Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RESIDUAL CURRENT BREAKER Search Results

    RESIDUAL CURRENT BREAKER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TLX9188 Toshiba Electronic Devices & Storage Corporation Photocoupler (phototransistor output), DC input, 3750 Vrms, SO6, Automotive Visit Toshiba Electronic Devices & Storage Corporation
    TPD4207F Toshiba Electronic Devices & Storage Corporation Intelligent power device 600V (High voltage PWM DC brushless motor driver) Visit Toshiba Electronic Devices & Storage Corporation
    TPD4204F Toshiba Electronic Devices & Storage Corporation Intelligent power device 600V (High voltage PWM DC brushless motor driver) Visit Toshiba Electronic Devices & Storage Corporation
    TLP294-4 Toshiba Electronic Devices & Storage Corporation Photocoupler (phototransistor output), AC input, 3750 Vrms, 4 channel, SO16 Visit Toshiba Electronic Devices & Storage Corporation
    TLP295-4 Toshiba Electronic Devices & Storage Corporation Photocoupler (phototransistor output), DC input, 3750 Vrms, 4 channel, SO16 Visit Toshiba Electronic Devices & Storage Corporation

    RESIDUAL CURRENT BREAKER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    ABB SHUNT TRIP diagram electrical connection

    Abstract: EARTH LEAKAGE circuit-breakers ABB SHUNT TRIP F804 stotz sk Switchboard star delta connections residual current device bbn 63 VDE 0106 PART 100
    Text: Technical data Residual Current-operated Circuit-Breakers Residual Current-operated F 804 Circuit-Breakers F 804 SK 5 ABB STOTZ-KONTAKT 1 Residual Current-operated Circuit-Breakers F 804 Aluminium conductors must not be connected Conditions of Delivery and Sale


    Original
    PDF R2590 R4590 S0002 D-69006 D-69123 ABB SHUNT TRIP diagram electrical connection EARTH LEAKAGE circuit-breakers ABB SHUNT TRIP F804 stotz sk Switchboard star delta connections residual current device bbn 63 VDE 0106 PART 100

    1492-RCD2A16

    Abstract: 1492-RCD4C40 1492-rcd2a25 1492-RCD4C63 1492-RCD 1492-RCD4C25 1492-RCD4D25 1492-RCD4C40D 1492-RCD2A40 1492-RCD2C25
    Text: Residual Current Devices SELECTION GUIDE Bulletin 1492-RCD Bulletin 1492 Residual Current Devices Product Overview/Description/Product Selection Table Bulletin 1492 — Residual Current Devices Table of Contents Earth Leakage Detectors for IEC Applications


    Original
    PDF 1492-RCD 1492-RCD 1492-SP) 1492-SG006B-EN-P 1492-SG006A-EN-P 1492-RCD2A16 1492-RCD4C40 1492-rcd2a25 1492-RCD4C63 1492-RCD4C25 1492-RCD4D25 1492-RCD4C40D 1492-RCD2A40 1492-RCD2C25

    merlin gerin rcd

    Abstract: merlin gerin Earth Leakage earth leakage circuit breaker 30 mA merlin gerin merlin gerin 23146 23146 Merlin Gerin Merlin Gerin circuit breakers BSEN61008 4p 63a 30ma 4P 63A MERLIN
    Text: RMG residual current devices Ratings: 16 - 100A Sensitivities: 10 - 300mA, time delayed Application Type RMG residual current devices provide the functions of isolation, switching and earth leakage protection of electrical circuits. They have a residual current operated


    Original
    PDF 300mA, 300mA. 100mA merlin gerin rcd merlin gerin Earth Leakage earth leakage circuit breaker 30 mA merlin gerin merlin gerin 23146 23146 Merlin Gerin Merlin Gerin circuit breakers BSEN61008 4p 63a 30ma 4P 63A MERLIN

    F204A

    Abstract: F202A F204AC-63 ABB MCB F202AC residual current device ABB SHUNT TRIP F204AC ABB Main Circuit breaker F200A
    Text: F200 Series Residual Current Devices Residual current devices F200 Series UL 1053 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Description The F200 Series residual current devices offer a wide range of product for all of your fault


    Original
    PDF F200Atical, 480Y/277 F204A F202A F204AC-63 ABB MCB F202AC residual current device ABB SHUNT TRIP F204AC ABB Main Circuit breaker F200A

    NHXSBS1C16

    Abstract: NHXSBS1C06 NHXSBS1C50
    Text: DATA SHEET FOR 1 MODULE RCBO Catalogue Numbers: NHXSBS1C06, NHXSBS1C10, NHXSBS1C16, NHXSBS1C20, NHXSBS1C32, NHXSBS1C40 and NHXSBS1C50 • Poles Residual current circuit breaker with over current protection 1P+ Solid Neutral Rated current In 6A to 50A • Residual current


    Original
    PDF NHXSBS1C06, NHXSBS1C10, NHXSBS1C16, NHXSBS1C20, NHXSBS1C32, NHXSBS1C40 NHXSBS1C50 20000/10000ty 0000A NHXSBS1C16 NHXSBS1C06 NHXSBS1C50

