Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOCOUPLE TYPE K TEMPERATURE Search Results

    THERMOCOUPLE TYPE K TEMPERATURE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCTH022BE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function Visit Toshiba Electronic Devices & Storage Corporation
    TCTH021BE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type Visit Toshiba Electronic Devices & Storage Corporation
    TCTH011AE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=1μA / IDD=1.8μA / Push-pull type Visit Toshiba Electronic Devices & Storage Corporation
    TCTH022AE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Push-pull type / FLAG signal latch function Visit Toshiba Electronic Devices & Storage Corporation
    TCTH021AE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Push-pull type Visit Toshiba Electronic Devices & Storage Corporation

    THERMOCOUPLE TYPE K TEMPERATURE Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    type j thermocouple

    Abstract: type k thermocouple Calex C277C 277c
    Text: Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple Model 8611. This type J thermocouple to frequency converter


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: EL-WiFi-TC WiFi Thermocouple Data Logging Sensor FEATURES • Temperature data logging sensor with K type thermocouple probe and integrated display • Supports J,K,N,T type thermocouple probes • Easy sensor set-up using the free PC software application downloadable from www.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Low Cost Digital Thermometer Single or Dual Input Models with Type K Thermocouple Input HH10 Series 65 $ Basic Unit Model HH12 Dual Input TJFT72-K-SS-116G-6 thermocouple probe sold separately. The HH10 Series handheld thermometers feature Type K thermocouple input and are available


    Original
    PDF TJFT72-K-SS-116G-6 SC-GG-K-30-36,

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF RS232

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    Calex

    Abstract: type j thermocouple C277C 277c
    Text: Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple n Isolated Input to Output


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    circuito sensor capacitivo

    Abstract: rs232 schema rs 232 RS-232-Kabel psion rs232 IRZE ir 9027 termocoppia tipo k sonde thermocouple type S
    Text: VARIOUS OPERATING MODES EXEMPLES DE MODES DE FONCTIONNEMENT VERSCHIEDENE BETRIEBSARTEN ESEMPI DI MODALITA' DI FUNZIONAMENTO “K" type thermocouple Thermocouple de type "K" BLUE BLAU BLEU BLU BROWN BRAUN MARRON MARRONE + - „K"-Thermoelement Termocoppia tipo "K"


    Original
    PDF SL-750/S circuito sensor capacitivo rs232 schema rs 232 RS-232-Kabel psion rs232 IRZE ir 9027 termocoppia tipo k sonde thermocouple type S

    SUPER MCJ

    Abstract: No abstract text available
    Text: Thermocouple Input Super MCJ Analog Output, 1 mV per degree SMP or OST Connector SMCJ-J, SMCJ-K, SMCJ-T INSTRUCTION SHEET M-2813 Thermocouple-to-Analog Connector GENERAL DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal (Type J, K, or T) to a linear, compensated, amplified analog


    Original
    PDF M-2813 SUPER MCJ

    psion workabout lcd

    Abstract: circuito sensor capacitivo tadiran
    Text: GB F VARIOUS OPERATING MODES EXEMPLES DE MODES DE FONCTIONNEMENT D I VERSCHIEDENE BETRIEBSARTEN ESEMPI DI MODALITA' DI FUNZIONAMENTO “K" type thermocouple Thermocouple de type "K" BLUE BLAU BLEU BLU BROWN BRAUN MARRON MARRONE + - „K"-Thermoelement Termocoppia tipo "K"


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Weller Type K Thermocouple Assembly With LTB Tip Product Details Catalog No. UPC Code Fits Tool s K1111 037103223821 WA2000 Type K Description Thermocouple for LTB Packaging Industrial Box/Carton Stock Item Normal Stock Item Package Details (Dimensions) Product Features:


    Original
    PDF K1111 WA2000 WA2000

    AD8495ARMZ-R7

    Abstract: Analog Devices, Inc Catalytic Converter k thermocouple amplification circuit diagram
    Text: Precision Thermocouple Amplifiers with Cold Junction Compensation AD8494/AD8495/AD8496/AD8497 FEATURES FUNCTIONAL BLOCK DIAGRAM REF APPLICATIONS J or K type thermocouple temperature measurement Setpoint controller Celsius thermometer Universal cold junction compensator


    Original
    PDF AD8494/AD8495/AD8496/AD8497 AD8494/AD8495/ AD8496/AD8497 D08529-0-6/11 AD8495ARMZ-R7 Analog Devices, Inc Catalytic Converter k thermocouple amplification circuit diagram

    AD8496

    Abstract: ad8495 AD8494 AD8497 Cold Junction Compensation Linear Thermometer ic Thermocouple Type K OVEN* temperature sensor cold junction human detection sensors circuit range from 1m
    Text: Precision Thermocouple Amplifiers with Cold Junction Compensation AD8494/AD8495/AD8496/AD8497 FEATURES FUNCTIONAL BLOCK DIAGRAM SENSE APPLICATIONS J or K type thermocouple temperature measurement Setpoint controller Celsius thermometer Universal cold junction compensator


