mini DIN 3
Abstract: mini din dc connector 7000_en_00
Text: MINI MCR-SL-I-I -SP MINI MCR-SL-U-U(-SP) Standard Signal 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The standard signal 3-way isolating amplifier MINI MCR-SL-I-I(-SP) / MINI MCR-SL-U-U(-SP) is used to electrically isolate, condition, amplify, and
|
Original
|
PDF
|
com/general/7000
mini DIN 3
mini din dc connector
7000_en_00
|
phoenix contact MCR R I 4v
Abstract: MCR-C-UI-UI current transmitter 4.20 mA MCR-C-UI-UI-450-DCI
Text: MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description • configurable inputs and outputs • signal conversion/amplification • 3-way-isolation • zero/span adjustment • 17.5 mm ME housing The MCR 3-way modules are used for electrical
|
Original
|
PDF
|
100mV
phoenix contact MCR R I 4v
MCR-C-UI-UI
current transmitter 4.20 mA
MCR-C-UI-UI-450-DCI
|
phoenix contact MCR R I 4v
Abstract: MCR-C-UI-UI-450-DCI MCR-C-UI-UI
Text: MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description • configurable inputs and outputs • signal conversion/amplification • 3-way-isolation • zero/span adjustment • 17.5 mm ME housing The MCR 3-way modules are used for electrical
|
Original
|
PDF
|
100mV
phoenix contact MCR R I 4v
MCR-C-UI-UI-450-DCI
MCR-C-UI-UI
|
H521
Abstract: EX 931
Text: Extract from the online catalog MINI MCR-SL-I-U-4 Order No.: 2813538 Illustration shows the product MINI MCR-SL-U-I-O MCR 3-way isolating amplifier, for electrical isolation of analog signals,
|
Original
|
PDF
|
IF-2009)
MINI-SYSPS-100-240AC/24DC/1
H521
EX 931
|
H521
Abstract: No abstract text available
Text: Extract from the online catalog MINI MCR-SL-I-U-4 Order No.: 2813538 Illustration shows the product MINI MCR-SL-U-I-O MCR 3-way isolating amplifier, for electrical isolation of analog signals,
|
Original
|
PDF
|
IF-2009)
H521
|
mini class t amplifier
Abstract: 2813541
Text: MINI MCR-SL-I-U-0 -SP MINI MCR-SL-I-U-4(-SP) Standard Signal 3-Way Isolating Amplifier INTERFACE Data Sheet PHOENIX CONTACT - 06/2006 Description The MINI MCR-SL-I-U-.(-SP) standard signal 3-way isolating amplifier is used to electrically isolate, condition,
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog MINI MCR-SL-I-U-0 Order No.: 2813541 Illustration shows the product MINI MCR-SL-U-I-O MCR 3-way isolating amplifier, for electrical isolation of analog signals,
|
Original
|
PDF
|
IF-2009)
MINI-PS-100-240AC/24DC/1
MINI-SYSPS-100-240AC/24DC/1
|
MCR-C-UI-UI-450-DCI
Abstract: phoenix contact "MCR R I 4v" mcr-c-ui phoenix contact MCR R I 4v
Text: MCR-C-UI-UI -450 -DCI(-NC) 3-way isolation amplifier INTERFACE Data Sheet 100238_en_02 PHOENIX CONTACT - 01/2008 Description Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals. The
|
Original
|
PDF
|
|
MCR-C-UI-UI
Abstract: phoenix isolator 100mV7
Text: MCR-C-UI-UI- 450 -DCI(-NC) Configurable 3-Way Isolation Amplifier 1. Short Description • Configurable inputs and outputs • Signal conversion/amplification • 3-way isolation • Zero/span adjustment • 17.5 mm ME housing Isolation MCR 3-way isolation amplifiers are used to electrically
|
Original
|
PDF
|
100mV
MCR-C-UI-UI
phoenix isolator
100mV7
|
MCR-C-UI-UI
Abstract: phoenix isolator 2810913 phoenix contact MCR R I 4v MCR-C-UI-UI-450-DCI MCR-C-UI/UI-450-DCI in26 phoenix contact "MCR R I 4v" mcr-c-ui 2810939 mcr-c-ui-ui-dci-nc phoenix contact MCR
Text: MCR-C-UI-UI -450 -DCI(-NC) 3-way isolation amplifier INTERFACE Data Sheet 100238_en_02 PHOENIX CONTACT - 01/2008 Description Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals. The
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: MINI MCR-SL-UI-UI -SP (-NC) Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog signals.
|
Original
|
PDF
|
com/general/7000
|
IN34 diode
Abstract: MCR-C-UI-UI MCR-C-UI/UI-DCI calibration certificate equivalent diode for diode IN34 in26 in34 datasheet 2810913 854370
Text: Extract from the online catalog MCR-C-UI-UI-DCI Order No.: 2810913 MCR 3-way isolating amplifier, with configurable I/O, for the electrical isolation of analog signals, with GL approval, preconfigured. For
|
Original
|
PDF
|
IF-2009)
IN34 diode
MCR-C-UI-UI
MCR-C-UI/UI-DCI
calibration certificate
equivalent diode for diode IN34
in26
in34 datasheet
2810913
854370
|
Untitled
Abstract: No abstract text available
Text: MINI MCR-SL-U-UI -SP (-NC) Configurable 3-Way Isolating Amplifier INTERFACE Data Sheet PHOENIX CONTACT - 07/2005 Description The configurable 3-way isolating amplifier MINI MCR-SL-U-UI(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog signals.
