    Sprecher Schuh CT 4-9

    Abstract: Sprecher Schuh LE 2-16 Sprecher Schuh CT 3-23 Sprecher Schuh ct 3 320/HT215/Sprecher Schuh CT 4-9
    Text: CEP7 Solid State Overload Relays Advanced solid state motor protection The introduction of the second generation of CEP7 solid state overload relays advances Sprecher + Schuh’s leading edge technology with several improved features. This second generation of CEP7


    Original
    SSNA2014 Sprecher Schuh CT 4-9 Sprecher Schuh LE 2-16 Sprecher Schuh CT 3-23 Sprecher Schuh ct 3 320/HT215/Sprecher Schuh CT 4-9 PDF

    Sprecher Schuh LE 2-20

    Abstract: Sprecher Schuh LE 2-12 Sprecher Schuh le2-12 LE2-20 Sprecher Schuh LE2-20 Sprecher Schuh LE2-16 Sprecher Schuh CT 3-23 LA2-G2853 T3168 Sprecher Schuh L2-16
    Text: Rotary Cam Switches Series L2 Rotary Cam Switches Technical Information K2 K27 Series R-Line Rotary Cam Switches Technical Information K35 K44 Custom Switches K51 K Rotary Cam Switches K1 Series L2 Rotary Cam Switches Sprecher + Schuh’s comprehensive line


    Original
    PDF

    Sprecher Schuh

    Abstract: Sprecher Schuh timer Sprecher Schuh L 2-20 sprecher iec 947 -3
    Text: RZ7-FS Electronic Timing Relays Precision DIN-rail mounted timing relays for any industrial application RZ7 Timing Relays G Sprecher + Schuh’s new RZ7-FS precision electronic timing relays offer 19 different output functions applicable to all types of industrial control. In


    Original
    SSNA2014 Sprecher Schuh Sprecher Schuh timer Sprecher Schuh L 2-20 sprecher iec 947 -3 PDF

    E Catalog

    Abstract: ecatalog RZ7-FEB1SU22
    Text: RZ7-FE Electronic Timing Relays The economical choice for most industrial timing applications Sprecher + Schuh’s RZ7-FE electronic timing relays offer seven popular output functions in an economical package. This series is especially designed for applications where a high quality,


    Original
    SSNA2014 E Catalog ecatalog RZ7-FEB1SU22 PDF

    Sprecher Schuh

    Abstract: 220 volt ac transformer less power supply 90v 110 volt ac transformer less power supply 90v SAR6-50-1 SAR6-30-3D 12 volt dc to 220 volt 3-phase 400 Hz 3000 watts slip ring motor characteristics curve normal SLIP led 3 volt SAR6-75-1 5 leg relay free
    Text: Series SAR S Solid State Relays Reliable performance for millions of operations Sprecher + Schuh’s SAR(S) line of solid state relays are the ideal solution for applications where high speed switching and long life are essential. In specific applications, solid state relays


    Original
    PDF

    Sprecher Schuh LE 2-20

    Abstract: Sprecher Schuh LE 2-12 Sprecher Schuh LE 2-25 sprecher schuh le2-16 cam switch Sprecher Schuh L2-16 Sprecher Schuh LE2-20 Sprecher Schuh LE2-16 LE2-20 Sprecher Schuh le2-12 Sprecher Schuh LE 2
    Text: Series L2 Rotary Cam Switches Sprecher + Schuh’s comprehensive line of L2 rotary cam switches are available for all control and load applications up to 25 amps. The line is modular and has many convenience and safety features. A well thought out ordering


    Original
    LA2-12/16 LA2-20/25 LA2-G3393 LA2-G3394 Sprecher Schuh LE 2-20 Sprecher Schuh LE 2-12 Sprecher Schuh LE 2-25 sprecher schuh le2-16 cam switch Sprecher Schuh L2-16 Sprecher Schuh LE2-20 Sprecher Schuh LE2-16 LE2-20 Sprecher Schuh le2-12 Sprecher Schuh LE 2 PDF

    VOLTMETER SELECTOR SWITCH

    Abstract: 3 phase 2 wire ct ammeter wiring 194L-E16-1753-6N 194EY 194L-E12 ammeter selector 194L-E25-1754-6N 194L-HE Allen-Bradley bulletin 705 194C-C10
    Text: Control and Load Switches Complete Switches Pages 12-6.12-8 • Main Switches / EMERGENCY OFF Switches • Series Q • 194E Series B Load Switch, Type Q for Installation in Distribution Cubicle • 194E Series B Load Switch / EMERGENCY OFF, Type R for Installation in Distribution


