    TEDEA Datasheets (4)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    1010 Tedea-Huntleigh Low Cost Single Point Mode Cell Scan PDF
    Model 601 Tedea-Huntleigh S Type Load Cells Original PDF
    Model 616 Tedea-Huntleigh S Type Load Cells Original PDF
    Model 620 Tedea-Huntleigh S Type Load Cell Original PDF

    TEDEA Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: Model 1250 Tedea-Huntleigh Aluminum High Capacity Single-Point Load Cell FEATURES • Capacities 50–1500 kg • Aluminum construction • Single-point 800 x 800 mm platform • OIML R60 and NTEP approved • IP65 protection • Available with metric and UNC threads


    Original
    PDF 27-Apr-2011

    Untitled

    Abstract: No abstract text available
    Text: Model T-End Foot Tedea-Huntleigh Load Cell Mounting Feet FEATURES • Adjustable height or fixed height version • Designed to work with T-end version shear beams • Low profile • Stainless steel • Anti-vibration • Easy installation DESCRIPTION T-End mounting feet are ideal for platform use where a


    Original
    PDF 27-Apr-2011

    Untitled

    Abstract: No abstract text available
    Text: Model 1320 Tedea-Huntleigh High Capacity Single-Point Load Cell FEATURES • Capacities 1000–2000 kg • Aluminum construction • Single-point 1200 x 1200 mm platform • OIML R60 and NTEP approved • IP66 protection • Available with metric threads • Optional


    Original
    PDF 27-Apr-2011

    Untitled

    Abstract: No abstract text available
    Text: Model 122 Tedea-Huntleigh Heavy Duty Compression Load Cell FEATURES • Capacities 50–150 ton • Ideal for multi-cell applications • Compact, economical, column design • Hermetically sealed to IP68 • 6-Wire sense circuit • Stainless steel housing as standard


    Original
    PDF 27-Apr-2011

    Untitled

    Abstract: No abstract text available
    Text: Model 1033 Tedea-Huntleigh Low Profile Single-Point Load Cell FEATURES • Capacities 10–30 kg • Aluminum construction • Single-point 400 x 400 mm platform • OIML R60 approved • IP66 protection • Available with metric and UNC threads • Optional


    Original
    PDF 27-Apr-2011

    Tedea-Huntleigh* model 240

    Abstract: SINGLE POINT load cell C3 CLASS single LOAD CELL Tedea-Huntleigh* rs232 weight sensor load cell 240 tedea Tedea-Huntleigh BE digital Weighing machine TEDEA TEDEA 240d
    Text: Model 240D Vishay Tedea-Huntleigh Digital Fluid Damped Single Point Load Cell FEATURES • Fully calibrated and filtered digital output • High update rate, up to 1200 updates per second • Checkweigher function - reading acquired over period set by remote sensor trigger


    Original
    PDF 08-Apr-05 Tedea-Huntleigh* model 240 SINGLE POINT load cell C3 CLASS single LOAD CELL Tedea-Huntleigh* rs232 weight sensor load cell 240 tedea Tedea-Huntleigh BE digital Weighing machine TEDEA TEDEA 240d

    Tedea-Huntleigh

    Abstract: TEDEA 240 MTS-BASE TEDEA TEDEA 220 Tedea-Huntleigh* model 240 VISHAY - Model 220 Silo Mount 220 tedea model 220 VISHAY Model 220 Silo Mount 220 simple weigh scales
    Text: Model 220 Rocker Pin Mount Vishay Tedea-Huntleigh Rocker Pin For Weighbridge Truck Scale FEATURES • For use on steel or concrete weighbridges • Above ground or pit mounted • Stainless steel pin • Plated steel base • Simple installation • Low profile


