Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MAGNETIC DOOR SENSOR Search Results

    MAGNETIC DOOR SENSOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MRMS591P Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRMS581P Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRUS74SD-001 Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRMS791B Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRUS74SK-001 Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd

    MAGNETIC DOOR SENSOR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    ZO 607 TRIAC

    Abstract: RTCA DO-160 iso 7137 TRIAC zo 607 MA NAS 1149 MS3320 EN3155 Cross Reference Full Line Condensed Catalogue 1977 DIN 72585 a1 4.1 RBS 6302 NAS1149
    Text: Contents Introduction Thermal Overcurrent Circuit Breakers Thermal-Magnetic Overcurrent Circuit Breakers Hydraulic-Magnetic and Magnetic Overcurrent Circuit Breakers High Performance Circuit Breakers and Battery Switches Door Locking, Time Delay and Motor Protection Controls


    Original
    PDF

    GLS-S1

    Abstract: GLS-M1 OMron GLS-m1 proximity sensor by omron GLS-1 MAGNETIC PROXIMITY SENSOR omron proximity sensor omron gls OMron GLS-1
    Text: R Magnetic Proximity Sensor GLS Easy-to-Use Magnetic Proximity Sensor H Compact reed-switch size saves space on machines H Ideal for door and cover closures in applications without operator hazards H Separate sensor and magnet parts allow multiple magnet positions for a


    Original
    PDF 1-800-55-OMRON GLS-S1 GLS-M1 OMron GLS-m1 proximity sensor by omron GLS-1 MAGNETIC PROXIMITY SENSOR omron proximity sensor omron gls OMron GLS-1

    Untitled

    Abstract: No abstract text available
    Text: R Magnetic Proximity Sensor GLS Easy-to-Use Magnetic Proximity Sensor H Compact reed-switch size saves space on machines H Ideal for door and cover closures in applications without operator hazards H Separate sensor and magnet parts allow multiple magnet positions for a


    Original
    PDF 1-800-55-OMRON

    F39-TGR-NT

    Abstract: F39-TGR-CVL-B-10-R OMRON G9SA-321-T075 F39-TGR-SB4-CVLB F3S-TGR-NMPR-20-02 F39-TGR-CVL-N-10 F3S-TGR-NMPR-21-02 F39-TGR-CVL-B-5-R F3S-TGR-NLPR-20-10 F3S-TGR-NSMR-20-05
    Text: Compact Magnetic Non-contact Safety Switches F3S-TGR-N@R Magnetic Non-contact switches are designed to interlock hinge, sliding or removal guard doors. • Contact-free detection of the closing/ opening of a door • Non-contact = no abrasion = no particles


    Original
    PDF EN60947-5-3 E18E-EN-02 F39-TGR-NT F39-TGR-CVL-B-10-R OMRON G9SA-321-T075 F39-TGR-SB4-CVLB F3S-TGR-NMPR-20-02 F39-TGR-CVL-N-10 F3S-TGR-NMPR-21-02 F39-TGR-CVL-B-5-R F3S-TGR-NLPR-20-10 F3S-TGR-NSMR-20-05

    F39-TGR-CVL-B-10-R

    Abstract: F39-TGR-SB4-CVLB F3S-TGR-NSMR-21-05 F3S-TGR-NMPR-21-02 OMRON G9SA-321-T075 F3S-TGR-NMPR-20-02 F39-TGR-NT F39-TGR-CVL-B-2-R NE1A-SCPU01L F3S-TGR-NLPR-21-05
    Text: Compact Magnetic Non-contact Safety Switches F3S-TGR-N@R Magnetic Non-contact switches are designed to interlock hinge, sliding or removal guard doors. • Contact-free detection of the closing/ opening of a door • Non-contact = no abrasion = no particles


    Original
    PDF EN60947-5-3 E18E-EN-02 F39-TGR-CVL-B-10-R F39-TGR-SB4-CVLB F3S-TGR-NSMR-21-05 F3S-TGR-NMPR-21-02 OMRON G9SA-321-T075 F3S-TGR-NMPR-20-02 F39-TGR-NT F39-TGR-CVL-B-2-R NE1A-SCPU01L F3S-TGR-NLPR-21-05

    schematic diagram ac drive and plc

    Abstract: circuit diagram of energy saving lamp 230v aC PLC Current Rating of IN4004 diode arcolectric switches BUZZER WATERPROOF IN4004 metal proximity switch schematic schematic proximity switch transformer AC ENERGY SAVING CIRCUIT DIAGRAM of 25 watt
    Text: ARCOLECTRIC SERIES 4500 MAGNETIC SWITCH For Door Operation with POWERBUS SOLID STATE MAGNETIC AC LAMP SWITCH The 4500 module is a solid state, sub-miniature, magnetically operated unit which utilises Hall Effect technology to directly switch up to 75 watt AC resistive lamp loads. It is also