    Original
    194E-80/100 194E-E 194E-Y 194L-G3572 194L-G3576 194E-G3663 194E-G3664 VOLTMETER SELECTOR SWITCH 3 phase 2 wire ct ammeter wiring 194L-E16-1753-6N 194EY 194L-E12 ammeter selector 194L-E25-1754-6N 194L-HE Allen-Bradley bulletin 705 194C-C10 PDF

    Allen-Bradley 100-c09*10

    Abstract: Sprecher Schuh CA 4-5-10 Sprecher Schuh CT 3-12 Sprecher Schuh CA 4-9-10 Sprecher Schuh CA 3-12 Sprecher Schuh 100-c72 00 100-C60 00 Allen-Bradley c09-10 Allen-Bradley 100-C16 10
    Text: Mini-Contactors and Contactors • Bulletin 100-M / CA 4 • Bulletin 100-C • Bulletin CAB6 / CA 6 2.5 . 4.3 kW 4 . 45 kW 47 . 238 kW Overview . 4-2 Product Selection AC Control . 4-4


    Original
    100-M 100-C 6-250-PS CAB6-250-PS 6-250-PU CAB6-250-PU 6-250-PY CAB6-250-PY 6-105-PY CAB6-105-PY Allen-Bradley 100-c09*10 Sprecher Schuh CA 4-5-10 Sprecher Schuh CT 3-12 Sprecher Schuh CA 4-9-10 Sprecher Schuh CA 3-12 Sprecher Schuh 100-c72 00 100-C60 00 Allen-Bradley c09-10 Allen-Bradley 100-C16 10 PDF

    GV3-ME40

    Abstract: GV3-ME63 Telemecanique GV3ME63 Motor Circuit Breaker GV3ME63 GV3ME40 RSHR4025CV20 telemecanique GV2-M22 Telemecanique circuit breaker GV3ME40 telemecanique thermal overload relay KTA3-25-25A
    Text: Motor Controllers AC Semiconductor Motor Controller Type RSHR • Soft starting and stopping of 3-phase squirrel cage motors • Low inrush and reduced vibration during starting • Integrated bypassing of semiconductors • Rated operational voltage: up to 600 VAC, 50/60 Hz


    Original
    AC-53b GV3-ME40 GV3-ME63 Telemecanique GV3ME63 Motor Circuit Breaker GV3ME63 GV3ME40 RSHR4025CV20 telemecanique GV2-M22 Telemecanique circuit breaker GV3ME40 telemecanique thermal overload relay KTA3-25-25A PDF

    GV3-ME40

    Abstract: Telemecanique GV3ME63 Motor Circuit Breaker GV3-ME63 RSHR4038CV20 rshr4045 GV3ME63 GV2-M22 Telemecanique circuit breaker GV3ME40
    Text: Motor Controllers AC Semiconductor Motor Controller Type RSHR • Soft starting and stopping of 3-phase squirrel cage motors • Low inrush and reduced vibration during starting • Integrated bypassing of semiconductors • Rated operational voltage: up to 600 VAC, 50/60 Hz


    Original
    AC-53b GV3-ME40 Telemecanique GV3ME63 Motor Circuit Breaker GV3-ME63 RSHR4038CV20 rshr4045 GV3ME63 GV2-M22 Telemecanique circuit breaker GV3ME40 PDF

    kta 3-25

    Abstract: Allen-Bradley 100-M09 KTL-3-65-N Allen-Bradley Overload relay 140-MN-1600 Allen-Bradley cat 140-mn-0400 Allen-Bradley Overload relay 140-MN-0250 Allen-Bradley cat 140-mn-1000 140M-K5F-D12 140M-K5F-D16 kry 112 76 1
    Text: Circuit-Breakers Bulletin 140 / KTA 3 Bulletin 140 / KTA 3 • • • • Motor Protection Characteristics High Switching Capacity High Current Limiting For Compact Motor Starters Overview . 2-2


    Original
    140-MN 140-CMN 140M-K5F 3-160S 140M-M5F 3-250S 140M-P5F 3-400S 140M-K5F 3-160S) kta 3-25 Allen-Bradley 100-M09 KTL-3-65-N Allen-Bradley Overload relay 140-MN-1600 Allen-Bradley cat 140-mn-0400 Allen-Bradley Overload relay 140-MN-0250 Allen-Bradley cat 140-mn-1000 140M-K5F-D12 140M-K5F-D16 kry 112 76 1 PDF

    LR2-D13 Telemecanique

    Abstract: ca2-Dn22 Telemecanique telemecanique LR2-D13 telemecanique lr2 d13 telemecanique LA1 DN22 Sprecher Schuh ca3 elevator schematic telemecanique contactor catalogue Telemecanique LC1k06 telemecanique overload relay
    Text: O.THOMPSON COMPANY 8400 73rd Avenue - Unit F - Glendale, N.Y. 11385 Phone: 718 417-3131 Fax: (718) 417-5363 Designers and Manufacturers of Microflite and Tricon Elevator Controls Tricon ELON 1000 Parts Catalog Tricon ELON 1000 Parts Catalog Revision April 14, 2003


