-phase motors up to 7.5, 11 & 15 kW respectively. They overcome the disadvantages of the usual DOL direct-on-line


    Original
    PDF 012132/2E/1098 full load current of a 11Kw motor DuoSoft.N15 MTE power control relay ac power control applications 400v 16a DuoSoft dc motor soft start AC Motor soft start 3 ph AC Motor speed and soft start mte overload AC Motor speed and soft start

    wiring diagram dol motor starter

    Abstract: 3phase winding data 3.7 kw to 110 kw DOL wiring diagram motor 5.5KW motor wiring diagram DOL starter wiring diagram motor dol motor starter wiring diagram 400v 3KW motor circuit 11KW 3 phase motor 5.5KW motor 7.5KW motor resistance
    Text: PBP3-400 Description 3.0 kW complete dc injection brake unit without starter, for production braking PBP is a range of self-contained D.C. Injection Production Brakes for use with an existing DOL Starter. It is suitable for 400V three-phase motors from 3.0 to 75 kW.


    Original
    PDF PBP3-400 100FE 140FE 180FE 225FE wiring diagram dol motor starter 3phase winding data 3.7 kw to 110 kw DOL wiring diagram motor 5.5KW motor wiring diagram DOL starter wiring diagram motor dol motor starter wiring diagram 400v 3KW motor circuit 11KW 3 phase motor 5.5KW motor 7.5KW motor resistance

    wiring diagram dol motor starter

    Abstract: dol starter K2-09A10 starter for 1.5 hp motors K2-16A10 k2-09a10 wiring diagram START-STOP wiring diagram contactor wiring start dol contactor coils 415v
    Text: DOL Starters P1M ❚ Up to 7.5kW ❚ IP65 enclosure ❚ Start-Stop pushbuttons ❚ Hand-Off-Auto selector ❚ Wired to accept overload ❚ Indicator ❚ Anti-condensation heater Options and ordering codes P1 Series M T P1 M20 x 1.5 conduit knockouts Start-stop pushbuttons


    Original
    PDF 20-240V 80-415V P1M/03/03 K2-09A10 U1216E K2-16A10 15/hour U1216E0 wiring diagram dol motor starter dol starter K2-09A10 starter for 1.5 hp motors K2-16A10 k2-09a10 wiring diagram START-STOP wiring diagram contactor wiring start dol contactor coils 415v

    PILOT LIGHT 230V

    Abstract: dol starter 84EXE0D-OL
    Text: Control - Direct-on-Line Starters IP66 Plastic Enclosure Three Phase 400v up to 7.5kW - 400v coil • Smoothly styled modern IP66 enclosed DOL starter, with generous cabling space for easy installation. Combined contactor/overload assembly can be unclipped from DIN rail to ease installation.


    Original
    PDF 82EXE0D-OL 122EXE0D-OL 182EXE0D-OL PILOT LIGHT 230V dol starter 84EXE0D-OL

    3.7 KW induction motor 440v 3phase

    Abstract: contactor and overload start stop VDE0660 3 phase, 415v and 15 kw motor 1 KW induction motor 440v 3phase 3 phase squirrel cage induction motor remote control circuit of a phase induction motor 0.5 hp 3-PHASE induction motor bs5424 3 phase, 415v and 11 kw induction motor
    Text: Issued November 1990 B11044 Direct on line dol starters 0.5 to 10hp415Vac Features l Protected to IP54 l Robust sheet steel enclosure l 3-pole contactor to BS5424; IEC158-1 and VDE0660 l 20mm conduit entries. Robust direct on line ac starters complying with


    Original
    PDF B11044 415Vac BS4941; IEC292 VDE0660. BS5424; IEC158-1 VDE0660 220/240V 380/440V 3.7 KW induction motor 440v 3phase contactor and overload start stop 3 phase, 415v and 15 kw motor 1 KW induction motor 440v 3phase 3 phase squirrel cage induction motor remote control circuit of a phase induction motor 0.5 hp 3-PHASE induction motor bs5424 3 phase, 415v and 11 kw induction motor

    7.5KW 3 phase motor 440v

    Abstract: Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor IEC158 VDE0660 11 KW 3-phase motor weight
    Text: Issued March 1994 017-064 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated


