Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NAMUR ISOLATING SWITCHING AMPLIFIER Search Results

    NAMUR ISOLATING SWITCHING AMPLIFIER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DCL541A01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable Visit Toshiba Electronic Devices & Storage Corporation
    DCL542H01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: High / Output enable Visit Toshiba Electronic Devices & Storage Corporation
    DCL541B01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable Visit Toshiba Electronic Devices & Storage Corporation
    DCL542L01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: Low / Output enable Visit Toshiba Electronic Devices & Storage Corporation
    DCL540H01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High / Output enable Visit Toshiba Electronic Devices & Storage Corporation

    NAMUR ISOLATING SWITCHING AMPLIFIER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IMC-Di-22Ex-PNO/24VDC The 2-channel isolating switching amplifier IMC-Di-22Ex-PNO/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR , variable resistances or potential-free


    Original
    IMC-Di-22Ex-PNO/24VDC IMC-Di-22Ex-PNO/24VDC 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IMC-DI-22EX-PNC/24VDC The 2-channel isolating switching amplifier IMC-DI-22EX-PNC/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR , variable resistances or potential-free


    Original
    IMC-DI-22EX-PNC/24VDC IMC-DI-22EX-PNC/24VDC 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-12EX-MT The single-channel isolating switching amplifier IM1-12EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-12EX-MT IM1-12EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-121EX-T The single-channel isolating switching amplifier IM1-121EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-121EX-T IM1-121EX-T D-45472 2013-07-13T20 PDF

    Im1-12EX

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-12EX-R The single-channel isolating switching amplifier IM1-12EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-12EX-R IM1-12EX-R D-45472 2013-07-13T20 Im1-12EX PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM12-22EX-R The dual-channel isolating switching amplifier IM12-22EX-R is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM12-22EX-R IM12-22EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-MT The dual channel isolating switching amplifier IM1-22EX-MT is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-MT IM1-22EX-MT D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-231EX-R The dual channel isolating switching amplifier IM1-231EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-231EX-R IM1-231EX-R D-45472 2013-07-13T20 PDF

    Im1-12ex-t

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-12EX-T The 1-channel isolating switching amplifier IM1-12EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-12EX-T IM1-12EX-T D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-R The dual-channel isolating switching amplifier IM1-22EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-R IM1-22EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451EX-R The 4-channel isolating switching amplifier IM1-451EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-451EX-R IM1-451EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-T The dual-channel isolating switching amplifier IM1-22EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-T IM1-22EX-T D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-121EX-R The single-channel isolating switching amplifier IM1-121EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-121EX-R IM1-121EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451EX-T The 4-channel isolating switching amplifier IM1-451EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-451EX-T IM1-451EX-T D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IMB-DI-451Ex-P/24VDC The four-channel isolating switching amplifier IMB-DI-451Ex-P/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential


    Original
    IMB-DI-451Ex-P/24VDC IMB-DI-451Ex-P/24VDC 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM12-22EX-R/24VDC The dual-channel isolating switching amplifier IM12-22EX-R/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM12-22EX-R/24VDC IM12-22EX-R/24VDC D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IME-DI-22Ex-R/24VDC The dual-channel isolating switching amplifier IME-DI-22EX-R/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR or potential-free contactors can be connected to the


    Original
    IME-DI-22Ex-R/24VDC IME-DI-22EX-R/24VDC D-45472 2013-07-13T20 PDF

    IM1-22EX-R/24VDC

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-R/24VDC The dual-channel isolating switching amplifier IM1-22EX-R/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-R/24VDC IM1-22EX-R/24VDC D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IME-DI-22EX-T/24VDC The dual-channel isolating switching amplifier IME-DI-22EX-T/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR or potential-free contactors can be connected to the device.


    Original
    IME-DI-22EX-T/24VDC IME-DI-22EX-T/24VDC D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451-R Sensors according to EN 60947-5-6 NAMUR or potential-free contactors can be connected to the 4-channel isolating transducer IM1-451R. When using mechanical contacts, the wirebreak and short-circuit monitoring must be


    Original
    IM1-451-R IM1-451R. 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451-T Sensors according to EN 60947-5-6 NAMUR or potential-free contactors can be connected to the 4-channel isolating transducer IM1-451T. When using mechanical contacts, the wirebreak and short-circuit monitoring must be


    Original
    IM1-451-T IM1-451T. D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-R/K51 Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors. Three front panel switches are available to set the output mode separately for each channel (NO or NC mode), as well as to enable/disable wire-break (WB) and short-circuit (SC)


    Original
    IM1-22EX-R/K51 D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IMB-DI-44Ex-P/24VDC The four-channel isolating switching amplifier IMB-DI-44EX-P/24VDC is equipped with intrinsically safe input circuits. The green LED indicates operational readiness. The yellow LED indicates the switching


    Original
    IMB-DI-44Ex-P/24VDC IMB-DI-44EX-P/24VDC 2013-07-13T20 D-45472 PDF

    Namur isolating switching amplifier

    Abstract: namur output DIN19234 IM12-02B-N-ZW0 IM12-04N-N-ZW0
    Text: IM 12 NAMUR Inductive Proximity Sensors DC Highlights • Shielded or unshielded • Enclosure rating IP 67 • NAMUR to DIN 19 234 • LED status indicator • High switching frequency • Robust brass housing with nickel=plated fine thread M8 x 1 IM 12 NAMUR


    Original
    M12x1 IM12-02B-N-ZW0 IM12-04N-N-ZW0 Namur isolating switching amplifier namur output DIN19234 IM12-02B-N-ZW0 IM12-04N-N-ZW0 PDF