    Original
    PDF 230Vac 110Vac 4500/4600/4700BUS schematic diagram ac drive and plc circuit diagram of energy saving lamp 230v aC PLC Current Rating of IN4004 diode arcolectric switches BUZZER WATERPROOF IN4004 metal proximity switch schematic schematic proximity switch transformer AC ENERGY SAVING CIRCUIT DIAGRAM of 25 watt

    MP1014

    Abstract: MP101401 IEC529 MP101403 UL1569 24
    Text: MAGNETIC SENSOR MP1014 Series Digital Hall-effect proximity sensor in low-profile flange-mount housing. Features Applications  Capable of millions of operations  Door position sensing  Meets IEC529 IPX5 for water protection  Flow sensing  Reverse Battery Protection to -24VDC


    Original
    PDF MP1014 IEC529 -24VDC MP101402 MP101403 MP101401 MP101402 MP101403 UL1569, MP101401 UL1569 24

    Untitled

    Abstract: No abstract text available
    Text: MAGNETIC SENSOR MP1013 Series Hall-effect position sensor with convenient snap-fit mounting. Features Applications „ Solid state reliability „ Speed sensing „ Excellent output stability over operating temperature range „ Door interlock sensing „ Open Collector NPN output can be used with bipolar switch or


    Original
    PDF MP1013 MP101301

    Untitled

    Abstract: No abstract text available
    Text: MAGNETIC SENSOR MP1014 Series Digital Hall-effect position sensor in low-profile fl ange-mount housing. Features Applications „ Capable of millions of operations „ Door position sensing „ Reverse Battery Protection to -24 V DC „ Flow sensing „ MP101401 south pole activated unipolar switching


    Original
    PDF MP1014 MP101401 MP101401 UL1569,

    vde 0660-209 en 1088 en 954-1 ip 67

    Abstract: VDE-0660-209 VDE 0660-209 D40B-2 D40B-2D3 D40B d40b1 D40B-J1 vde 0660-209 en 1088 D40B-1B10
    Text: Compact Non-contact Door Switch D40B Series CSM_D40B_DS_E_3_1 Detects the open/closed state of doors without making contact and has high resistance to the environment. • Detects the open/closed state of doors without making contact by combining a special magnetic Actuator and


    Original
    PDF

    CM-S621

    Abstract: CM-S621PC10
    Text: Safety Interlock Switches CM Series Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers • Combine door switch monitoring and E-stop monitoring by using the CM-S41 controller • Monitor is single switch to CAT4 with the CM-S30 controller


    Original
    PDF CM-S41 CM-S30 CM-S30 CM-S21 C42I-E-01 CM-S621 CM-S621PC10

    301AN

    Abstract: DC-13 FR 422
    Text: Pag Print - Create PDF - 28.09.2011 - 11:14:03h Create EXCEL file Datasheet - SRB 301AN Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers Series PROTECT SRB / SRB 301AN Preferred typ • Fit for signal evaluation of outputs of safety magnetic


    Original
    PDF 301AN categor01 srb301an ksrb3l20 srbp06 301AN DC-13 FR 422

    magnetic reed switch

    Abstract: "Reed Switch" magnetic contact Magnetic latching reed switch MAGNETIC SWITCH door closed sensors close door door switch magnetic head 2mm electronic door latch
    Text: Door Operation Sensors Switch built-in magnet door latch PCSW series Issue date: February 2007 • All specifications are subject to change without notice. • Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific


    Original
    PDF 2002/95/EC, magnetic reed switch "Reed Switch" magnetic contact Magnetic latching reed switch MAGNETIC SWITCH door closed sensors close door door switch magnetic head 2mm electronic door latch

    door closed sensors

    Abstract: magnetic heads 1mm
    Text: 1/2 Door Operation Sensors Switch Built-in Magnet Door Latch PCSW Series TDK SW Catch (Sensing Door Latch) holds the doors, panels, and lids on all types of equipment. This latch also contains a reed switch which can be used to sense if a door is open or closed. The


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: The MSS Series MODEL MSS–19C 3/4” Concealed Security Sensor Security Contacts are made with a decades-old technology called the Reed switch. Reed switches have three inherent weaknesses when used in security contacts. They are 1 Easily defeated with magnets,


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: MAGNASPHERE has Created the L2 Series HSS “High Security Sensor” – The Next Generation Sensors That Meet UL 634 Level 2 High Security Standards for SCIFs, Safes and Vaults and All Other High Level Secure Applications. ULI HIGH SECURITY LEVEL 2 CUL HIGH SECURITY


    Original
    PDF

    elevator door sensor

    Abstract: elevator Door door closed sensors metal detection magnetic door sensor diagram of reed switch Metal detection sensor distance Metal detection sensor
    Text: Sensing the Closure Closure of Fire, Safety, and Emergency Doors Using MEDER’s Unique Ferromagnetic Metal Detection Sensors REED RELAYS REED SENSORS REED SWITCHES Introduction Figure 1. Screw mount version diagram of MK02 Series metal detection reed sensors


