Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GUARDMASTER CONTROL UNIT Search Results

    GUARDMASTER CONTROL UNIT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TMPM4GQF15FG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP144-2020-0.50-002 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4GRF20FG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP176-2020-0.40-002 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4KMFWAFG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP80-1212-0.50-003 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4MMFWAFG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP80-1212-0.50-003 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4NQF10FG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP144-2020-0.50-002 Visit Toshiba Electronic Devices & Storage Corporation

    GUARDMASTER CONTROL UNIT Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Allen-Bradley en60204-1

    Abstract: allen bradley contactor B300 440R-D23021 MSR7R EN574 FUSE 451 440R D23021 440r-d23025 440R-D23022 IEC60947-5-1
    Text: Safety Relays Two Hand Relays Minotaur MSR7R & MSR7C Specifications Description The Allen-Bradley Guardmaster Minotaur MSR7R & MSR7C are logic units for monitoring and interfacing two hand control devices with a safety related circuit. The MSR7R is for use with mechanical


    Original
    PDF EN574, EN954-1, ISO13849-1, IEC/EN60204-1, IEC60947-5-1, AS4024 Allen-Bradley en60204-1 allen bradley contactor B300 440R-D23021 MSR7R EN574 FUSE 451 440R D23021 440r-d23025 440R-D23022 IEC60947-5-1

    MSR126.1T

    Abstract: MSR126T MSR126 440RN23114 440R-N23117 440R-N23120 GuardMaster MSR126R MSR126R msr126.1r 440R-N23114
    Text: Safety Relays Monitoring Safety Relays Minotaur MSR126R/T Specifications Description The Allen-Bradley Guardmaster Minotaur MSR126R/T is a safety monitoring relay that provides the very basics for safety control systems in a 22.5mm package. The MSR126R/T is designed for connection to a single channel


    Original
    PDF MSR126R/T EN954-1, ISO13849-1, EN60204-1, IEC60947-4-1, IEC60947-5-1, AS4024 EN954-1 42/115/230V 50/60Hz MSR126.1T MSR126T MSR126 440RN23114 440R-N23117 440R-N23120 GuardMaster MSR126R MSR126R msr126.1r 440R-N23114

    MSR12T

    Abstract: MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am
    Text: MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE b Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only


    Original
    PDF MSR12T S13-S14 S23-S24. MSR12T 98/37/EC) 73/23/EEC 89/336/EEC MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am

    GuardMaster

    Abstract: MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique
    Text: a Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite


    Original
    PDF 98/37/EC) 73/23/EEC 89/336/EEC GuardMaster MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique

    MSR11R

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020
    Text: a MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously


    Original
    PDF MSR11R MSR11R 98/37/EC) 73/23/EEC 89/336/EEC GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020

    GuardMaster CONTROL UNIT EN 60204-1

    Abstract: MSR16 GuardMaster safety switch GuardMaster safety switch msr16 EN1050 GuardMaster CONTROL UNIT diode led rouge 3 mm GuardMaster 1800W EN60204-1
    Text: a MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after


    Original
    PDF MSR16R/T MSR16R/T S13-S14 S23-S24. MSR16 98/37/EC) 73/23/EEC GuardMaster CONTROL UNIT EN 60204-1 GuardMaster safety switch GuardMaster safety switch msr16 EN1050 GuardMaster CONTROL UNIT diode led rouge 3 mm GuardMaster 1800W EN60204-1

    guardmaster cu2

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204
    Text: a CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor


    Original
    PDF 98/37/EC) 73/23/EEC guardmaster cu2 GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204

    GuardMaster ferrogard 21DC

    Abstract: BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster
    Text: FERROGARD GD2 b Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch


    Original
    PDF 98/37/EC 73/23/EEC GuardMaster ferrogard 21DC BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster

    guardmaster atlas 4

    Abstract: GuardMaster atlas 5 gd2 guardmaster atlas 3 safety switch guardmaster atlas safety switch cerberus cu2 ATLAS 5 gd2 guardmaster safety switch bouton poussoir ci guardmaster atlas 4 safety switch GuardMaster guardmaster cu2
    Text: ATLAS 5-GD2 a HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the


    Original
    PDF

    GuardMaster trojan 5

    Abstract: GuardMaster trojan 5 EX GuardMaster trojan 5 6 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH guardmaster trojan 5 AC15 trojan 5 bouton poussoir GuardMaster CONTROL UNIT EN 60204-1 GuardMaster wn2 4hr
    Text: TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 a Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.


