ANSI MC96.1
Abstract: MC96-1-82 ANSI MC96.1 TYPE T DSCA47J-01 EN50081-1 EN50082-1 ITS-90 monograph monograph 175
Text: DSCA47 Linearized Thermocouple Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each DSCA47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized, and converted
|
Original
|
PDF
|
DSCA47
DSCA47
DSCA47J-01
DSCA47J-01C
DSCA47J-01E
ANSI MC96.1
MC96-1-82
ANSI MC96.1 TYPE T
DSCA47J-01
EN50081-1
EN50082-1
ITS-90
monograph
monograph 175
|
NE-2H
Abstract: PWS740 ISO120 ISO120BG ISO120G ISO120SG ISO121 ISO121BG ISO121G PT100 table
Text: ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● ● ● ● ● ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION
|
Original
|
PDF
|
ISO120
ISO121
ISO120:
1500Vrms
ISO121:
3500Vrms
115dB
24-PIN
ISO120)
NE-2H
PWS740
ISO120
ISO120BG
ISO120G
ISO120SG
ISO121
ISO121BG
ISO121G
PT100 table
|
MPY100
Abstract: 1N4148 PWS740 free transistor data base book A.Z
Text: ISO122 Precision Lowest Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● 100% TESTED FOR HIGH-VOLTAGE BREAKDOWN ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator, Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation
|
Original
|
PDF
|
ISO122
1500Vrms
140dB
16-PIN
28-LEAD
ISO122
MPY100
1N4148
PWS740
free transistor data base book A.Z
|
x0605
Abstract: MC96-1-82 thermistor ntc 30k monograph 175 ANSI MC96.1 TYPE T AN505 AN701 EN50081-1 EN50082-1 Thermocouple Type K linearization
Text: SCM7B47 Isolated Linearized Thermocouple Input Modules FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B AND N THERMOCOUPLES SCM7B47 modules accept a single channel of input from Type J, K, T, E, R, S, B, or N thermocouples. The signal is filtered, isolated, amplified, linearized, and converted
|
Original
|
PDF
|
SCM7B47
SCM7B47
AN505.
1500Vr
x0605
MC96-1-82
thermistor ntc 30k
monograph 175
ANSI MC96.1 TYPE T
AN505
AN701
EN50081-1
EN50082-1
Thermocouple Type K linearization
|
Resistance characteristic Pt1000
Abstract: PT100 SENSOR rtd sensor pt100 temperature transmitter pt100 4-20ma atex Resistance characteristic Ni1000 PT1000 PT500 PT1000 thermocouple PT500 IEC 751 PT500 temperature sensor
Text: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-HT-T-I-Ex 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – For installation in Form B connection head POWER FL I
|
Original
|
PDF
|
|
k thermocouple amplification circuit diagram
Abstract: SCXI-1303 electromagnetic parking sensor SCXI-1100 thermocouple multiplexer constantan seebeck Table
Text: Application Note 056 How to Use Thermocouples with an SCXI-1100 Module This application note describes how to set up and use the SCXI-1100 with thermocouples. It also describes example programs that use the SCXI-1100 to make thermocouple measurements. These example programs are included on the SCXI Application Examples disk included in the
|
Original
|
PDF
|
SCXI-1100
k thermocouple amplification circuit diagram
SCXI-1303
electromagnetic parking sensor
thermocouple multiplexer
constantan seebeck Table
|
RTD PT100
Abstract: PWS740 ISO120 ISO120BG ISO120G ISO120SG ISO121 ISO121BG ISO121G
Text: ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● ● ● ● ● ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION
|
Original
|
PDF
|
ISO120
ISO121
ISO120:
1500Vrms
ISO121:
3500Vrms
115dB
24-PIN
ISO120)
RTD PT100
PWS740
ISO120
ISO120BG
ISO120G
ISO120SG
ISO121
ISO121BG
ISO121G
|
SCXI-1120D
Abstract: SCXI-1120 TBX-1329 SCXI-1327 776572-20
Text: SCXI-1120, SCXI-1120D 8-Channel Isolation Amplifiers SCXI-1120, SCXI-1120D Isolated signal conditioning for Thermocouples Millivolt and volt inputs 4-20 mA or 0-20 mA inputs Isolates, amplifies, and multiplexes 8 channels 250 Vrms working isolation per channel
|
Original
|
PDF
|
