M20-Exe
Abstract: No abstract text available
Text: Product catalogue | Enclosures | cable entries | Explosion-proof cable glands | Brass cable glands, MSN General ordering data Order No. Part designation Version EAN Qty. 1816790000 VG M20-Exe/d MSN 3-8 Cable gland, Brass, External thread: M 20 x 1.5 4032248308774
|
Original
|
M20-Exe/d
EC000441
27-14aterial
M25-Exe/d
M20-Exe
|
PDF
|
SG2A
Abstract: No abstract text available
Text: Delayed Action Receptacles Delayed Action Receptacles EFS and DA Accessories Cable Bushings For Explosion Proof Plugs & Connectors To order non-standard bushing, add cable bushing number to end of catalog number. This is furnished at no additional cost at
|
Original
|
4466/SG3
F19054C
F19054D
F24853C
F24853D
SG2A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Cable Glands SKINTOP cable glands polyamide metric SKINTOP Explosion proof SKINTOP K-M ATEX blue / SKINTOP KR-M ATEX blue SKINTOP K-M ATEX blue • Benefits SKINTOP K-M ATEX blue ▯ Degree of protection ▯ Dynamic strain stability ▯ High strain relief
|
Original
|
|
PDF
|
EN5014
Abstract: BS5501 connector 608 series
Text: Amphenol AFC Series Explosion Proof Connector A range of EExd approved connectors available in Aluminium, Stainless Steel & Nickel Aluminium Bronze. The connectors are available in patterns from 1 to 128 contacts and rated up to 140 amps with solder style contacts. For easy cost effective cable termination, both the free and fixed connectors utilise
|
Original
|
|
PDF
|
EN 10204 3.1
Abstract: Neozed RHDE4000 IMB6 EBS862 ptc temperature sensor motor winding THERMAL Fuse m20 EBN861 RHDE4000-40 CA14 c&k
Text: Data Sheet 10/68-1.94-EN Electrical Part Turn Actuator RHDE4000 Contrac Pos: 1 /Titelblätter / Copyright/DB/Aktorik/Antriebe/Schwenkantriebe, Ex/El. Schwenkantrieb RHDE4000 (Contrac) @ 6\mod_1169192104031_3101.doc @ 61566 For continuous positioning In Explosion Proof design,
|
Original
|
94-EN
RHDE4000
3KXE111011R1001
94-EN
EN 10204 3.1
Neozed
RHDE4000
IMB6
EBS862
ptc temperature sensor motor winding
THERMAL Fuse m20
EBN861
RHDE4000-40
CA14 c&k
|
PDF
|
CRV420
Abstract: cei 20-11 LA 7683 A EYS 07 RE41 DIN EN 50014 STANDARD HEPR electrical sealing Compound RE31 RE42
Text: AD VIGANO Explosion Proof Electrical Equipment SEZIONE 1 SECTION 1 15 AD VIGANO Explosion Proof Electrical Equipment EN 50.014 EN 50.018 TUBO RIGIDO TIPO CONDUIT IN ACCIAIO - STEEL RIGID CONDUIT AD UNI 7683 I tubi conduit per l'infilaggio dei conduttori sono realizzati in acciaio Fe 360, galvanizzati sia all'interno sia all'esterno
|
Original
|
|
PDF
|
CDQ2N52
Abstract: 2 MHZ ULTRASONIC transducers CDK1N52
Text: Technical Specification FLUXUS F70x Liquid Ultrasonic Flowmeter for Permanent Installation Designed for wall mounting or installation in 19'' rack systems Features • Precise bi-directional and highly dynamic flow measurement with the non-intrusive clamp-on technology
|
Original
|
|
PDF
|
a3202
Abstract: No abstract text available
Text: RP2E Compact pressure switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Resistant to accidental overpressure Explosion proof Hazardous areas 1, 2, 21, 22
|
Original
|
2006/95/EC
97/23/EC
94/9/EC
a3202
|
PDF
|
Ashcroft 825A022
Abstract: Presure sensor
Text: Model A2X Explosion/Flame Proof Pressure Transmitter APPLICATIONS: Oil field equipment, upstream oil and gas production, natural gas compression and transfer control, alternative energy projects Temperature Effects: –20 to +85°C –4 to 185°F • 1.0% of Span for .25% Accuracy Class
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RT2E Compact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2, 21, 22 Applications Power generation safety equipment
|
Original
|
2006/95/EC
94/9/EC
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RTNE3 - RTAE3 Industrial temperature switch, direct mounting explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Explosion proof Hazardous areas 1, 2, 21, 22 Applications
|
Original
|
2006/95/EC
94/9/EC
Stai35
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RPPE6 - RPPE8 Industrial pressure switch, explosion proof with high overpressure resistance Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Overpressure up to 100 bar Explosion proof Hazardous areas 1, 2, 21, 22
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RPPE4 Industrial pressure switch, explosion proof with high overpressure resistance Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Overpressure up to 100 bar Explosion proof Hazardous areas 1, 2, 21, 22
