Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LINE REACTOR Search Results

    LINE REACTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    NFMJMPC226R0G3D Murata Manufacturing Co Ltd Data Line Filter, Visit Murata Manufacturing Co Ltd
    NFM15PC755R0G3D Murata Manufacturing Co Ltd Feed Through Capacitor, Visit Murata Manufacturing Co Ltd
    NFM15PC435R0G3D Murata Manufacturing Co Ltd Feed Through Capacitor, Visit Murata Manufacturing Co Ltd
    NFM15PC915R0G3D Murata Manufacturing Co Ltd Feed Through Capacitor, Visit Murata Manufacturing Co Ltd
    AV-THLIN2BNCM-025 Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-025 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 25ft Datasheet

    LINE REACTOR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    TPDR SERIES

    Abstract: TPDR00103R0 TPDR0153R0 TPDR0203R0 TPDR0303R0 TPDR0501R0 TPDR0601R0 TPDR0800R3 TPDR1000R2 TPDR1500R1
    Text: THREE PHASE DELTA, 600VAC, REACTORS, TPDR SERIES FEATURES AND SPECIFICATIONS SPECIFICATIONS 1.0 HIGHPOT RATING: LINE-TO-GROUND: 2500 VAC LINE-TO-LINE: 2500 VAC 2.0 MAXIMUM LEAKAGE CURRENT, EACH LINE TO GROUND, @ 600VAC, 60Hz: 10 uA max 3.0 PERFORMANCE 0.05


    Original
    PDF 600VAC, TPDR00103R0 TPDR0153R0 TPDR0601R0 TPDR0800R3 TPDR1000R2 TPDR1500R1 TPDR2000R1 TPDR SERIES TPDR00103R0 TPDR0153R0 TPDR0203R0 TPDR0303R0 TPDR0501R0 TPDR0601R0 TPDR0800R3 TPDR1000R2 TPDR1500R1

    inductance 0.2mh

    Abstract: TPDR00103R0 TPDR0153R0 TPDR0203R0 TPDR0303R0 TPDR0501R0 TPDR0601R0 TPDR0800R3 TPDR1000R2 TPDR1500R2
    Text: THREE PHASE DELTA, 600VAC, REACTORS, TPDR SERIES FEATURES AND SPECIFICATIONS SPECIFICATIONS 1.0 HIGHPOT RATING: LINE-TO-GROUND: 2500 VAC LINE -TO-LINE: 2500 VDC 2.0 MAXIMUM LEAKAGE CURRENT, EACH LINE TO GROUND, @ 600VAC, 60Hz: 10 uA max 3.0 PERFORMANCE 0.05


    Original
    PDF 600VAC, TPDR00103R0 TPDR0153R0 TPDR0601R0 TPDR0800R3 TPDR1000R2 TPDR1500R2 TPDR2000R2 inductance 0.2mh TPDR00103R0 TPDR0153R0 TPDR0203R0 TPDR0303R0 TPDR0501R0 TPDR0601R0 TPDR0800R3 TPDR1000R2 TPDR1500R2

    mte overload

    Abstract: No abstract text available
    Text: Enhanced Design Reactors for Line and Load The MTE RLW REACTOR is MTE’s newest reactor line that, like our RL Reactor product line, keeps equipment running longer by absorbing many of the power line disturbances which otherwise damage or shut down inverters, variable frequency drives VFDs , variable speed controllers, and other sensitive


    Original
    PDF UL-508, UL508A W13330 1-800-455-4MTE RLW-2page-09 mte overload

    passive harmonic filters

    Abstract: high voltage reactor fn 310 noise filter MTBF
    Text: Line filters and reactors FN 3400 Three-phase line filter • ■ ■ ■ EMC filter for applications with high noise levels Integrated line reactor for low frequency interference and harmonics reduction Compact all-in-one solution for motor drives Significant increase of conducted


    Original
    PDF C/400V Mil-HB-217F) 480/277VAC 2768-m 22768-m passive harmonic filters high voltage reactor fn 310 noise filter MTBF

    18l0015wh

    Abstract: 18L0012WH 9L11XPB015S Heavy Duty Distribution Arresters 9L20 18L0065WH relay 04501 9L15ECC001 0-650 VAC 3 Pole 18L0009WH 54L514 GED-7060A
    Text: Capacitors, Arresters and Harmonic Filters Line/Load Reactors—up to Line/Load Reactors—Three-phase Reactors .20-4 Matrix Series D Harmonic Filters .20-6


    Original
    PDF

    Allen-bradley 1557

    Abstract: NH5 Diode 1321-M001 1321-RWR 1321-3R E180243 Allen-bradley 1557 drive 1321-3R130-B 1321-3RB250-B E112313
    Text: 1321 Power Conditioning Products Technical Data LINE REACTORS REFLECTED WAVE DEVICES ISOLATION TRANSFORMERS COMMON MODE CHOKES DC LINK CHOKES DON’T IGNORE THE COST OF POWER LINE DISTURBANCE 1321 Power Conditioning Products Overview Allen-Bradley reactors help keep equipment running longer by absorbing many of the power line disturbances which can


