Untitled
Abstract: No abstract text available
Text: CCD231-C6 Back Illuminated Scientific CCD Sensor 6144 x 6160 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging
|
Original
|
PDF
|
CCD231-C6
CCD231
A1A-777755
|
Untitled
Abstract: No abstract text available
Text: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs, Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging
|
Original
|
PDF
|
CCD231-84
CCD231
A1A-765136
|
Glenair micro
Abstract: CCD231 CCD230 GE-56
Text: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging
|
Original
|
PDF
|
CCD231-84
CCD231
A1A-765136
Glenair micro
CCD230
GE-56
|
Untitled
Abstract: No abstract text available
Text: CCD230-84 Scientific CCD Sensor Front Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low
|
Original
|
PDF
|
CCD230-84
CCD230
A1A-100049
|
CCD230-84
Abstract: Fenwal NTC 196-LAD302-002 CCD230 CCD231 4096H H2E1 capacitive readout circuit
Text: CCD230-84 Scientific CCD Sensor Front Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low
|
Original
|
PDF
|
CCD230-84
CCD230
A1A-100049,
Fenwal NTC
196-LAD302-002
CCD231
4096H
H2E1
capacitive readout circuit
|
CCD230
Abstract: CCD230-42
Text: CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low
|
Original
|
PDF
|
CCD230-42
CCD230
A1A-765137
|
CCD230-42
Abstract: No abstract text available
Text: CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low
|
Original
|
PDF
|
CCD230-42
CCD230
A1A-765137
|
Untitled
Abstract: No abstract text available
Text: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging
|
Original
|
PDF
|
CCD231-84
CCD231
A1A-765136
|
tri linear CCD
Abstract: Glenair micro CCD230 CCD231
Text: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs, Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging
|
Original
|
PDF
|
CCD231-84
CCD231
A1A-765136
tri linear CCD
Glenair micro
CCD230
|
Untitled
Abstract: No abstract text available
Text: CCD230-84 Scientific CCD Sensor Back Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low readout
|
Original
|
PDF
|
CCD230-84
CCD230
A1A-764199
|
196-LAD302-002
Abstract: No abstract text available
Text: CCD230-84 Scientific CCD Sensor Back Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low readout
|
Original
|
PDF
|
CCD230-84
CCD230
A1A-764199
196-LAD302-002
|
CCD230-42
Abstract: ccd sensor back illuminated ccd231 common rail CCD230
Text: CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out
|
Original
|
PDF
|
CCD230-42
CCD230
A1A-765138
ccd sensor back illuminated
ccd231
common rail
|
CCD230
Abstract: CCD230-42
Text: CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out
|
Original
|
PDF
|
CCD230-42
CCD230
A1A-765138
|
CCD230-42
Abstract: No abstract text available
Text: CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out
|
Original
|
PDF
|
CCD230-42
CCD230
A1A-765138
|
|
Untitled
Abstract: No abstract text available
Text: R Digital CMOS camera C11440-10C Technical Note April 2015 1. Introduction P3 2. Scientific CMOS Image Sensor FL-280 P3 2.1. CCD image sensor vs. Scientific CMOS Image Sensor FL-280 2.1.1. Structure of CCD image sensor and CMOS image sensor 2.1.2. CCD image sensor vs. conventional CMOS image sensor
|
Original
|
PDF
|
C11440-10C
FL-280
B1201
SCAS0070E02
APR/2015
|
3D scanner
Abstract: Piezo Electric pzt Piezo Ceramic plates
Text: Agilent 5420 SPM/AFM Microscope Data Sheet Introducing The Agilent Technologies 5420 Scanning Probe Microscope SPM Features and Benefits • Scientific-grade instrument delivers atomic resolution • New design provides improved performance • New electronics and techniques
|
Original
|
PDF
|
5990-3848EN
3D scanner
Piezo Electric pzt
Piezo Ceramic plates
|
Untitled
Abstract: No abstract text available
Text: Keysight Technologies N9320B Spectrum Analyzer The Most Cost-effective RF Measurement Instrument for the Manufacture of Consumer Wireless Electronics Introduction Since the Industrial, Scientific and Medical ISM 2.4 GHz frequency band is the most universal, unlicensed RF band
|
Original
|
PDF
|
N9320B
BP-09-23-14)
E3632A
4401A
5989-8798EN
|
SM2327-47
Abstract: gaas amplifier
Text: Specification Sheet for SM2327-47 SSPA This solid state GaAs amplifier is designed for Industrial, Scientific, Medical band market. By using the latest surface mount technologies, this small amplifier can easily fit into tightly packed transmitters and repeaters.
|
Original
|
PDF
|
SM2327-47
SM2327-47
com/specs/2325-47/2325
gaas amplifier
|
Untitled
Abstract: No abstract text available
Text: BCN168RB summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN168RB array is 0.007 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Homogeneous Material Name Substrate Alumina Thick film
|
Original
|
PDF
|
BCN168RB
123E-2
123E-03
000E-05
330E-04
200E-05
000E-06
|
Untitled
Abstract: No abstract text available
Text: Agilent 5420 SPM/AFM Microscope Data Sheet Introducing The Agilent Technologies 5420 Scanning Probe Microscope SPM Features and Benefits • Scientific-grade instrument delivers high resolution • New design provides improved performance • New electronics and techniques
|
Original
|
PDF
|
5990-3848EN
|
Untitled
Abstract: No abstract text available
Text: BCN218SBI summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN218SBI array is 0.017 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Substrate Thick film Termination Homogeneous Material Name Material name
|
Original
|
PDF
|
BCN218SBI
459E-02
680E-04
160E-04
300E-05
530E-04
000E-06
000E-07
|
Untitled
Abstract: No abstract text available
Text: BCN4D summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN4D array is 0.028 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Substrate Thick film Termination Homogeneous Material Name Material name
|
Original
|
PDF
|
455E-02
830E-04
320E-04
900E-05
630E-04
400E-05
200E-05
000E-06
600E-05
100E-05
|
Untitled
Abstract: No abstract text available
Text: BCN164A summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN164A array is 0.007 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Substrate Thick film Termination Homogeneous Material Name Material name
|
Original
|
PDF
|
BCN164A
723E-03
600E-05
240E-04
100E-05
400E-05
000E-06
100E-07
|
HADC674Z
Abstract: HI674A
Text: HADC674Z @ SPT FAST, COMPLETE 12-BIT COMPATIBLE A/D CONVERTER WITH SAMPLE/HOLD SIGNAL PROCESSING TECHNOLOGIES APPLICATIONS FEATURES Military/Industrial Data Acquisition Systems 8 or 12-Bit J.P Input Functions Process Control Systems Test and Scientific Instruments
|
OCR Scan
|
PDF
|
HADC674Z
12-BIT
HI674A
12-Bit
HADC674Z
HI674A.
DBO-DB11
HI674A
|