    Original
    PDF 08-Apr-05 Tedea-Huntleigh TEDEA 240 MTS-BASE TEDEA TEDEA 220 Tedea-Huntleigh* model 240 VISHAY - Model 220 Silo Mount 220 tedea model 220 VISHAY Model 220 Silo Mount 220 simple weigh scales

    load cell 100kg

    Abstract: SINGLE POINT load cell C3 CLASS Tedea-Huntleigh IEC wiring schematic with overload single LOAD CELL
    Text: Model 1142 Vishay Tedea-Huntleigh Single Point Stainless Steel Load Cell FEATURES • • • • • • • Capacity range: 10 to 150kg Stainless steel construction Single point 400 x 400mm platform Sealed to IP66 Compact size: only 40mm high OIML approved to C3 20 - 100kg


    Original
    PDF 150kg 400mm 100kg) 08-Apr-05 load cell 100kg SINGLE POINT load cell C3 CLASS Tedea-Huntleigh IEC wiring schematic with overload single LOAD CELL

    bottle filling circuit diagram

    Abstract: schematic diagram RPM meter bottle filling diagram bottle filling machine bottle filling wiring diagram vishay vt 300 wiring schematic Tedea-Huntleigh by 1330 Tedea-Huntleigh silicone fluid
    Text: Model 1430 Vishay Tedea-Huntleigh Damped Load Cells for Rotary Filling Machines FEATURES • Capacities: 3kg, 17lbs, 23lbs • Stainless Steel Construction • Insensitive to rotary dynamic forces • Single Point Performance • Rotary speed to 13rpm at 1m radius


    Original
    PDF 17lbs, 23lbs 13rpm 08-Apr-05 bottle filling circuit diagram schematic diagram RPM meter bottle filling diagram bottle filling machine bottle filling wiring diagram vishay vt 300 wiring schematic Tedea-Huntleigh by 1330 Tedea-Huntleigh silicone fluid

    TEDEA

    Abstract: 1041 Tedea-Huntleigh BY 1040 Load cells tedea Tedea-Huntleigh 1040
    Text: TEDEA - HUNTLEIGH Models 1040 & 1041 Single Point Load Cells Models 1040 and 1041 are low profile single point load cells designed for direct mounting of low cost weighing platforms. Their small physical size, combined with high accuracy and low cost, makes these load cells ideally suited


    Original
    PDF 400mm 400mm DS1040-2, TEDEA 1041 Tedea-Huntleigh BY 1040 Load cells tedea Tedea-Huntleigh 1040

    SINGLE POINT load cell C3 CLASS

    Abstract: TEDEA 1250 SINGLE POINT load cell model 1250 Weighing scale diagram OIML C3 vishay vt 300 wiring schematic 1500kg Tedea-Huntleigh
    Text: Model 1250 Vishay Tedea-Huntleigh Aluminum High Capacity Single Point Load Cell FEATURES • • • • • • Capacities 50 - 1500kg Aluminum construction Single point 600 x 600mm platform OIML R60 and NTEP approved IP65 protection Available with metric and UNC threads


    Original
    PDF 1500kg 600mm 08-Apr-05 SINGLE POINT load cell C3 CLASS TEDEA 1250 SINGLE POINT load cell model 1250 Weighing scale diagram OIML C3 vishay vt 300 wiring schematic 1500kg Tedea-Huntleigh

    4514 DATASHEET

    Abstract: TEDEA 9A 2636 tedea 620 x capacities "s type load cell"
    Text: TEDEA - HUNTLEIGH Model 620 ‘S’ Type Load Cell Model 620 is an advanced concept in providing the weighing industry with the ultimate protection necessary for today’s hostile weighing environment. Its all welded sealing combined with high accuracy, make this


    Original
    PDF DS620-3, 4514 DATASHEET TEDEA 9A 2636 tedea 620 x capacities "s type load cell"

    Tedea-Huntleigh

    Abstract: 2000kg TEDEA
    Text: Model 3520 Vishay Tedea-Huntleigh Stainless Steel Shear Beam Load Cell FEATURES • • • • Capacities 500 - 2000kg Stainless steel construction OIML R60 approved Sealed to IP67 OPTIONAL FEATURES • EEx ia IIC T6 hazardous area approval DESCRIPTION APPLICATIONS


