Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EXPLOSION PROOF CABLE GLAND Search Results

    EXPLOSION PROOF CABLE GLAND Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SF-SFPP2EPASS-005 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-005 5m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (16.4 ft) Datasheet
    SF-SFPP2EPASS-001 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-001 1m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (3.3 ft) Datasheet
    AV-DPMDPM0000-001 Amphenol Cables on Demand Amphenol AV-DPMDPM0000-001 1m DisplayPort Cable - Amphenol DisplayPort 1.1 Certified Cable (3.3ft) 1m (3.3') Datasheet
    SF-SFPP2EPASS-007 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-007 7m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (23 ft) Datasheet
    SF-SFPP2EPASS-002 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-002 2m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (6.6 ft) Datasheet

    EXPLOSION PROOF CABLE GLAND Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    M20-Exe

    Abstract: No abstract text available
    Text: Product catalogue | Enclosures | cable entries | Explosion-proof cable glands | Brass cable glands, MSN General ordering data Order No. Part designation Version EAN Qty. 1816790000 VG M20-Exe/d MSN 3-8 Cable gland, Brass, External thread: M 20 x 1.5 4032248308774


    Original
    M20-Exe/d EC000441 27-14aterial M25-Exe/d M20-Exe PDF

    SG2A

    Abstract: No abstract text available
    Text: Delayed Action Receptacles Delayed Action Receptacles EFS and DA Accessories Cable Bushings For Explosion Proof Plugs & Connectors To order non-standard bushing, add cable bushing number to end of catalog number. This is furnished at no additional cost at


    Original
    4466/SG3 F19054C F19054D F24853C F24853D SG2A PDF

    Untitled

    Abstract: No abstract text available
    Text: Cable Glands SKINTOP cable glands polyamide metric SKINTOP Explosion proof SKINTOP K-M ATEX blue / SKINTOP KR-M ATEX blue SKINTOP K-M ATEX blue • Benefits SKINTOP K-M ATEX blue ▯ Degree of protection ▯ Dynamic strain stability ▯ High strain relief


    Original
    PDF

    EN5014

    Abstract: BS5501 connector 608 series
    Text: Amphenol AFC Series Explosion Proof Connector A range of EExd approved connectors available in Aluminium, Stainless Steel & Nickel Aluminium Bronze. The connectors are available in patterns from 1 to 128 contacts and rated up to 140 amps with solder style contacts. For easy cost effective cable termination, both the free and fixed connectors utilise


    Original
    PDF

    EN 10204 3.1

    Abstract: Neozed RHDE4000 IMB6 EBS862 ptc temperature sensor motor winding THERMAL Fuse m20 EBN861 RHDE4000-40 CA14 c&k
    Text: Data Sheet 10/68-1.94-EN Electrical Part Turn Actuator RHDE4000 Contrac Pos: 1 /Titelblätter / Copyright/DB/Aktorik/Antriebe/Schwenkantriebe, Ex/El. Schwenkantrieb RHDE4000 (Contrac) @ 6\mod_1169192104031_3101.doc @ 61566 For continuous positioning In Explosion Proof design,


    Original
    94-EN RHDE4000 3KXE111011R1001 94-EN EN 10204 3.1 Neozed RHDE4000 IMB6 EBS862 ptc temperature sensor motor winding THERMAL Fuse m20 EBN861 RHDE4000-40 CA14 c&k PDF

    CRV420

    Abstract: cei 20-11 LA 7683 A EYS 07 RE41 DIN EN 50014 STANDARD HEPR electrical sealing Compound RE31 RE42
    Text: AD VIGANO Explosion Proof Electrical Equipment SEZIONE 1 SECTION 1 15 AD VIGANO Explosion Proof Electrical Equipment EN 50.014 EN 50.018 TUBO RIGIDO TIPO CONDUIT IN ACCIAIO - STEEL RIGID CONDUIT AD UNI 7683 I tubi conduit per l'infilaggio dei conduttori sono realizzati in acciaio Fe 360, galvanizzati sia all'interno sia all'esterno


    Original
    PDF

    CDQ2N52

    Abstract: 2 MHZ ULTRASONIC transducers CDK1N52
    Text: Technical Specification FLUXUS F70x Liquid Ultrasonic Flowmeter for Permanent Installation Designed for wall mounting or installation in 19'' rack systems Features • Precise bi-directional and highly dynamic flow measurement with the non-intrusive clamp-on technology


    Original
    PDF

    a3202

    Abstract: No abstract text available
    Text: RP2E Compact pressure switch Explosion proof Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Resistant to accidental overpressure „„ Explosion proof Hazardous areas 1, 2, 21, 22


    Original
    2006/95/EC 97/23/EC 94/9/EC a3202 PDF

    Ashcroft 825A022

    Abstract: Presure sensor
    Text: Model A2X Explosion/Flame Proof Pressure Transmitter APPLICATIONS: Oil field equipment, upstream oil and gas production, natural gas compression and transfer control, alternative energy projects Temperature Effects: –20 to +85°C –4 to 185°F • 1.0% of Span for .25% Accuracy Class


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: RT2E Compact temperature switch Explosion proof Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Light weight „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications „„Power generation safety equipment


