Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    UL 1059 TORQUE Search Results

    UL 1059 TORQUE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DRV8461DDWR Texas Instruments 65-V, 3-A dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 44-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8452PWPR Texas Instruments 50-V, 5-A, dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 28-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8462DDWR Texas Instruments 65-V, 10-A, dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 44-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8461SPWPR Texas Instruments 65-V, 3-A dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 28-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8452SPWPR Texas Instruments 50-V, 5-A, dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 28-HTSSOP -40 to 125 Visit Texas Instruments

    UL 1059 TORQUE Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    ceramic coaxial resonators

    Abstract: No abstract text available
    Text: FILTERED TERMINAL BLOCKS Eliminate Electromagnetic Interference EMI UL Standard 1059 Compliant Te rminal Blo c k s CTS UL-recognized filtered terminal blocks are specifically designed to save time and money for EMI filtering applications. By combining a filtering component with an industry standard terminal block, CTS


    Original
    PDF

    ral 7016

    Abstract: EN 60998 wire UL94 ak 38
    Text: AK 100 VERTICAL AK 100 HORIZONTAL AK 100/. - 5,0 - V - grey AK 100/. - 5,0 - H - grey 2-12 poles, Spacing 5,0 mm insert required no. of poles . 2-12 poles, Spacing 5,0 mm insert required no. of poles . Ratings: Ratings: UL 1059 Rated Voltage Rated Current


    Original
    PDF D-59368 ral 7016 EN 60998 wire UL94 ak 38

    EN 60998

    Abstract: No abstract text available
    Text: AK 2200 VERTICAL AK 2200 HORIZONTAL AK 2200/. - 5,0 - V - green AK 2200/. - 5,0 - H - green 1-n poles, Spacing 5,0 mm insert required no. of poles . 1-n poles, Spacing 5,0 mm insert required no. of poles . Ratings: Ratings: UL 1059 Rated Voltage Rated Current


    Original
    PDF D-59368 EN 60998

    ral 7016

    Abstract: No abstract text available
    Text: AK 550 VERTICAL AK 550 HORIZONTAL AK 550/. - 3,5 - V - grey AK 550/. - 3,5 - H - grey 2-16 poles, Spacing 3,5 mm insert required no. of poles . 2-16 poles, Spacing 3,5 mm insert required no. of poles . Ratings: Ratings: UL 1059 Rated Voltage Rated Current


    Original
    PDF D-59368 ral 7016

    DP 804 C

    Abstract: ST723B38 Dp 104 ST723B3802 E62806
    Text: Studded Power Feed Thru Terminal Blocks ST723B38 Series back mount Specifications: • • • • 600 Volts AC/DC (UL 1059 Class B and C) 380 Amps Wire Range 500 kcmil - 2/0 AWG Accommodates Two Hole Compression Lugs on 1” Centers - wires larger than 250 kcmil require


    Original
    PDF ST723B38 125oC E62806 ST723B3802 ST723B3802 DP 804 C Dp 104 E62806

    AKZ120

    Abstract: d5936
    Text: AKZ 120 VERTICAL AKZ 120 HORIZONTAL AKZ 120/. - 5,08 - V - grey AKZ 120/. - 5,08 - H - grey 2-12 poles, Spacing 5,08 mm insert required no. of poles . 2-12 poles, Spacing 5,08 mm insert required no. of poles . Ratings: Ratings: UL 1059 Rated Voltage Rated Current


    Original
    PDF D-59368 AKZ120 d5936

    ST715S1902

    Abstract: E62806 80AMPS
    Text: Studded Power Feed Thru Terminal Blocks ST715S1902 Electrical: • • • • 300 Volts AC/DC UL 1059 Class B and C 80 Amps Wire Range #6 - #14 Accommodates Two Hole Compression Lugs on .625” Centers General/Mechanical: • • • • • • • •


    Original
    PDF ST715S1902 125oC E62806 ST715S902 C71502 ST715S1902 E62806 80AMPS

    ST722B2502

    Abstract: ST722B C72201 E62806 ST722
    Text: Studded Power Feed Thru Terminal Blocks ST722B Series back mount Studded Power Feed Thru Terminal Blocks Specifications: Electrical: • • • • 300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625”


    Original
    PDF ST722B 125oC E62806 LR19766 ST722B2502 C72201 C72202 C72203 C72204 C72205 ST722B2502 C72201 E62806 ST722

    ST722E

    Abstract: ST722E2503 E62806 ST722 C72201 ST722EXX02 ST722EXX03
    Text: Studded Power Feed Thru Terminal Blocks ST722E Series end mount Specifications: Studded Power Feed Thru Terminal Blocks Electrical: • • • • 300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625”


    Original
    PDF ST722E 125oC E62806 LR19766 ST722E2503 C72201 C72202 C72203 C72204 C72205 ST722E2503 E62806 ST722 C72201 ST722EXX02 ST722EXX03

    Untitled

    Abstract: No abstract text available
    Text: AKZ 1200 AK Z 1550 AKZ 1200/. - 5,08 - green AK(Z) 1550/. - 3,5 (3,81) - green 2-24 poles, Spacing 5,08 mm insert required no. of poles . 2-20 (16) poles, Spacing 3,5 or 3,81 mm insert required no. of poles . Ratings: Ratings: UL 1059 Rated Voltage Rated Current