    Original
    PDF AD8494/AD8495/AD8496/AD8497 AD8494/AD8495/ AD8496/AD8497 D08529-0-10/10 AD8496 ad8495 AD8494 AD8497 Cold Junction Compensation Linear Thermometer ic Thermocouple Type K OVEN* temperature sensor cold junction human detection sensors circuit range from 1m

    Untitled

    Abstract: No abstract text available
    Text: Economical Handheld Thermocouple Meters HH602 $ FREE! All temperature models include a free 36" type K beaded wire thermocouple with subminiature connector and wire spool caddy one per channel Order a Spare! Model No. SC-GG-K-30-36, $15 155 HH603 176 $ HH601


    Original
    PDF HH602 SC-GG-K-30-36, HH603 HH601 HH604, HH601, HH602 HH604 HH606,

    Untitled

    Abstract: No abstract text available
    Text: Isolated, Linearized, Thermocouple Input 3B47 FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation.


    Original
    PDF D05162-0-9/04

    k type thermocouple

    Abstract: thermocouple linearity AD8494 AD8495 AD8496 AD8497 Amplifier type K thermocouple AD8495ARMZ AD8495-ARMZ
    Text: Precision Thermocouple Amplifiers with Cold Junction Compensation AD8494/AD8495/AD8496/AD8497 FEATURES FUNCTIONAL BLOCK DIAGRAM REF APPLICATIONS J or K type thermocouple temperature measurement Setpoint controller Celsius thermometer Universal cold junction compensator


    Original
    PDF AD8494/AD8495/AD8496/AD8497 AD8494/AD8495/ AD8496/AD8497 D08529-0-4/11 k type thermocouple thermocouple linearity AD8494 AD8495 AD8496 AD8497 Amplifier type K thermocouple AD8495ARMZ AD8495-ARMZ

    AD595

    Abstract: AD595 thermocouple NICR-NI thermocouple ice point compensation feedback thermocouple AD594 AD594A AD594AD AD594C AD595A AD595C
    Text: a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594/AD595 FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation


    Original
    PDF AD594/AD595 AD594) AD595) O-116 AD595 AD595 thermocouple NICR-NI thermocouple ice point compensation feedback thermocouple AD594 AD594A AD594AD AD594C AD595A AD595C

    NICR-NI thermocouple

    Abstract: nicr-ni temperature Thermocouple Type K material 6790 pf 27 AD595A 680 ohms resistor 5 watt datasheet AD595 thermocouple cold junction compensation of t type thermocouple AD595 C731e
    Text: a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J AD594} or Type K (AD595 Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation


    Original
    PDF AD594 /AD595* AD594} AD595) AD594/AD595 O-116 NICR-NI thermocouple nicr-ni temperature Thermocouple Type K material 6790 pf 27 AD595A 680 ohms resistor 5 watt datasheet AD595 thermocouple cold junction compensation of t type thermocouple AD595 C731e

    circuit with thermocouple application

    Abstract: thermocouple connector pin thermocouple sensor thermocouple meter Amplifier type K thermocouple 0727 Cold Junction Compensation thermocouple Thermocouple circuit type t Amplifier k thermocouple
    Text: DTM 995 LCD Type K Thermocouple Indicator This meter will give a direct reading in °C from a K type chromel-alumel thermocouple sensor. The circuit uses a converter/amplifier which has Cold Junction Compensation. Calibration is by two 20-turn cermet potentiometers which allow sensitive adjustment of the


    Original
    PDF 20-turn August/2001 circuit with thermocouple application thermocouple connector pin thermocouple sensor thermocouple meter Amplifier type K thermocouple 0727 Cold Junction Compensation thermocouple Thermocouple circuit type t Amplifier k thermocouple

    NEDA 1604 6F22 006P

    Abstract: FLUKE 36 schematic diagram NEDA 1604 6F22 SAMA-CP45 80PK-2 6F22 9V calibration procedure for thermocouple Fluke Multimeter repair 741512 80PK-1
    Text: IF L U K E I — — — — Instruction Sheet 80TK Thermocouple Module INTRODUCTION Range Accuracy % of reading + degrees The Fluke 80TK is a thermocouple converter for use with any Ktype thermocouple and a digital multimeter (DMM). The 80TK accepts the output of any K-type thermocouple and converts it to


    OCR Scan
    PDF

    PM 8058

    Abstract: AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696
    Text: ANALOG DEVICES Monolithic Thermocouple Amplifiers with ColdJunction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-in Ice Point Compensation


    OCR Scan
    PDF AD594) AD595) AD594 /AD595* PM 8058 AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696