    Original
    LCA10S-5 T12-0002-10 LR2-D13 Telemecanique ca2-Dn22 Telemecanique telemecanique LR2-D13 telemecanique lr2 d13 telemecanique LA1 DN22 Sprecher Schuh ca3 elevator schematic telemecanique contactor catalogue Telemecanique LC1k06 telemecanique overload relay PDF

    GV3-ME63

    Abstract: GV3-ME40 telemecanique magnetic contactor telemecanique soft start motor control diagram telemecanique limit switch telemecanique overload relay telemecanique kta3-25 telemecanique gv2 11KW motor telemecanique GV2-M22
    Text: Motor Controllers AC Semiconductor Motor Controller Type RSHR • Soft starting and stopping of 3-phase squirrel cage motors • Low inrush and reduced vibration during starting • Integrated bypassing of semiconductors • Rated operational voltage: up to 600 VAC, 50/60 Hz


    Original
    AC-53b GV3-ME63 GV3-ME40 telemecanique magnetic contactor telemecanique soft start motor control diagram telemecanique limit switch telemecanique overload relay telemecanique kta3-25 telemecanique gv2 11KW motor telemecanique GV2-M22 PDF

    Legrand

    Abstract: connectwell VP-500 Allen-Bradley Sprecher Schuh VP500 Legrand x royal Sprecher ABB Semiconductors
    Text: Plotter System VP-500 • • • • • All marker types printed Automatic detection of removable template Error proof positioning of templates Windows based program Identifiers for Connectors, Wires, Cables and Equipment • Custom ties, special shrink tubing, labels


    Original
    VP-500 Legrand connectwell VP-500 Allen-Bradley Sprecher Schuh VP500 Legrand x royal Sprecher ABB Semiconductors PDF

    CA3-9-10

    Abstract: Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 Sprecher Schuh ca3-16-10 CA3-12-10 Sprecher Schuh TE404 ca3 contactor CA3-16-10
    Text: Accessories – Field Installable CA7 Contactors Contact Block Description NO NC Contact Arrangement Standard Contacts Catalog For use with. Number Bifurcated Contacts Catalog Price Number ➋ Price 51 61 2 CA7 all CS7-PV-02 27 CS7-PVB-02 42 CA7-30.97-✱-00


    Original
    CS7-PVB-02 CA7-PV-02 CA7-PVB-02 CS7-PV-11 CS7-PVB-11 CA7-30. CA7-PV-11 CA7-PVB-11 CA7-PV-S11 CA7-PVB-S11 CA3-9-10 Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 Sprecher Schuh ca3-16-10 CA3-12-10 Sprecher Schuh TE404 ca3 contactor CA3-16-10 PDF

    Sprecher Schuh LE 2-16

    Abstract: TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719
    Text: Contactors - AC Coil Four Pole - Series CA7 A Non-Reversing, Four Pole Contactors With AC Coil, Series CA7 Open type only Contactors Ratings for Switching AC Motors (AC2 / AC3 / AC4) Open Type Contact Configuration, Ie [A] kW (50 Hz) UL/CSA HP (60 Hz) Main Pole Catalog


    Original
    CA7-9-M40- CA7-9-M31- CA7-9-M22- CA7-12-M40- CA7-12-M31- CA7-12-M22- Sprecher Schuh LE 2-16 TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719 PDF

    Sprecher Schuh LE 2-16

    Abstract: Sprecher Schuh CS1 Sprecher Schuh timer Sprecher Schuh LE 2-20
    Text: G Control & Timing Relays Control & Timing Relays CS7 Industrial Control Relays. G2 Technical Information. G17


    Original
    RM699 SSNA9000 Sprecher Schuh LE 2-16 Sprecher Schuh CS1 Sprecher Schuh timer Sprecher Schuh LE 2-20 PDF

    Allen-Bradley 1794-ie8 manual

    Abstract: Allen-Bradley 1794-ib16 Allen-Bradley 1794-ob16 Allen-Bradley 1794-it8 WIRING 1794-IE8 1794 oe4 1794 IE8 1794-IE8 1794IE8 connection 1794-IB16
    Text: Allen-Bradley FLEX I/O PROFIBUS Adapter User Manual Cat. No. 1794-APB –2 Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. “Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls”