|
Original
|
PDF
|
|
Hz-30Hz
Abstract: 305341
Text: Extract from the online catalog MINI MCR-SL-SHUNT-UI-NC Order No.: 2810780 MCR 3-way isolating amplifier, with configurable input/output, for electrical isolation and conversion of analog signals in the mV range,
|
Original
|
PDF
|
IF-2009)
Hz-30Hz
305341
|
|
MCR-C-UI-UI
Abstract: No abstract text available
Text: Extract from the online catalog MCR-C-UI-UI-DCI Order No.: 2810913 MCR 3-way isolating amplifier, with configurable I/O, for the electrical isolation of analog signals, with GL approval, preconfigured. For
|
Original
|
PDF
|
IF-2009)
MCR-C-UI-UI
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog MINI MCR-SL-I-I Order No.: 2864406 MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0 4 mA . 20 mA, output signal:
|
Original
|
PDF
|
IF-2009)
|
MCR-C-UI-UI
Abstract: No abstract text available
Text: Phoenix Contact Electronic Catalog 12.01.2001 MCR-C-UI-UI-DCI with configurable input and output AVF M3 8 rigid IEC 2 [mm ] Connection data solid 0.2-2.5 flexible stranded AWG 0.2-2.5 24-14 Description Type MCR 3-way isolater, for analog signal isolation
|
Original
|
PDF
|
89/336/EEC
MCR-C-UI-UI
|
IN53
Abstract: IN41 IN59
Text: MINI MCR-SL-SHUNT-UI -SP (-NC) Configurable 3-way isolating amplifier INTERFACE Data sheet 103511_en_01 1 PHOENIX CONTACT - 01/2009 Description The MINI MCR-SL-SHUNT-UI(-SP)(-NC) 6.2 mm slim configurable 3-way isolating amplifier converts mV voltages into standard signals.
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog MINI MCR-SL-UI-UI-SP-NC Order No.: 2864163 The illustration shows the versions with screw connection MCR 3-way isolating amplifier, I/O can be configured via DIP
|
Original
|
PDF
|
IF-2009)
|
wiring diagram of ups
Abstract: mini ups system circuit design mini ups system TBUS-2
Text: Extract from the online catalog MINI MCR-SL-U-UI-SP-NC Order No.: 2810078 MCR 3-way isolation amplifier, with configurable input/output, for electrical isolation and conversion of analog signals up to 30 V, with
|
Original
|
PDF
|
IF-2009)
wiring diagram of ups
mini ups system circuit design
mini ups system
TBUS-2
|
mini ups system circuit design
Abstract: mini ups system wiring diagram of ups phoenix contact 2865007 mini din dc connector Phoenix ups UPS ONLINE CIRCUIT DIAGRAM
Text: Extract from the online catalog MINI MCR-SL-U-UI-NC Order No.: 2865007 MCR 3-way isolation amplifier, with configurable input/output, for electrical isolation and conversion of analog signals up to 30 V, with
|
Original
|
PDF
|
IF-2009)
mini ups system circuit design
mini ups system
wiring diagram of ups
phoenix contact 2865007
mini din dc connector
Phoenix ups
UPS ONLINE CIRCUIT DIAGRAM
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog MINI MCR-SL-UI-UI-NC Order No.: 2864150 MCR 3-way isolating amplifier for electrical isolation of analog signals, input/output configurable via DIP switch, with screw connection, not
|
Original
|
PDF
|
IF-2007)
|
mini ups system circuit design
Abstract: No abstract text available
Text: Extract from the online catalog MINI MCR-SL-U-UI-SP-NC Order No.: 2810078 MCR 3-way isolation amplifier, with configurable input/output, for electrical isolation and conversion of analog signals up to 30 V, with
|
Original
|
PDF
|
IF-2009)
mini ups system circuit design
|
PT100 2 wire temperature sensor
Abstract: PT-100 pt100 temperature sensor circuit connection MCR-SL-PT-100-SP pt100 on linearity PT100 temperature sensor class B PT100 resistor MCR-SL-PT100-SP PT100 IEC 751
Text: MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor IEC 751/ EN 60 751 into binary alarm switching signals. The sensor is supplied from the module with a low current. The resultant voltage drop is amplified in the
|
Original
|
PDF
|
MCR-SL-PT100-SP
PT-100
MCR-SL-PT-100-SP
PT-100
PT100
PT100 2 wire temperature sensor
pt100 temperature sensor circuit connection
pt100 on linearity
PT100 temperature sensor class B
PT100 resistor
PT100 IEC 751
|