SCXI-1120,
SCXI-1120D
SCXI-1120)
SCXI-1120D)
SCXI-1327
220/gain)
SCXI-1120D
SCXI-1120
TBX-1329
SCXI-1327
776572-20
|
THERMOCOUPLE AMPLIFIER
Abstract: SCXI-1102 SCXI-1310
Text: SCXI 32-Channel Thermocouple Amplifier SCXI-1102 SCXI-1102 Features 32 differential channels Low-noise signal conditioning for: Thermocouples Low-bandwidth millivolt and volt signals 4-20 mA or 0-20 mA inputs Lowpass noise filters on every channel Programmable instrumentation amplifier
|
Original
|
PDF
|
32-Channel
SCXI-1102
SCXI-1102
96-pin
SCXI-1200,
PCI-1200,
DAQCard-1200,
THERMOCOUPLE AMPLIFIER
SCXI-1310
|
INA102
Abstract: INA102AG INA102AU ECG Amplifier
Text: INA102 Low Power INSTRUMENTATION AMPLIFIER FEATURES APPLICATIONS ● LOW QUIESCENT CURRENT: 750µA max ● AMPLIFICATION OF SIGNALS FROM SOURCES SUCH AS: Strain Gages Weigh Scale Applications Thermocouples Bridge Transducers ● REMOTE TRANSDUCER AMPLIFIER
|
Original
|
PDF
|
INA102
INA102
INA102AG
INA102AU
ECG Amplifier
|
circuit diagram for split air conditioner
Abstract: AD597 AD597A circuit op07 for thermocouple type k control thermocouple AD597H circuit diagram of split air conditioner OVEN* temperature sensor AD594 AD596
Text: a FEATURES Low Cost Operates with Type J AD596 or Type K (AD597) Thermocouples Built-In Ice Point Compensation Temperature Proportional Operation – 10 mV/؇C Temperature Setpoint Operation – ON/OFF Programmable Switching Hysteresis High Impedance Differential Input
|
Original
|
PDF
|
AD596)
AD597)
AD596
/AD597*
O-100
AD596/AD597
C831b
circuit diagram for split air conditioner
AD597
AD597A
circuit op07 for thermocouple type k
control thermocouple
AD597H
circuit diagram of split air conditioner
OVEN* temperature sensor
AD594
|
PC-SSO-32
Abstract: LTKA0x LT1091A thermocouple copper ltc 1025 LT1025 LT398 serial "compass Sensor" application note LT1034 chopper transformer
Text: Application Note 28 February 1988 Thermocouple Measurement Jim Williams Introduction Thermocouples in Perspective In 1822, Thomas Seebeck, an Estonian physician, accidentally joined semicircular pieces of bismuth and copper Figure 1 while studying thermal effects on galvanic arrangements. A nearby compass indicated a magnetic disturbance. Seebeck experimented repeatedly with different
|
Original
|
PDF
|
an28f
AN28-19
AN28-20
PC-SSO-32
LTKA0x
LT1091A
thermocouple copper
ltc 1025
LT1025
LT398
serial "compass Sensor" application note
LT1034
chopper transformer
|
TBUS-2
Abstract: 13001 HF
Text: MINI MCR-SL-TC-UI -NC Configurable Temperature Transducer for Type J and K Thermocouples Data Sheet 11/2004 Product Description Features The MINI MCR-SL-TC-UI(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of type J and K
|
Original
|
PDF
|
|
SCXI-1121
Abstract: SCXI-1120
Text: SCXI-1121 SCXI 4-Channel Isolation Amplifier with Excitation SCXI-1121 Isolated signal conditioning for Strain gauges RTDs Thermistors Millivolt and volt inputs 4-20 mA or 0-20 mA with resistor kit Thermocouples 4 isolated current or voltage excitation channels
|
Original
|
PDF
|
SCXI-1121
SCXI-1327
SCXI-1321
SCXI-1327
SCXI-1305
AT-MIO-16E-2
AT-MIO-16X
SCXI-1121
SCXI-1120
|
|
MAX31855J
Abstract: MAX31855 max31855k 200nC Thermocouple Type K MAX31855T
Text: 19-5793; Rev 0; 3/11 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K, J, N, T, or E type thermocouple. Contact the factory for S and R type thermocouples. The data is output in a signed 14-bit, SPI compatible, read-only format. This converter resolves
|
Original
|
PDF
|
MAX31855
14-bit,
1800NC
-270NC,
-200NC
700NC
MAX31855J
max31855k
200nC
Thermocouple Type K
MAX31855T
|
PWS740
Abstract: No abstract text available
Text: ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● ● ● ● ● ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION
|
Original
|
PDF
|
ISO120
ISO121
ISO120:
1500Vrms
ISO121:
3500Vrms
115dB
24-PIN
ISO120)
PWS740
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog IB IL TEMPCON UTH Order No.: 2819312 Inline temperature regulators, without accessories, 8 inputs for thermocouples, 8 outputs, 24 V DC, 2-wire connection method
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Or, Call Customer Service at 1-800-548-6132 USA Only is s a r m 1S 0 2 1 2 P q p IS0212P • p APPLICATIONS • • • • • INDUSTRIAL PROCESS CONTROL: Transducer Channel Isolator for Thermocouples, RTDs, Pressure Bridges, Flow Meters • 4mA TO 20mA LOOP ISOLATION
|
OCR Scan
|
PDF
|
IS0212P
12-BIT
IS0212P
100kQ
1-M0-548-6132
|
Untitled
Abstract: No abstract text available
Text: B U R R - B R O W N <i [ ] IS0212P r Low Cost, Two-Port Isolated, 1500Vrms ISOLATION AMPLIFIER FEATURES APPLICATIONS • 12-BIT ACCURACY • INDUSTRIAL PROCESS CONTROL: Transducer Channel Isolator for Thermocouples, RTDs, Pressure Bridges, Flow Meters • 2.5mA typ QUIESCENT CURRENT
|
OCR Scan
|
PDF
|
IS0212P
1500Vrms
12-BIT
4-20mA
|
ERF 2030
Abstract: LTKA LT1025AC PL II thermocouple LT1025 T1025 LT1025ACN8 LT1025AM LT1025AMJ8 LT1025C
Text: _ LT1025 r r u n m te c h n o lo g y Micropower Thermocouple Cold Junction Compensator F€ATUA€S D C S C R IP T IO n • ■ ■ ■ 80iiA Supply Current 4V to 36V Operation 0.5°C Initial Accuracy A Version Compatible with Standard Thermocouples
|
OCR Scan
|
PDF
|
80/iA
10mV/Â
LT1025
LT1025
588-r
ERF 2030
LTKA
LT1025AC
PL II thermocouple
T1025
LT1025ACN8
LT1025AM
LT1025AMJ8
LT1025C
|
Signal Conditioners
Abstract: AD595 ice point compensation AD594 AD595 thermocouple AD596 temperature transducers
Text: Signal Conditioners Temperature Transducer Signal Conditioners -IN -A LM +ALM V+ COM » VO FB AD594/AD595 Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-In Ice Point Compensation
|
OCR Scan
|
PDF
|
AD594/AD595
AD594)
AD595)
10mV/Â
AD596
Signal Conditioners
AD595
ice point compensation
AD594
AD595 thermocouple
AD596
temperature transducers
|
AC1501
Abstract: AD2036 ad2009 "BCD Switch" AD2016 digital clock diagram built by bcd segment thermocouple multiplexer L type thermocouple conversion table AD2022 COUNTER LED bcd
Text: ► ANALOG DEVICES 6 Channel Scanning Digital Thermometer FEA TUR ES Automatic Scan of 6 Thermocouples TC's Manual Selection of Individual TC's External Channel Selection by BCD Code J, K, or T Thermocouple °C or °F: Readout Self Contained Linearization
|
OCR Scan
|
PDF
|
AD2036
1151-MAX
AC1501
ad2009
"BCD Switch"
AD2016
digital clock diagram built by bcd segment
thermocouple multiplexer
L type thermocouple conversion table
AD2022
COUNTER LED bcd
|
LM 1605 CK
Abstract: AD596A AD597H transistor D596 LT 6243
Text: ANALOG DEVICES FEATURES Low Cost Operates w ith Type J AD596 or Type K (AD597) Thermocouples Built-In Ice Point Compensation Tem perature Proportional Operation - 1 0 m V /°C Tem perature Setpoint Operation - O N /O FF Programmable Switching Hysteresis
|
OCR Scan
|
PDF
|
AD596)
AD597)
AD596/AD597
LM 1605 CK
AD596A
AD597H
transistor D596
LT 6243
|
2SC 8050
Abstract: 403M AC1226 Amplifier type t thermocouple 1B51 circuit with thermocouple application cold junction compensation of t type thermocouple kovar thermocouple
Text: Micropower Thermocouple Cold Junction Compensator A N A LO G ► D E V IC E S ri-s - X .r ' : -, -?•*# - f r s K ^ s g l FEATURES 80|jlA Supply Current 4V to 36V Operation 0.5°C Typical Initial Accuracy Compatible with Standard Thermocouples E. J, K, R, S. T
|
OCR Scan
|
PDF
|
10mV/cC
AC1226
2SC 8050
403M
Amplifier type t thermocouple
1B51
circuit with thermocouple application
cold junction compensation of t type thermocouple
kovar thermocouple
|