    Original
    PDF

    PILZ pnoz

    Abstract: guardmaster atlas 3 safety switch Pilz safety relay Electronic security code lock system - Door Lock - Safe Lock circuit diagram guardmaster atlas 4 GuardMaster CENTURION circuit diagram of door interlock system guardmaster atlas safety switch 343-981 323-987
    Text: Issued November 1993 B16718 Machineguardinterlocking RS stock no. 325-703 323-993 351-241 351-257 323-971 323-987 325-141 325-157 325-129 325-135 324-772 333-574 759-213 343-981 350-074 319-663 319-269 319-275 319-281 Description Rotacam 2N/C contact block


    Original
    PDF B16718 PILZ pnoz guardmaster atlas 3 safety switch Pilz safety relay Electronic security code lock system - Door Lock - Safe Lock circuit diagram guardmaster atlas 4 GuardMaster CENTURION circuit diagram of door interlock system guardmaster atlas safety switch 343-981 323-987

    GuardMaster gd2

    Abstract: guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600
    Text: a CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions


    Original
    PDF 98/37/EC) 73/23/EEC GuardMaster gd2 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600

    MSR15D

    Abstract: bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA
    Text: Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät


    Original
    PDF MSR15D D13/D14ortie bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA

    MSR9T

    Abstract: A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T
    Text: ACCESSOIRES ZUBEHÖR e ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function


    Original
    PDF UL508 MSR9T A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T

    GuardMaster ferrogard 21DC

    Abstract: Ferrogard 21DC FERROCODE EN60204 Ferrogard 21AC GuardMaster FRS 6 frs3 relay ferrogard Guardmaster EN1088 frs 21 dc guardmaster
    Text: a Description (a) Description SPECIALISTS IN MACHINERY SAFETY Ferrogard FRS 1, 2, 3, 4, 5, 6, 9, 10, 20DC, 21AC, 21DC, GS1 & GS2 MAGNETICALLY OPERATED SAFETY SWITCH MAGNET-SICHERHEITSSCHALTER INTERRUPTEUR DE SECURITE MAGNETIQUES SANS CONTACT See enclosed Declaration of Conformity for details.


    Original
    PDF

    minotaur MSR6R/T Universal Safety Relay

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique
    Text: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte.


    Original
    PDF S13-S14 S23-S24. minotaur MSR6R/T Universal Safety Relay GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique

    XLP-3

    Abstract: 440C-ENET 440C-CR30-22BBB
    Text: User Manual — Original Language Guardmaster 440C-CR30 Configurable Safety Relay Catalog Number 440C-CR30-22BBB Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and


    Original
    PDF 440C-CR30 440C-CR30-22BBB RA-DU002, 440C-UM001D-EN-P 440C-UM001C-EN-P XLP-3 440C-ENET 440C-CR30-22BBB

    GuardMaster CONTROL UNIT EN 60204-1

    Abstract: minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT
    Text: MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633


    Original
    PDF 120mm, GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT

    Allen-Bradley MSR127

    Abstract: MSR126 MSR126.1T 440R-N23132 1794-PS3 Allen-Bradley 1794-PS3 GuardMaster msr127 440R-N23135 440R-N23131
    Text: Presence Sensing Safety Devices Safety Light Curtains Point of Operation Control Maximum scanning range 6m/18m 19.69ft/59.06ft Resolution (object sensitivity) 14mm/30mm (0.55in/1.18in) Maximum height of protective field 1814mm/1832mm (71.4in/72.1in) Minimum height of protective field