    Original
    PDF 415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V 7.5KW 3 phase motor 440v Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor 11 KW 3-phase motor weight

    Starting Current 7.5KW Motor 440v

    Abstract: 7.5KW 3 phase motor 440v contactor and overload start stop 1 KW induction motor 440v 3phase OVERLOAD RELAY bs5424 15 KW induction motor 440v 3phase 0.5 hp 3-PHASE induction motor 440V 50HZ dol starter
    Text: Issued March 1999 232-4493 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated


    Original
    PDF 415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V Starting Current 7.5KW Motor 440v 7.5KW 3 phase motor 440v contactor and overload start stop 1 KW induction motor 440v 3phase OVERLOAD RELAY bs5424 15 KW induction motor 440v 3phase 0.5 hp 3-PHASE induction motor 440V 50HZ dol starter

    wiring diagram dol motor starter

    Abstract: contactor coils 415v dol starter K2-09A10 contactor coils 415v k2-09a10 wiring diagram contactor single phase DOL starter wiring k2-09a10 wiring diagram k2-09a10 wiring overload contactor
    Text: DOL Starters • Up to 7.5kW ■ IP65 enclosure ■ Start-Stop pushbuttons ■ Hand-Off-Auto selector ■ Wired to accept overload ■ Indicator ■ Anti-condensation heater P1M PRODUCT SPECIFICATION OR TO ORDER Options and ordering codes P1 Series P1 M20 x 1.5 conduit


    Original
    PDF 20-240V 80-415V K2-09A10 K2-16A10 U1216E 15/hour wiring diagram dol motor starter contactor coils 415v dol starter K2-09A10 contactor coils 415v k2-09a10 wiring diagram contactor single phase DOL starter wiring k2-09a10 wiring diagram k2-09a10 wiring overload contactor

    telemecanique contactor catalogue

    Abstract: telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1
    Text: Issued November 1991 012-570 Data Pack B Data Sheet Direct on line DOL starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and


    Original
    PDF BS4941 2xPE16 telemecanique contactor catalogue telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1

    EATON

    Abstract: 21MSULK star delta motor starter 404RDMP 22MSUL 21MSU2SK 28ARD1X 428ALCFP 22MSU 21MSUL
    Text: ADS8 Wall Chart 22/11/06 5:54 pm Page 1 ADS8 Motor starters and overload relays 9kW DOL starter without switch disconnect 25kW Star Delta starter without switch disconnect • IP 54 metalclad surface mounting enclosure, less overload relay • IP 65 moulded surface mounting enclosure, less overload relay


    Original
    PDF 28ADSM1X 50Hz1 48ADSM1X 28SDA2X18 2812004VCOA 4812004VCOA 2825004VCOA 4825004VCOA EATON 21MSULK star delta motor starter 404RDMP 22MSUL 21MSU2SK 28ARD1X 428ALCFP 22MSU 21MSUL

    telemecanique contactor catalogue

    Abstract: telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 telemecanique contactor LC1 Telemecanique MOTOR STARTER telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE
    Text: Issued March 1997 232-3591 Data Pack B Data Sheet Direct on line DOL starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and


    Original
    PDF BS4941 circula135 2xPE16 telemecanique contactor catalogue telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 telemecanique contactor LC1 Telemecanique MOTOR STARTER telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE

    telemecanique contactor catalogue

    Abstract: telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE "IEC 292-1"
    Text: Issued November 1991 B12570 Direct on line DOL starters TelemecaniqueÔd2Õ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique Ôd2Õ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and VDE 0660. RS stock no.