    Original
    1794-APB) Allen-Bradley 1794-ie8 manual Allen-Bradley 1794-ib16 Allen-Bradley 1794-ob16 Allen-Bradley 1794-it8 WIRING 1794-IE8 1794 oe4 1794 IE8 1794-IE8 1794IE8 connection 1794-IB16 PDF

    telemecanique overload relay

    Abstract: abb motor 3 phase 7.5 hp induction motor winding diagram 3 phase squirrel cage induction motor kta3-25 Telemecanique GV 2 ac induction motor of .25 HP Sprecher Schuh RSE4025-C RSE4025-C10
    Text: Motor Controllers AC Semiconductor Motor Controller Types RSE 22 25 - C., RSE 4. 25 - C., RSE 60 25 - C. • Soft starting and stopping of 3-phase squirrel cage motors • Rated operational voltage: Up to 600 VACrms, 50/60 Hz • Rated operational current: 25 AAC 53 b


    Original
    325Manufacturer KTA3-25Manufacturer telemecanique overload relay abb motor 3 phase 7.5 hp induction motor winding diagram 3 phase squirrel cage induction motor kta3-25 Telemecanique GV 2 ac induction motor of .25 HP Sprecher Schuh RSE4025-C RSE4025-C10 PDF

    sprecher schuh KTA 3-25

    Abstract: telemecanique overload relay Sprecher schuh kta 3 phase 7.5 hp induction motor winding diagram Ferraz 660-GRB KTA 3-25 sprecher kta 3-25 telemecanique soft start motor control diagram telemecanique magnetic contactor telemecanique overload
    Text: Motor Controllers AC Semiconductor Motor Controller Types RSE 22 . - B, RSE 4. . - B, RSE 60 . - B • Soft starting and stopping of 3-phase squirrel cage motors • Rated operational voltage: Up to 600 VACrms, 50/60 Hz • Rated operational current: 3 A or 12 AAC 53 b


    Original
    PDF

    sprecher schuh KTA 3-25

    Abstract: Ferraz 660-GRB kta 3-25 Sprecher Schuh typ KTA 3-25 Sprecher schuh kta Telemecanique GV 2 Sprecher Schuh L2 16 sprecher kta 3-25 IEC 947 2 kta 3-25 sprecher
    Text: Elektronische Motor-Steuergeräte Elektronische Motorstarter Typen RSE 23 . - B, RSE 4. . - B, RSE 60 . - B • Sanftanlauf und -auslauf von Drehstrom-Asynchronmotoren • Nenn-Betriebsspannung: Bis zu 600 VAC, 50/60 Hz • Nenn-Betriebsstrom: 3 A oder 12 A AC 53 b


    Original
    Nenn-B270/480 sprecher schuh KTA 3-25 Ferraz 660-GRB kta 3-25 Sprecher Schuh typ KTA 3-25 Sprecher schuh kta Telemecanique GV 2 Sprecher Schuh L2 16 sprecher kta 3-25 IEC 947 2 kta 3-25 sprecher PDF

    sprecher schuh KTA 3-25

    Abstract: 3 phase 7.5 hp induction motor winding diagram telemecanique overload relay kta 3-25 Sprecher Schuh sprecher kta 3-25 Sprecher Schuh Type KTA 3-25 3 phase 7.5 hp induction motor winding telemecanique overload telemecanique contactor
    Text: Motor Controllers AC Semiconductor Motor Controller Types RSE 22 . - B, RSE 4. . - B, RSE 60 . - B • Soft starting and stopping of 3-phase squirrel cage motors • Rated operational voltage: Up to 600 VACrms, 50/60 Hz • Rated operational current: 3 A or 12 AAC 53 b


    Original
    PDF

    sprecher schuh KTA 3-25

    Abstract: 3 phase 7.5 hp induction motor winding diagram kta 3-25 sprecher kta 3-25 kta 3-25 sprecher telemecanique overload relay Sprecher schuh kta Sprecher Schuh Telemecanique GV 2 overload protection of induction motor
    Text: Type Rated operational voltage Ue RSE: E-series, motor controller 22: 127/220 VACrms, 50/60 Hz 03: 3 A 40: 230/400 VACrms, 50/60 Hz 12: 12 A 48: 277/480 VACrms, 50/60 Hz Specifications are subject to change without notice 30.06.1999 Rated operational current Ie


    Original
    PDF

    sprecher schuh KTA 3-25

    Abstract: telemecanique overload relay kta 3-25 3 phase 7.5 hp induction motor winding diagram Sprecher Schuh Sprecher schuh kta Telemecanique GV 2 Ferraz 660-GRB Sprecher Schuh Type KTA 3-25 3 phase squirrel cage induction motor
    Text: Motor Controllers AC Semiconductor Motor Controller Types RSE 22 . - B, RSE 4. . - B, RSE 60 . - B • Soft starting and stopping of 3-phase squirrel cage motors • Rated operational voltage: Up to 600 VACrms, 50/60 Hz • Rated operational current: 3 A or 12 AAC 53 b


    Original