    Original
    PDF 6m/18m 69ft/59 14mm/30mm 55in/1 1814mm/1832mm 4in/72 314mm/332 36in/13 314mm. 1832mm Allen-Bradley MSR127 MSR126 MSR126.1T 440R-N23132 1794-PS3 Allen-Bradley 1794-PS3 GuardMaster msr127 440R-N23135 440R-N23131

    GuardMaster safety switch

    Abstract: wn2 4HR guardmaster 24VAC GuardMaster wn2 4hr minotaur msr7c EN60204-1 relay in ac application GuardMaster CONTROL UNIT
    Text: R MINOTAUR MSR7C 2 HAND CONTROL LOGIC UNIT For Capacitive Palm Button 2 hand control switch units with 2 x 1 N/O & 1N/C buttons. Power drain: Internal fuse: Safety Inputs: Indication: Relay outputs: Maximum switched current: Drop out time: Standards conformity:


    Original
    PDF 500mAT GuardMaster safety switch wn2 4HR guardmaster 24VAC GuardMaster wn2 4hr minotaur msr7c EN60204-1 relay in ac application GuardMaster CONTROL UNIT

    GuardMaster spartan

    Abstract: ATLAS 5 gd2 guardmaster allen bradley 440R-T07114 guardmaster atlas safety switch GuardMaster guardmaster atlas 3 safety switch guardmaster atlas GuardMaster atlas 5 gd2 GuardMaster 440G GuardMaster gd2
    Text: Safety Relays Timing Control Units CU1 Specifications Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 per EN 954-1 ISO13849-1 Approvals C-Tick, CE marked for all applicable directives, cULus & TÜV Power Supply


    Original
    PDF AS4024 ISO13849-1) 110/230V 440G-MT, 500mAT GuardMaster spartan ATLAS 5 gd2 guardmaster allen bradley 440R-T07114 guardmaster atlas safety switch GuardMaster guardmaster atlas 3 safety switch guardmaster atlas GuardMaster atlas 5 gd2 GuardMaster 440G GuardMaster gd2

    440R-D23171

    Abstract: guardmaster IEC 60947-5-1 440R-D23166 Allen-Bradley MSR125H MSR125H GuardMaster 440r MSR125HP allen bradley IEC 60947-5-1 440R-D23163 MSR125HP A
    Text: Safety Relays Two Hand Relays Minotaur MSR125H/HP Specifications Standards EN 574, EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 4 per EN 954-1 ISO 13849-1 Cat. IIIC per EN 574 Approvals C-Tick, CE marked for all


    Original
    PDF MSR125H/HP AS4024 MSR125H/HP MSR125H/440R-D23163 440R-D23171 guardmaster IEC 60947-5-1 440R-D23166 Allen-Bradley MSR125H MSR125H GuardMaster 440r MSR125HP allen bradley IEC 60947-5-1 440R-D23163 MSR125HP A

    MSR138DP

    Abstract: GuardMaster trojan 5 6 belden 8770 20-HIM minotaur MSR9T GuardMaster trojan 5 20D-UM006 MSR138 GuardMaster MSR9T
    Text: Safe-Off Option for PowerFlex 700S Phase II AC Drives and PowerFlex 700L Liquid-Cooled AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and


    Original
    PDF 20D-UM007D-EN-P 363068-P03 20D-UM007C-EN-P 2006Copyright MSR138DP GuardMaster trojan 5 6 belden 8770 20-HIM minotaur MSR9T GuardMaster trojan 5 20D-UM006 MSR138 GuardMaster MSR9T

    EN1088

    Abstract: ferrogard 440N-G02049 440N-G02048 allen bradley GuardMaster 440N 440N-A02057 FERROCODE EN60204 Allen-Bradley en60204-1 ferrogard gs2 GuardMaster
    Text: Interlock Switches Non contact Switches Ferrogard GS1 & GS2 Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems


    Original
    PDF EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, AS4024 EN954-1 EN1088. EN1088 ferrogard 440N-G02049 440N-G02048 allen bradley GuardMaster 440N 440N-A02057 FERROCODE EN60204 Allen-Bradley en60204-1 ferrogard gs2 GuardMaster