    Original
    PDF B12570 BS4941 corr32 2xPE13 2xPE16 telemecanique contactor catalogue telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE "IEC 292-1"

    VDE0660

    Abstract: Starting Current 7.5KW Motor 440v vde-0660 380V 415v motor 3 phase, 415v and 11 kw induction motor bs5424 IEC158-1 IEC158 OVERLOAD RELAY 1 KW induction motor 440v 3phase
    Text: Issued November 1990 011-044 Data Pack B Direct on line dol starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed


    Original
    PDF 415Vac BS4941; IEC292 VDE0660. 220/240V 380/440V BS5424; IEC158-1 VDE0660 VDE0660 Starting Current 7.5KW Motor 440v vde-0660 380V 415v motor 3 phase, 415v and 11 kw induction motor bs5424 IEC158 OVERLOAD RELAY 1 KW induction motor 440v 3phase

    VDE0660

    Abstract: 380V 415v 15kw motor vde-0660 3 phase, 415v and 11 kw induction motor 15 KW induction motor 440v 3phase Starting Current 7.5KW Motor 440v IEC292 380V 415v motor 3 phase, 415v and 37 kw motor single phase dol motor starter
    Text: Issued March 1997 232-3355 Data Pack B Direct on line dol starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed


    Original
    PDF 415Vac BS4941; IEC292 VDE0660. 220/240V 380/440V BS5424; IEC158-1 VDE0660 VDE0660 380V 415v 15kw motor vde-0660 3 phase, 415v and 11 kw induction motor 15 KW induction motor 440v 3phase Starting Current 7.5KW Motor 440v 380V 415v motor 3 phase, 415v and 37 kw motor single phase dol motor starter

    single phase DOL starter wiring

    Abstract: abb dol starter wiring to motor 3 phase, 415v and 37 kw motor 326-166 bobina de encendido abb dol starter wiring 32M40 AC11 dol starter connections 380V 415v motor
    Text: Issued / Herausgegeben / Publicado / Publication Publicatto / Udgivet / Afgegeven / Utgiven 04/2002 V8721 0.5 to 10hp 415V Direct on Line Starter Direktstarter, 0,5-10 PS, 415 V Instruction Leaflet Bedienungsanleitung Hojas de instrucciones Feuille d’instructions


    Original
    PDF V8721 single phase DOL starter wiring abb dol starter wiring to motor 3 phase, 415v and 37 kw motor 326-166 bobina de encendido abb dol starter wiring 32M40 AC11 dol starter connections 380V 415v motor

    wiring diagram STAR DELTA motor starter

    Abstract: 3 phase motor soft starter circuit diagram 3 phase induction motor soft starter circuit diagram wiring diagram star delta starter 3 phase motor soft starter diagram star delta starter diagram 3 phase 75kW motor soft circuit diagram thyristor motor speed control circuit Diagram of motor speed control 115V AC 3 phase motor starter circuit diagram
    Text: Issued March 1994 B17525 Electronic soft starters Minisoft Supplied to RS by MTE Ltd RS stock numbers 188-914, 188-920, 188-936, 188-942 Introduction Minisoft is a range of low cost soft starters and controllers for 3-phase motors up to 7.5kW. Each phase of the motor is fully controlled during the starting


    Original
    PDF B17525 380/415V 50-60Hz wiring diagram STAR DELTA motor starter 3 phase motor soft starter circuit diagram 3 phase induction motor soft starter circuit diagram wiring diagram star delta starter 3 phase motor soft starter diagram star delta starter diagram 3 phase 75kW motor soft circuit diagram thyristor motor speed control circuit Diagram of motor speed control 115V AC 3 phase motor starter circuit diagram

    star delta FORWARD REVERSE STARTER

    Abstract: T25DU hp 15 star delta control 3phase star delta starter 4.0 kw to 100 kw wiring 3 phase dol starter with emergency stop magnetic Contactor abb a9-30-10 ABB t25du star delta starter wiring star delta FORWARD REVERSE STARTER WIRING IEC947-4-1
    Text: Control Overview 4 Contents Direct on Line Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/2 - 4/3 Direct on Line Starters + Isolator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/4


    Original
    PDF M10/10 1SNA390105R0500 1SNA390102R0200 1SNA390103R0300 1SNA390106R0600 RC610 1SNA390107R0700 100mm star delta FORWARD REVERSE STARTER T25DU hp 15 star delta control 3phase star delta starter 4.0 kw to 100 kw wiring 3 phase dol starter with emergency stop magnetic Contactor abb a9-30-10 ABB t25du star delta starter wiring star delta FORWARD REVERSE STARTER WIRING IEC947-4-1