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RDE6 Differential pressure switch, explosion proof for variable static pressure Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Static pressure max. 20 bar No influence of the static pressure on the setpoint
|
Original
|
2006/95/EC
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: RDE5 Differential pressure switch, explosion proof for high static pressure Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm High static pressure Explosion proof Hazardous areas 1, 2, 21, 22
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RDE4 - RDE8 Differential pressure switch, explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Explosion proof Hazardous areas 1, 2, 21, 22 Applications Power generation safety equipment
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RTNE4 - RTAE4 Industrial temperature switch with capillary, explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Explosion proof Hazardous areas 1, 2, 21, 22 Applications
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RPPE3 - RPPE7 Industrial pressure switch explosion proof Main Features Excellent repeatability Fix dead band for control and alarm Dead band adjustment for regulation Explosion proof Hazardous areas 1, 2, 21, 22 Applications Power generation safety equipment
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MCE Capsule pressure gauges with electrical contacts explosion proof BA87 For corrosive fluids and atmospheres LCIE 03 ATEX 6125X CE 0081 II 2 G et D EEx d IIC T6 ou T5 Hazardous areas: 1, 2, 21, 22 Based upon the MCX gauges Ø 150 of which they share all characteristics, they
|
Original
|
6125X
UK/04-2007
|
PDF
|
Pt 100 RTD Siemens
Abstract: circuit diagram for profibus connector siemens Siemens pt100 temperature transmitter Siemens PT100 temperature sensor RTD Thermocouple Type L Thermocouple Type g Siemens PT100 temperature sensor type s thermocouple siemens Pt100 3 wire PT-100 temperature transducer
Text: TF 212 / TF 212-Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 100 RTD , thermocouples, 1 or 2 independent channels 10/11-8.70 EN P R O F PROCESS FIELD BUS B U S • Input – – – – Resistance thermometer (2, 3, 4-wire method) Thermocouples
|
Original
|
212-Ex
Pt 100 RTD Siemens
circuit diagram for profibus connector siemens
Siemens pt100 temperature transmitter
Siemens PT100 temperature sensor RTD
Thermocouple Type L
Thermocouple Type g
Siemens PT100 temperature sensor
type s thermocouple
siemens Pt100 3 wire
PT-100 temperature transducer
|
PDF
|
JUPITER m series connector
Abstract: 8810 series JUPITER connector JUPITER MS series JUPITER marking 8810 JUPITER M series connector M series FCI Jupiter
Text: JUPITER 8810 ADF Series Description Applications ț Explosion proof connectors for use in hazardous areas - screw locking system ț Explosion proof certification by B.A.S.E.E.F.A. British Approvals Service for Electrical Equipment in Flamable Atmosphere
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MaxGard MaxGard Interconnection Systems 30-400/600 Amp, 30-200A Load Breaking Maximum 600 VAC /250 VDC Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion Proof Interlocked Receptacles Benefits Russellstoll® builds a variety of benefits into one plug,
|
Original
|
0-200A
E57324,
E68085,
E123752.
LR14096.
MIL-STD-105
D2565:
PR41983;
|
PDF
|
BS2779 BSP THREAD
Abstract: IEC60079-14 EX-35-B-1-0-20-M20 M32 nylon cable gland 602 GB Series AMPHENOL dts01 galvanised conduit hazardous area ZP-C-2520-12 Radsok Amphenol Radsok
Text: Amphenol Cable Glands and Cord Grips 12-055 Amphenol Table of Contents Introduction Amphenol® Cable Glands Page Number 1 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30 8-9 EX-35 10-11 EX-40 12-13 EX-45 14-15 EE-RG 16-17
|
Original
|
EX-20
EX-25
EE-30
EX-35
EX-40
EX-45
EX-50
EX-55
EX-60
EX-65
BS2779 BSP THREAD
IEC60079-14
EX-35-B-1-0-20-M20
M32 nylon cable gland
602 GB Series AMPHENOL
dts01
galvanised conduit hazardous area
ZP-C-2520-12
Radsok
Amphenol Radsok
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Flow module For the connection of intrinsically safe flow sensors HART device with current and transistor outputs FMX-IM-2UPLi63X • ATEX category II 1 G, Ex-zone 0 ■ ATEX category II (1) D, Ex-zone 20 ■ For Ex ia resp. Ex ib sensors ■ Analog output for flow
|
Original
|
FMX-IM-2UPLi63X
30VDC
2013-07-13T20
D-45472
|
PDF
|