    Original
    PDF MK02/6MK02/6-0 MK02/6MK02/6-1 MK02/7MK02/7-0 MK02/7MK02/7-1 elevator door sensor elevator Door door closed sensors metal detection magnetic door sensor diagram of reed switch Metal detection sensor distance Metal detection sensor

    Is310 intellisense dip switch

    Abstract: 7939WG Honeywell 11WH pir motion sensor 947-75TWH DT435T intellisense is310 CASH BOX GUARD EMPS-70W 947WH
    Text: HONEYWELL SECURITY & CUSTOM ELECTRONICS Sensors Honeywell provides a sensor line that’s unsurpassed for quality, design and performance. Our field-proven, installation-friendly products, including PIRs, magnetic contacts, DUAL TECs and FlexGuard®, the world's


    Original
    PDF 955WH 914WH 913WH 913BR 367WH 367BR Is310 intellisense dip switch 7939WG Honeywell 11WH pir motion sensor 947-75TWH DT435T intellisense is310 CASH BOX GUARD EMPS-70W 947WH

    BLENDER SPEED CONTROL

    Abstract: circuit diagram of washing machine door lock system ACS712 AN295046 137 hall SENSOR water level indicator using microcontroller acs712 Applications vane air flow sensor 4 pin linear hall sensor inductive water level sensor for washing machine
    Text: Integrating Hall-Effect Magnetic Sensor Technology into Modern Household Appliances by: Monica Thomas, Michael Doogue Allegro MicroSystems, Inc., Worcester, MA. USA With the extensive variety of solutions available for position, speed, and current sensing applications, designers can select optimal technologies and packages to


    Original
    PDF AN295046 BLENDER SPEED CONTROL circuit diagram of washing machine door lock system ACS712 AN295046 137 hall SENSOR water level indicator using microcontroller acs712 Applications vane air flow sensor 4 pin linear hall sensor inductive water level sensor for washing machine

    405FW

    Abstract: RDS80004 proximity detectors axle ZS-00228-050 ZS-00341 ZS-00341-02 "Proximity Sensors" train eddy Proximity Sensor sensor magnetic vehicle presence honeywell 922
    Text: Proximity Sensors Line Guide Uncommon sense. Honeywell Sensing and Control S&C offers environmentally sealed proximity sensors in a variety of technologies — including Eddy Current Killed Oscillator (ECKO) and Hall-effect. Once a metallic object is detected in front of


    Original
    PDF 003703-1-EN 405FW RDS80004 proximity detectors axle ZS-00228-050 ZS-00341 ZS-00341-02 "Proximity Sensors" train eddy Proximity Sensor sensor magnetic vehicle presence honeywell 922

    Untitled

    Abstract: No abstract text available
    Text: Wireless Door/Window Sensor E3T-MDCCP 315 MHz E8T-MDCCP (868 MHz) E9T-MDCCP (902 MHz) Features The ILLUMRA Wireless Door/Window Sensor maximizes the energy savings of heating and air conditioning systems by providing wireless status of windows and/ or doors. The sensor uses a magnet contact


    Original
    PDF E3R-R02-5IBBP AHD0355B

    HAL824

    Abstract: HAL1820 CNC MACHINE ELECTRICAL DIAGRAM HAL825 HAL549 hal203 HAL1822 HAl3625 hal576 HAL102
    Text: HALL EFFECT SENSORS HOW TO USE THIS GUIDE: MARKET Automotive STEP Find your 1 application and identify Configuration Code APPLICATION Open-close sensor Seatbelt lock sensor Reverse position sensor Door ajar sensor Solid-state switch Seat position Sunroof Fan speed


    Original
    PDF HAL2810 HAL2830 HAL2850 HAL3625 HAL824 HAL1820 CNC MACHINE ELECTRICAL DIAGRAM HAL825 HAL549 hal203 HAL1822 HAl3625 hal576 HAL102

    door closed sensors

    Abstract: PCSW303B3B000 PCSW303B catalog reed switch PCSW303B1B000
    Text: Sensors SW CATCHES SENSING DOOR LATCHES TDK SW Catch (Sensing Door Latch) holds the doors, panels, and lids on all types of equipment. This latch also contains a reed switch which can be used to sense if a door is open or closed. The switch is activated by a unique TDK-designed magnetic circuit.


    OCR Scan
    PDF

    PCSW303B3B000

    Abstract: OA81
    Text: 13 Switches Sensors Com plex function SW CATCHES Magnet door latches with built-in reed switch PCSW series TDK SW Catch Sensing Door Latch holds the doors, panels, and lids on all types of equipment. This latch also contains a reed switch which can be used to sense if a door is open or closed. The


    OCR Scan
    PDF AVE-002 PCSW303B3B000 OA81