    Original
    PDF D-59368

    ST722SXX01

    Abstract: C72206 C72201 C72202 E62806 ST722 ST722SXX02
    Text: Studded Power Feed Thru Terminal Blocks ST722S Series slide-in mount Studded Power Feed Thru Terminal Blocks Specifications: Electrical: • • • • 300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625”


    Original
    PDF ST722S 125oC E62806 LR19766 ST722S2502 C72201 C72202 C72203 C72204 C72205 ST722SXX01 C72206 C72201 C72202 E62806 ST722 ST722SXX02

    akz950

    Abstract: 1059 z950 AK 950 D-59368
    Text: AK Z 950 AKZ 960 AK(Z) 950/. - 5,0 (5,08) - green AKZ 960/. - 7,62 - green 2-24 poles, Spacing 5,0 mm or 5,08 mm insert required no. of poles . 2-16 poles, Spacing 7,62 mm insert required no. of poles . Ratings: Ratings: UL 1059 Rated Voltage Rated Current


    Original
    PDF D-59368 akz950 1059 z950 AK 950

    copper bus bar torque

    Abstract: E62806
    Text: Product Data Sheet 144X122 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 260 Amps, 600 Volts AC/DC Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 260A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    PDF 144X122 IP-10 CC144X copper bus bar torque E62806

    UL 1059 terminal block

    Abstract: IEC 60947-7-1 E62806
    Text: Product Data Sheet 144X614 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 840 Amps, 600 Volts AC/DC Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 840A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    PDF 144X614 IP-10 E62806 LR19766 CC144X UL 1059 terminal block IEC 60947-7-1 E62806

    142X122

    Abstract: IEC 60947-7-1 E62806
    Text: Product Data Sheet 142X122 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 200 Amps, 600 Volts AC/DC Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 200A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    PDF 142X122 IP-10 E62806 LR19766 CC142X 142X122 IEC 60947-7-1 E62806

    copper bus bar torque

    Abstract: IEC 60947-7-1 LR19766 E62806 143X563
    Text: Product Data Sheet 143X563 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 230 Amps, 600 Volts AC/DC Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 230A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    PDF 143X563 E62806 LR19766 CC143X copper bus bar torque IEC 60947-7-1 LR19766 E62806 143X563

    IEC 60947-7-1

    Abstract: E62806 UL 1059 torque
    Text: Product Data Sheet 145X606 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 410 Amps, 600 Volts AC/DC Wire Range: Line side: 1/2 - 13 X 1 5/16 stud Load Side: 1/2 - 13 X 1 5/16 stud Electrical Ratings: • 410A copper wire • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    PDF 145X606 E62806 LR19766 CC145X IEC 60947-7-1 E62806 UL 1059 torque

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 145X583 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 360 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 3/8 - 16 X 1 7/16 stud Load Side: (2) 1/4 - 20 X 1 7/16 stud Electrical Ratings: • 360A copper wire • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    PDF 145X583 Ins1059 E62806 LR19766 CC145X E62806

    copper bus bar torque

    Abstract: E62806
    Text: Product Data Sheet 145X573 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 360 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 3/8 - 16 X 1 7/16 stud Load Side: (2) 3/8 - 16 X 1 7/16 stud Electrical Ratings: • 360A copper wire • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    PDF 145X573 Ins059 E62806 LR19766 CC145X copper bus bar torque E62806

    E62806

    Abstract: Marathon
    Text: Product Data Sheet 1XX Series Std Replace “XX” with 01 through 36 for number of poles Terminal Block– Closed Back 20 Amps, 250 Volts AC/DC (6 Pole shown) Copper Wire Only Wire Range with Wire Binding Screw: #12 - #22 AWG 3/8” Centers See table below for Wire Classes and torque


    Original
    PDF

    6G38 TSKK F

    Abstract: UL 1059 terminal block UL 1059 torque
    Text: Product Data Sheet 6G38 TSKK F 3/8” Sectional Terminal Block Flat Mount 40 Amps, 600 Volts AC/DC 32 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #10 - #22 AWG TSKK: Tubular Connector with Wire Protector Wire Termination Torque: 16 in. lbs


    Original
    PDF IP-20 6G38 TSKK F UL 1059 terminal block UL 1059 torque

    6H12TSCUF

    Abstract: E62806 J-12 D570
    Text: Product Data Sheet 6H12-TSCU-F 1/2” Sectional Terminal Block Flat Mount 70 Amps, 600 Volts AC/DC 24 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #4 - #16 AWG TS: Tubular Screw Wire Termination Torque: 20 in. lbs See table below for Wire Classes and torque


    Original
    PDF 6H12-TSCU-F 6H12-E-F 6H12TSCUF E62806 J-12 D570

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 6G38 TSKK F 3/8” Sectional Terminal Block Flat Mount 40 Amps, 600 Volts AC/DC 32 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #10 - #22 AWG TSKK: Tubular Connector with Wire Protector Wire Termination Torque: 16 in. lbs


    Original
    PDF

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 6G38 TS C 3/8” Sectional Terminal Block Channel Mount 50 Amps, 600 Volts AC/DC 32 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #8 - #18 AWG TS: Tubular Connector Wire Termination Torque: 16 in. lbs See table below for Wire Classes and torque


    Original
    PDF