Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GLASS MERCURY TILT SWITCH Search Results

    GLASS MERCURY TILT SWITCH Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TBAW56 Toshiba Electronic Devices & Storage Corporation Switching Diode, 80 V, 0.215 A, SOT23 Visit Toshiba Electronic Devices & Storage Corporation
    HN1D05FE Toshiba Electronic Devices & Storage Corporation Switching Diode, 400 V, 0.1 A, ES6 Visit Toshiba Electronic Devices & Storage Corporation
    74HC4053FT Toshiba Electronic Devices & Storage Corporation CMOS Logic IC, SPDT(1:2)/Analog Multiplexer, TSSOP16B, -40 to 125 degC Visit Toshiba Electronic Devices & Storage Corporation
    5043/BEA Rochester Electronics LLC SPDT, 2 Func, 1 Channel, CMOS, CDIP16, GLASS, DIP-16 Visit Rochester Electronics LLC Buy
    MD82510/B Rochester Electronics LLC Serial I/O Controller, 1 Channel(s), CMOS, CDIP28, GLASS SEALED, DIP-28 Visit Rochester Electronics LLC Buy

    GLASS MERCURY TILT SWITCH Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    CH02-SO

    Abstract: CLIFTON PRECISION 240AC glass mercury TILT SWITCH CK30-SO SPST mechanical switch CA20-SO CH03-SO CB11-SO CB17-SO
    Text: MERCURY GLASS TILT SWITCHES Glass Mercury switches for the most part are specialty switches that allow a diversity of features often not easily obtained in our metal switches. Glass switches are used in applications that require very low tilt angles, extremely low and consistent contact resistance, and other contact configurations that are often suitable


    Original
    PDF 240AC 240AC 250DC CH02-SO CLIFTON PRECISION glass mercury TILT SWITCH CK30-SO SPST mechanical switch CA20-SO CH03-SO CB11-SO CB17-SO

    mercury SWITCH

    Abstract: PA66 GF 25 RM-RUF-45-000-BB Tilt Sensors degree 3 axis RS-RUS-00-000-BB "Vibration switch" rp-cub glass mercury TILT SWITCH RV-RUG-00-000-BB free gold detectors circuit
    Text: Table of Contents S olico is proud to announce its latest line of quality Tilt and Vibration switches. These products are a cost effective alternative to Mercury switch technology that offers a wide range of functions. Specific applications might include a safety function for a space heater, or a battery-save function for a handheld device. If you are looking for product that will sense the


    Original
    PDF RM-CUA-10-000-BB RM-RUA-10-000-BB RM-SSA-10-000-BB mercury SWITCH PA66 GF 25 RM-RUF-45-000-BB Tilt Sensors degree 3 axis RS-RUS-00-000-BB "Vibration switch" rp-cub glass mercury TILT SWITCH RV-RUG-00-000-BB free gold detectors circuit

    13001 switching

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies CONTACT FORM / STYLE Contact open 22.3 .878 Pin 0.5ø (.020) 4.7ø (.185) Horizontal Differential angle 2.92 (.114) Contact closed 10.0 (.394) These switches operate when tilted from the horizontal position.


    Original
    PDF AE043 13001 switching

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies CONTACT FORM / STYLE Contact open 8.7 .343 5.6 (.220) Horizontal Differential angle 3.6ø (.141) Contact closed Pin 0.5ø (.020) These switches operate when tilted from the horizontal position.


    Original
    PDF AE043

    TILT SWITCH

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies CONTACT FORM / STYLE 8.7 .343 Contact open 5.6 (.220) Horizontal Differential angle 3.6ø (.141) Pin 0.5ø (.020) Contact closed 5.60 (.220) Max. These switches operate when tilted from the horizontal position.


    Original
    PDF AE043 TILT SWITCH

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal Differential angle Pin 0.60ø .024 Contact closed 8.9ø (.350) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Sealed Thermostat

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal Pin 0.6ø .024 Differential angle 35.0 (1.38) Contact closed 1.8 (.071) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043 Sealed Thermostat

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal Pin 0.6ø .024 Differential angle 48.0 (1.889) Contact closed 1.8 (.071) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal Differential angle Pin 0.60ø .024 Contact closed 8.9ø (.350) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Long Electrode Horizontal Differential angle 23.0 .906 1.3 (.051) Contact closed Pin 0.5ø (.020) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Long Electrode Horizontal 12.7 .500 1.3 (.051) Differential angle Contact closed Pin 0.5ø (.020) 3.9ø (.154) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Long Electrode Horizontal 22.0 .866 1.3 (.051) Differential angle Contact closed Pin 0.5ø (.020) 4.4ø (.173) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    CW3003-0

    Abstract: glass mercury TILT SWITCH
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies CONTACT FORM / STYLE Contact open 15.2 .602 Horizontal 13.7 (.54) Differential angle 9.1ø (.366) Max. Contact closed Pin 0.2ø (.008) These switches operate when tilted from the horizontal position.


    Original
    PDF AE043 CW3003-0 CW3003-0 glass mercury TILT SWITCH

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies 38.0 1.496 16.0ø (.630) Pin 4.0ø (.157) Drawings not to scale All dimensions in mm (inches) nominal Contact open These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies 44.0 1.732 11.0ø (.443) Pin 2.4ø (.094) Drawings not to scale All dimensions in mm (inches) nominal These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal Differential angle 28.0 1.102 Contact closed 8.1ø (.319) Pin 1.0ø (.039) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal Differential angle 28.0 1.1 Contact closed 8.1ø (.32) Pin 1.0ø (.039) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    132-070

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies 23.0 .90 9.3 (.36) 177.80 (7in) Differential angle varies if pins are aligned vertically (as drawn) or horizontally Drawings not to scale All dimensions in mm (inches) nominal These switches operate when tilted from the horizontal position.


    Original
    PDF AE043 132-070

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal 22.1 .870 1.0 (.039) Differential angle Contact closed 4.9ø (.193) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    CW3004-0

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies CONTACT FORM / STYLE Contact open 15.2 .60 Horizontal 13.7 (.54) Differential angle 8.6ø (.34) Max. Contact closed Pin 0.2ø (.08) These switches operate when tilted from the horizontal position.


    Original
    PDF AE043 CW3004-0 CW3004-0

    AG3011-0

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies CONTACT FORM / STYLE 2.03 .080 13.5 (.532) Contact open Horizontal 10.03 (.395) Differential angle 8.56ø (.337) Contact closed 21.26 (.837) These switches operate when tilted from the horizontal position.


    Original
    PDF AE043 AG3011-0 AG3011-0

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies 44.0 1.73 16.0ø (.63) Pin 4.0ø (.157) Drawings not to scale All dimensions in mm (inches) nominal These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043

    glass mercury TILT SWITCH

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open 20.8 .819 Horizontal 8.1ø (.319) Differential angle Contact closed Pin 1.0ø (.039) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043 glass mercury TILT SWITCH

    Untitled

    Abstract: No abstract text available
    Text: FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies Contact open Horizontal Pin 0.5ø .020 Differential angle 5.6 (.220) Contact closed 3.6ø (.142) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle.


    Original
    PDF AE043