    Original
    PDF 2000kg 08-Apr-05 Tedea-Huntleigh 2000kg TEDEA

    load cell 100kg

    Abstract: SINGLE POINT load cell C3 CLASS Tedea-Huntleigh 1130 Tedea-Huntleigh BY TEDEA 1130 Tedea-Huntleigh OIML C6 vishay vt 300 wiring schematic
    Text: Model 1130 Vishay Tedea-Huntleigh Stainless Steel Single Point Load Cell FEATURES • • • • • • Capacities 7 - 100kg Stainless steel construction Single point 400 x 400mm platform OIML R60 and NTEP approved IP66 protection Available with metric and UNC threads


    Original
    PDF 100kg 400mm 08-Apr-05 load cell 100kg SINGLE POINT load cell C3 CLASS Tedea-Huntleigh 1130 Tedea-Huntleigh BY TEDEA 1130 Tedea-Huntleigh OIML C6 vishay vt 300 wiring schematic

    TEDEA

    Abstract: Tedea-Huntleigh Tedea-Huntleigh* 355 TEDEA model 380 Tedea-Huntleigh model 355 BELT Weighing scale single LOAD CELL vishay vt 300 wiring schematic Tedea-Huntleigh BY
    Text: Model 355 Vishay Tedea-Huntleigh Welded, Hermetically Sealed Load Cell FEATURES • • • • Capacities 5 - 500kg Stainless steel construction OIML R60 and NTEP approved IP68 protection OPTIONAL FEATURES • EEx ia IIC T6 hazardous area approval • FM approval available


    Original
    PDF 500kg 08-Apr-05 TEDEA Tedea-Huntleigh Tedea-Huntleigh* 355 TEDEA model 380 Tedea-Huntleigh model 355 BELT Weighing scale single LOAD CELL vishay vt 300 wiring schematic Tedea-Huntleigh BY

    Tedea-Huntleigh

    Abstract: weighing scales 1002k SINGLE POINT single LOAD CELL
    Text: Model 1002 Vishay Tedea-Huntleigh Aluminum Single Point Load Cell FEATURES • Capacities 0.5 - 5kg for 350 ohm • Capacities 5 - 20kg for 1000 ohm • Aluminum construction • Single point 200 x 200mm platform • IP66 protection DESCRIPTION APPLICATIONS


    Original
    PDF 200mm 08-Apr-05 Tedea-Huntleigh weighing scales 1002k SINGLE POINT single LOAD CELL

    SINGLE POINT load cell C3 CLASS

    Abstract: OIML c6 tedea IEC wiring schematic with overload vishay vt 300 wiring schematic OIML-R76 Tedea-Huntleigh single LOAD CELL ip66 wiring diagram
    Text: Model 1265 Vishay Tedea-Huntleigh Single Point Load Cell FEATURES • Capacity range: 100 to 660kg • Rigid, anodized aluminum construction • OIML approved to C6 150 - 660kg • Single point 800 x 800mm platform • Minimal deflection and high natural frequency


    Original
    PDF 660kg 660kg) 800mm 08-Apr-05 SINGLE POINT load cell C3 CLASS OIML c6 tedea IEC wiring schematic with overload vishay vt 300 wiring schematic OIML-R76 Tedea-Huntleigh single LOAD CELL ip66 wiring diagram

    MTS-BASEKIT-30T

    Abstract: TSD.0007 Tedea-Huntleigh MTS-COMP-50T 220-30-50T TEDEA rocker MTS-ROCKER-50T Tedea-Huntleigh BY MTS-COMP-30T
    Text: Model 220-30-50T Weighbridge Mount Vishay Tedea-Huntleigh Mount For Weighbridge Mount/Truck Scales FEATURES • For use on steel or concrete weighbridges • Above ground or pit mounted • Composite rubber and plated steel construction • Low profile • Simple installation