    400a mccb DATASHEET

    Abstract: AC690 AC400
    Text: UEM5Z2 series electronic MCCB with residual current protection UEM5Z2 Series electronic molded case circuit breakers with residual current protection circuit breakers for short below are applicable to the electrical network under the condition of AC50Hz/ AC60Hz, rated working current


    Original
    PDF AC50Hz/ AC60Hz, capacit100M 0100A UEM5Z2-225L 00225A UEM5Z2-225M UEM5Z2-400L AC690 AC400 400a mccb DATASHEET AC690 AC400

    AC690

    Abstract: 690V electric motor
    Text: UEM5L series molded case circuit breakers with residual current protection UEM5L Series molded case circuit breakers with residual current protection circuit breakers for short below are applicable to the electrical network under the condition of AC50Hz/60Hz, rated working current


    Original
    PDF AC50Hz/60Hz, -100M UEM5L-160M UEM5L-160L UEM5L-225L UEM5L-225M UEM5L-400L AC690 AC400 UEM5L-400M AC690 690V electric motor

    IC60H

    Abstract: CA907021 IC60N C CURVE A9F44220 IC60N 1P N SEA9BN24TN A9C32811 merlin gerin RCBO A9C64216 telemecanique contactor catalogue
    Text: Low voltage Acti 9 the efficiency you deserve Catalogue 2013 Acti 9 The safest, simplest and most efficient system for power distribution solutions Protection devices > Miniature circuit breaker > Residual current circuit breaker > Vigi residual current devices


    Original
    PDF SE7856 IC60H CA907021 IC60N C CURVE A9F44220 IC60N 1P N SEA9BN24TN A9C32811 merlin gerin RCBO A9C64216 telemecanique contactor catalogue

    IC60H

    Abstract: SEA9NTB2504 SEA9BN24TN A9D11806 merlin gerin isobar 4c A9F54350 DB118787 SEA9AN10PS Vigi iC60 advantages of earth leakage circuit breaker
    Text: Low voltage Acti 9 the efficiency you deserve Catalogue 2013 Acti 9 The safest, simplest and most efficient system for power distribution solutions Protection devices > Miniature circuit breaker > Residual current circuit breaker > Vigi residual current devices


    Original
    PDF SE7856 IC60H SEA9NTB2504 SEA9BN24TN A9D11806 merlin gerin isobar 4c A9F54350 DB118787 SEA9AN10PS Vigi iC60 advantages of earth leakage circuit breaker

    ELCB wiring diagram

    Abstract: ELCB circuit breaker 3 Phase wiring diagram of rccb ELCB ELCB DATASHEET elcb connections flow diagram 3 phase ELCB ELCB 4 pole ELCB 3 pole tripping curve of elcb
    Text: com.greegoo.www Greegoo Elextric Co.,Ltd. 2007 Residual Current Devices Introduction Residential Final Distribution 1- Residual Current Devices RCD Against electrocution 1 The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed


    Original
    PDF

    k30206

    Abstract: SENSOR HALL 946 s 452 kd 2060 transistor
    Text: Complete Catalogue 4/2015 Residual current monitoring in grounded power supply systems with residual current relay type RCM1000V and current transformers type STWA3D Meas uring, C ontr olling, Moni t o r i n g o n h i g h e s t l e v e l Editorial Besser, schneller, innovativer, das ist unsere Maxime bei


    Original
    PDF RCM1000V D-74523 k30206 SENSOR HALL 946 s 452 kd 2060 transistor

    Untitled

    Abstract: No abstract text available
    Text: Philips Semiconductors Product specification Thyristors logic level for RCD/ GFI/ LCCB applications GENERAL DESCRIPTION Passivated, sensitive gate thyristors in a plastic envelope, intended for use in Residual Current Devices/ Ground Fault Interrupters/ Leakage Current


    Original
    PDF BT168

    neutral earth BUSBAR calculation

    Abstract: earth BUSBAR calculation earth BUSBAR type b mcb rcbo rcbo type ac 610092-2 motor current mcb tripping BUSBAR calculation 20A SINGLE POLE MCB
    Text: TECHNICAL DATA SHEET Sentry Residual Current Breakers with Overcurrent Protection RCBOs 1:2 Sentry RCBOs Description PRODUCT RANGE Rating Tripping current List No. The Sentry range features solid neutral type single pole RCBOs in one module format. 6A, 230V


    Original
    PDF 6932s 6933s 6934s 6935s 6936s 6937s 6938s neutral earth BUSBAR calculation earth BUSBAR calculation earth BUSBAR type b mcb rcbo rcbo type ac 610092-2 motor current mcb tripping BUSBAR calculation 20A SINGLE POLE MCB