    Original
    PDF 1321-3R 1321-TD001N-EN-P 1321-TD001M-EN-P Allen-bradley 1557 NH5 Diode 1321-M001 1321-RWR E180243 Allen-bradley 1557 drive 1321-3R130-B 1321-3RB250-B E112313

    PXE100255

    Abstract: KPC102255 HSZ070245 integrated ballast capacitor 100 uF ELECTRONIC dimming BALLAST
    Text: Product Specification Bulletin Double Ended Compact 70W 50 Hz Reactor Ballast HSZ070245 IEC 60922: 1997 Input Volts 240 HSZ: Line Current Amps 0.39 Operating Open Circuit Starting 0.75 0.78 Regulation ±6% Line Volts Lamp Watts ±10% Temperature Ratings


    Original
    PDF HSZ070245 PXE100255 KPC102255 08-Dec-00 YC95-1 PXE100255 KPC102255 HSZ070245 integrated ballast capacitor 100 uF ELECTRONIC dimming BALLAST

    Untitled

    Abstract: No abstract text available
    Text: Three-phase Line Reactor for Motor Drive Applications Line Reactors RWK 212 Provision of 4% impedance Reduction of mains harmonics Approvals Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents Improvement of true power factor


    Original
    PDF UL508C

    21235

    Abstract: 680A
    Text: Line reactors RWK 212 Three-phase line reactor for motor drive applications • ■ ■ ■ ■ ■ Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents


    Original
    PDF C/400V Mil-HB-217F) 500/288VAC 21235 680A

    Untitled

    Abstract: No abstract text available
    Text: Line Reactors RWK 212 Three-phase Line Reactor for Motor Drive Applications • ■ ■ ■ ■ ■ Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents


    Original
    PDF UL508C C/400V Mil-HB-217F)

    212-21-KL

    Abstract: DRUCK 910
    Text: Line Reactors RWK 212 Three-phase Line Reactor for Motor Drive Applications • ■ ■ ■ ■ ■ Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents


    Original
    PDF UL508C C/400V Mil-HB-217F) 212-21-KL DRUCK 910

    LINE REACTOR

    Abstract: KS245 212-95 reactor rwk212
    Text: Line filters and reactors RWK 212 Three-phase line reactor for motor drive applications n n n n n n Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents


    Original
    PDF C/400V Mil-HB-217F) 500/288VAC 2768-m 22768-m LINE REACTOR KS245 212-95 reactor rwk212

    Untitled

    Abstract: No abstract text available
    Text: Line filters and reactors RWK 212 Three-phase line reactor for motor drive applications • ■ ■ ■ ■ ■ Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents


    Original
    PDF C/400V Mil-HB-217F) 500/288VAC 400VAC, Se255 2768-m 22768-m

    centrifuge

    Abstract: bonitron elevator schematic vfd schematics monitor schematic sports day ac drive schematic single phase ac vfd
    Text: M3345 Line Regen Modules Overvoltage Solutions for AC Drives TYPE-1 M3345 Line Regen Modules are used with AC Drives to eliminate overvoltage faults. Bonitron’s M3345 Line Regen is used in systems with extended braking times or frequent regeneration, and makes any


    Original
    PDF M3345 M3345 TYPE-13 M3452 centrifuge bonitron elevator schematic vfd schematics monitor schematic sports day ac drive schematic single phase ac vfd

    Untitled

    Abstract: No abstract text available
    Text: Line Reactors RWK 212 Three-phase Line Reactor for Motor Drive Applications Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Approvals UL508C up to 400A. For use with AC or DC drives (power conversion equipment only


    Original
    PDF UL508C UL508C,

    Untitled

    Abstract: No abstract text available
    Text: Seite 1 LR3 40-4/50 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20,


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Seite 1 LR3 40-4/10 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20,


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Seite 1 LR3 40-4/16 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20,


    Original
    PDF

    RL-01802

    Abstract: RL-00201 RL40003
    Text: 3-Phase Reactors Line/Load Reactors • • • • • • • • • • Increase Drive System Reliability Filter Power Line Disturbances Reduce Harmonics Reduce Surge Currents Reduce dv/dt Extend Transistor Life Reduce Motor Noise and Temperature Reduce Voltage Doubling Effects


    Original
    PDF N9525 1-800-455-4MTE 1141C RL-01802 RL-00201 RL40003

    Untitled

    Abstract: No abstract text available
    Text: Line Reactors RWK 212 Three-phase Line Reactor for Motor Drive Applications Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Approvals UL508C up to 400A. For use with AC or DC drives (power conversion equipment only


    Original
    PDF UL508C UL508C,

    reactor

    Abstract: No abstract text available
    Text: Seite 1 LR3 40-4/35 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20,


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Seite 1 LR3 40-4/25 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20,


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Seite 1 LR3 40-4/125 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20,


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Seite 1 LR3 40-4/2 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20,


    Original
    PDF