    Original
    PDF 220-30-50T 08-Apr-05 MTS-BASEKIT-30T TSD.0007 Tedea-Huntleigh MTS-COMP-50T TEDEA rocker MTS-ROCKER-50T Tedea-Huntleigh BY MTS-COMP-30T

    Tedea-Huntleigh 1040

    Abstract: TEDEA SINGLE POINT load cell C3 CLASS load cell up to 50kg Tedea-Huntleigh BY 1040 bench Weighing scale circuit diagram single LOAD CELL Tedea-Huntleigh C3-1000 Load cells
    Text: Model 1040/1041 Vishay Tedea-Huntleigh Low Capacity Single Point Aluminum Load Cells FEATURES • • • • • • Capacities 5-100kg Aluminum construction Single point 400 x 400mm platform OIML R60 and NTEP approved IP65 protection Available with metric and UNC threads


    Original
    PDF 5-100kg 400mm IP67available 08-Apr-05 Tedea-Huntleigh 1040 TEDEA SINGLE POINT load cell C3 CLASS load cell up to 50kg Tedea-Huntleigh BY 1040 bench Weighing scale circuit diagram single LOAD CELL Tedea-Huntleigh C3-1000 Load cells

    tedea 1042

    Abstract: Tedea-Huntleigh 9010 Tedea-Huntleigh 121 tedea huntleigh load cell 3410 Tedea-Huntleigh* 1263 Tedea-Huntleigh* 1015 Tedea-Huntleigh 1040 1022 load cell ATEX 3410 load cell Tedea 3410
    Text: V I S H A Y I N T E R T E C H N O L O GY , I N C . L O A D C E L L S Load Cells V is hay Te de a- Huntle igh pro d uct O verview w w w. v i s h a y m g . c o m Load Cells Vishay Tedea-Huntleigh Aluminum Single-Point Load Cells • Insensitive to off-center loading


    Original
    PDF VTR-PL0008-0705 tedea 1042 Tedea-Huntleigh 9010 Tedea-Huntleigh 121 tedea huntleigh load cell 3410 Tedea-Huntleigh* 1263 Tedea-Huntleigh* 1015 Tedea-Huntleigh 1040 1022 load cell ATEX 3410 load cell Tedea 3410

    Untitled

    Abstract: No abstract text available
    Text: Model 619 Tedea-Huntleigh S-Type Alloy Steel Load Cell FEATURES • Capacities 1500–6000 kg • Alloy steel construction • Sealing: welded to IP67 • S-Type design for use in tension and compression • Choice of mounting threads metric or unified systems


    Original
    PDF 27-Apr-2011

    Untitled

    Abstract: No abstract text available
    Text: Model 1022 Tedea-Huntleigh Single-Point Aluminum Load Cell FEATURES • Capacities: 3–200 kg • Only 22 mm high • Aluminum construction • Single-point 350 x 350 mm platform • IP66 protection • OIML R60 and NTEP approved • Optional ❍❍ EEx ia IIC T4 - ATEX hazardous area approval


    Original
    PDF 18-Jul-2012

    Untitled

    Abstract: No abstract text available
    Text: Model 1002 Tedea-Huntleigh Aluminum Single-Point Load Cell FEATURES • Capacities 0.5–5 kg for 350 ohm • Capacities 5–20 kg for 1000 ohm • Aluminum construction • Single-point 200 x 200 mm platform • IP66 protection APPLICATIONS • Small scales


    Original
    PDF 1000-ohm 27-Apr-2011

    Tedea-Huntleigh 4158

    Abstract: No abstract text available
    Text: Model 4158 Tedea-Huntleigh Alloy Steel Double-Ended Shear Beam FEATURES • Capacities 10k–75k lbs • Low profile design for weigh bridge and silo applications • Nickel plated alloy steel construction • NTEP approved • IP67 protection • Optional


    Original
    PDF 27-Apr-2011 Tedea-Huntleigh 4158