    Original
    2006/95/EC 94/9/EC PDF

    Untitled

    Abstract: No abstract text available
    Text: RTNE3 - RTAE3 Industrial temperature switch, direct mounting explosion proof Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications


    Original
    2006/95/EC 94/9/EC Stai35 PDF

    Untitled

    Abstract: No abstract text available
    Text: RPPE6 - RPPE8 Industrial pressure switch, explosion proof with high overpressure resistance Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Overpressure up to 100 bar „„ Explosion proof Hazardous areas 1, 2, 21, 22


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: RPPE4 Industrial pressure switch, explosion proof with high overpressure resistance Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Overpressure up to 100 bar „„ Explosion proof Hazardous areas 1, 2, 21, 22


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: RDE6 Differential pressure switch, explosion proof for variable static pressure Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Static pressure max. 20 bar „„ No influence of the static pressure on the setpoint


    Original
    2006/95/EC PDF

    Untitled

    Abstract: No abstract text available
    Text: RDE5 Differential pressure switch, explosion proof for high static pressure Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ High static pressure „„ Explosion proof Hazardous areas 1, 2, 21, 22


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: RDE4 - RDE8 Differential pressure switch, explosion proof Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications „„Power generation safety equipment


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: RTNE4 - RTAE4 Industrial temperature switch with capillary, explosion proof Main Features „„ Excellent repeatability „„ Dead band adjustment for regulation „„ Fix dead band for control and alarm „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: RPPE3 - RPPE7 Industrial pressure switch explosion proof Main Features „„ Excellent repeatability „„ Fix dead band for control and alarm „„ Dead band adjustment for regulation „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications „„Power generation safety equipment


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: MCE Capsule pressure gauges with electrical contacts explosion proof BA87 For corrosive fluids and atmospheres LCIE 03 ATEX 6125X CE 0081 II 2 G et D EEx d IIC T6 ou T5 Hazardous areas: 1, 2, 21, 22 Based upon the MCX gauges Ø 150 of which they share all characteristics, they


    Original
    6125X UK/04-2007 PDF

    Pt 100 RTD Siemens

    Abstract: circuit diagram for profibus connector siemens Siemens pt100 temperature transmitter Siemens PT100 temperature sensor RTD Thermocouple Type L Thermocouple Type g Siemens PT100 temperature sensor type s thermocouple siemens Pt100 3 wire PT-100 temperature transducer
    Text: TF 212 / TF 212-Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 100 RTD , thermocouples, 1 or 2 independent channels 10/11-8.70 EN P R O F PROCESS FIELD BUS B U S • Input – – – – Resistance thermometer (2, 3, 4-wire method) Thermocouples


    Original
    212-Ex Pt 100 RTD Siemens circuit diagram for profibus connector siemens Siemens pt100 temperature transmitter Siemens PT100 temperature sensor RTD Thermocouple Type L Thermocouple Type g Siemens PT100 temperature sensor type s thermocouple siemens Pt100 3 wire PT-100 temperature transducer PDF

    JUPITER m series connector

    Abstract: 8810 series JUPITER connector JUPITER MS series JUPITER marking 8810 JUPITER M series connector M series FCI Jupiter
    Text: JUPITER 8810 ADF Series Description Applications ț Explosion proof connectors for use in hazardous areas - screw locking system ț Explosion proof certification by B.A.S.E.E.F.A. British Approvals Service for Electrical Equipment in Flamable Atmosphere


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: MaxGard MaxGard Interconnection Systems 30-400/600 Amp, 30-200A Load Breaking Maximum 600 VAC /250 VDC Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion Proof Interlocked Receptacles Benefits Russellstoll® builds a variety of benefits into one plug,


    Original
    0-200A E57324, E68085, E123752. LR14096. MIL-STD-105 D2565: PR41983; PDF

    BS2779 BSP THREAD

    Abstract: IEC60079-14 EX-35-B-1-0-20-M20 M32 nylon cable gland 602 GB Series AMPHENOL dts01 galvanised conduit hazardous area ZP-C-2520-12 Radsok Amphenol Radsok
    Text: Amphenol Cable Glands and Cord Grips 12-055 Amphenol Table of Contents Introduction Amphenol® Cable Glands Page Number 1 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30 8-9 EX-35 10-11 EX-40 12-13 EX-45 14-15 EE-RG 16-17


    Original
    EX-20 EX-25 EE-30 EX-35 EX-40 EX-45 EX-50 EX-55 EX-60 EX-65 BS2779 BSP THREAD IEC60079-14 EX-35-B-1-0-20-M20 M32 nylon cable gland 602 GB Series AMPHENOL dts01 galvanised conduit hazardous area ZP-C-2520-12 Radsok Amphenol Radsok PDF

    Untitled

    Abstract: No abstract text available
    Text: Flow module For the connection of intrinsically safe flow sensors HART device with current and transistor outputs FMX-IM-2UPLi63X • ATEX category II 1 G, Ex-zone 0 ■ ATEX category II (1) D, Ex-zone 20 ■ For Ex ia resp. Ex ib sensors ■ Analog output for flow


    Original
    FMX-IM-2UPLi63X 30VDC 2013-07-13T20 D-45472 PDF