    AEG elfa e81s

    Abstract: aeg elfa e82s c10 AEG elfa e81s C40 AEG elfa miniature circuit breaker E81S IP557 E83S MINIATURE CIRCUIT BREAKER AEG b40 e82s aeg b40
    Text: ELFA MINIATURE CIRCUIT BREAKERS Standard Accesories CATALOG NO. 6. The modular equipment program Elfa miniature circuit breakers can be combined with residual-current trips, remote-control drives and auxiliary contacts. As variants they are also intended for direct-current systems,


    Original
    PDF ELFA-714 ELFA-085 ELFA-760 ELFA-947 ELFA-940 ELFA-80904 ELFA-931 ELFA-932 ELFA-933 AEG elfa e81s aeg elfa e82s c10 AEG elfa e81s C40 AEG elfa miniature circuit breaker E81S IP557 E83S MINIATURE CIRCUIT BREAKER AEG b40 e82s aeg b40

    IEC 60947-3

    Abstract: ITG40 IEC 60947-3 standards 61008 schneider circuit breaker
    Text: Fiche produit Caractéristiques A9N21522 ProDis residual current circuit breaker ITG40 2 poles - 25 A - class AC 300 mA Range of product ProDis Device short name ITG40 Poles description 2P Neutral position Left [In] rated current 25 A Network type AC Earth-leakage protection time delay


    Original
    PDF A9N21522 ITG40 ITG40 IEC 60947-3 IEC 60947-3 standards 61008 schneider circuit breaker

    A9N21520

    Abstract: iec 60947-3 IEC 60947-3 standards
    Text: Fiche produit Caractéristiques A9N21520 ProDis residual current circuit breaker ITG40 2 poles - 25 A - class AC 30 mA Range of product ProDis Device short name ITG40 Poles description 2P Neutral position Left [In] rated current 25 A Network type AC Earth-leakage protection time delay


    Original
    PDF A9N21520 ITG40 ITG40 A9N21520 iec 60947-3 IEC 60947-3 standards

    BT168 600

    Abstract: BT151 BT168 BT169 it889
    Text: Philips Semiconductors Product specification Thyristors logic level for RCD/ GFI/ LCCB applications GENERAL DESCRIPTION Glass passivated, sensitive gate thyristors in a plastic envelope, intended for use in Residual Current Devices/ Ground Fault Interrupters/


    Original
    PDF BT168 BT168 BT168 600 BT151 BT169 it889

    IEC 60947-3 standards

    Abstract: 61008 IEC 60947-3 ITG40
    Text: Fiche produit Caractéristiques A9N21521 ProDis residual current circuit breaker ITG40 2 poles - 40 A - class AC 30 mA Range of product ProDis Device short name ITG40 Poles description 2P Neutral position Left [In] rated current 40 A Network type AC Earth-leakage protection time delay


    Original
    PDF A9N21521 ITG40 ITG40 IEC 60947-3 standards 61008 IEC 60947-3

    Untitled

    Abstract: No abstract text available
    Text: Philips Semiconductors Product specification Thyristors logic level for RCD/ GFI/ LCCB applications GENERAL DESCRIPTION Passivated, sensitive gate thyristors in a plastic envelope suitable for surface mounting, intended for use in Residual Current Devices/


    Original
    PDF BT168W BT168

    RCBO

    Abstract: stotz rcbo type ac ABB/stotz aluminium profile stotz sk
    Text: Installation and operating instructions Residual Current-operated Circuit Breakers with overcurrent protection RCBO Type DS 261 / DS 271 GH D270 7021 P2 ABB STOTZ-KONTAKT GmbH P.O. Box 101 680, D-69006 Heidelberg Phone (06221) 701-0, Fax (06221) 701 723


    Original
    PDF D-69006 RCBO stotz rcbo type ac ABB/stotz aluminium profile stotz sk

    ABB Main Circuit breaker

    Abstract: stotz sk FUSE GL RCBO heidelberg circuit stotz s FS451
    Text: Installation and operation instructions Connection STOTZ Residual Current Operated Circuit Breaker with Overcurrent Release FS 451 T Incoming supply is connected by means of ”Safe Connect” plug-in technology. RCBO according to DIN VDE 0664 Part 2 and EN 61009


    Original
    PDF D-69006 ABB Main Circuit breaker stotz sk FUSE GL RCBO heidelberg circuit stotz s FS451

    RCBO

    Abstract: F450 ABB Main Circuit breaker heidelberg circuit
    Text: Installation and operation instructions Connection STOTZ Residual Current Operated Circuit Breaker with Overcurrent Release FS 452 Incoming supply is connected by means of ”Safe Connect” plug-in technology. RCBO according to DIN VDE 0664 Part 2 and EN 61009


    Original
    PDF D-69006 RCBO F450 ABB Main Circuit breaker heidelberg circuit

    Untitled

    Abstract: No abstract text available
    Text: 8 | PC-Series - Introduction PC-Series Ground Fault Circuit Protection The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection RCBO , combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Philips Semiconductors Product specification Thyristors BT168 series logic level for RCD/ GFI/ LCCB applications_ GENERAL DESCRIPTION Glass passivated, sensitive gate thyristors in a plastic envelope, intended for use in Residual Current


    OCR Scan
    PDF BT168 D-067