Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    UL943 Search Results

    UL943 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • •  Meets 2015 UL943 Self-Test GFCI Requirement  Periodic EOL Testing without Compromising Normal GFCI Protection        Built-in Noise Filters Reduce False EOL Signals


    Original
    PDF FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A

    Untitled

    Abstract: No abstract text available
    Text: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),


    Original
    PDF NCS37010 NCS37010 UL943 NCS37010/D

    Untitled

    Abstract: No abstract text available
    Text: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),


    Original
    PDF NCS37010 UL943 NCS37010/D

    scr drive circuit diagram

    Abstract: LM1851 LM1851AN RV4145M 5KQ30
    Text: www.fairchildsemi.com LM1851 Ground Fault Interrupter Features • • • • No potentiometer required Direct interface to SCR Supply voltage derived from AC line—26V shunt Adjustable sensitivity • • • • Grounded neutral fault detection Meets UL943 standards


    Original
    PDF LM1851 line--26V UL943 LM1851 DS30001851 scr drive circuit diagram LM1851AN RV4145M 5KQ30

    Untitled

    Abstract: No abstract text available
    Text: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • •  Meets 2015 UL943 Self-Test GFCI Requirement  Periodic EOL Testing without Compromising Normal GFCI Protection        Built-in Noise Filters Reduce False EOL Signals


    Original
    PDF FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A

    schematic diagram DC circuit breaker

    Abstract: ac voltage regulator using SCR circuit diagram scr drive circuit diagram schematic diagram ac voltage regulator 100-240 v schematic diagram Power supply 500w Ground fault Interrupter IC schematic diagram ac 220v voltage regulator schematic diagram for ac power line voltage conditioner LM1851 LM1851AN
    Text: Electronics Semiconductor Division LM1851 Ground Fault Interrupter Features ¥ ¥ ¥ ¥ No potentiometer required Direct interface to SCR Supply voltage derived from AC lineÑ26V shunt Adjustable sensitivity ¥ ¥ ¥ ¥ Grounded neutral fault detection Meets UL943 standards


    Original
    PDF LM1851 UL943 LM1851 DS3001851A schematic diagram DC circuit breaker ac voltage regulator using SCR circuit diagram scr drive circuit diagram schematic diagram ac voltage regulator 100-240 v schematic diagram Power supply 500w Ground fault Interrupter IC schematic diagram ac 220v voltage regulator schematic diagram for ac power line voltage conditioner LM1851AN

    SCHEMATIC circuit scr oscillator

    Abstract: GFCI schematic
    Text: NCS37000 Product Preview Ground Fault Circuit Interrupter GFCI Description The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and


    Original
    PDF NCS37000 UL943 QFN16 TSSOP-20 NCS37000/D SCHEMATIC circuit scr oscillator GFCI schematic

    Untitled

    Abstract: No abstract text available
    Text: NCS37000 Product Preview Ground Fault Circuit Interrupter GFCI Description The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and


    Original
    PDF NCS37000 NCS37000 UL943 QFN16 NCS37000/D

    Untitled

    Abstract: No abstract text available
    Text: NCS37010 Product Preview Self Test With Lockout Ground Fault Circuit Interrupter GFCI http://onsemi.com The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),


    Original
    PDF NCS37010 NCS37010 UL943 NCS37010/D

    SCR TRIGGER PULSE circuit

    Abstract: Ground Fault IC pin diagram of SCR KA2807 off23
    Text: www.fairchildsemi.com KA2807 Earth Leakage Detector Features Description • • • • • • KA2807 is a IC for ground fault circuit interrupters which are intended to provide electrical shock hazard protection from line-to-ground fault currents on grounded circuits of


    Original
    PDF KA2807 KA2807 UL943 SCR TRIGGER PULSE circuit Ground Fault IC pin diagram of SCR off23

    E41978

    Abstract: ul498 GFCI e419 GFPOEMM UL943 Ul-498
    Text: Product Datasheet - GFPOEMM Product Datasheet GFPOEMM - Circuit Guard Manual Set Portable GFCI Line Cords 15 & 20A 120V 15' GFCI power supply cord with stripped leads, manual set. Product Specifications GFCI Product Type Line Cord Type Industrial Amperage


    Original
    PDF UL498 UL943 E41978 UL94V-0 E41978 GFCI e419 GFPOEMM Ul-498

    UJT 2N2646

    Abstract: 2N2646 pin diagram UJT-2N2646 PIN DIAGRAM DETAILS UJT pin diagram 2N2646 pin diagram of UJT-2N2646 GE Transient Voltage Suppression Manual UJT THEORY AND CHARACTERISTICS 957B MDA2500 pn junction DIODE 1N4001
    Text: TVS/Zener Theory and Design Considerations Handbook HBD854/D Rev. 0, Jun−2005 SCILLC, 2005 Previous Edition © 2001 as Excerpted from DL150/D “All Rights Reserved’’ http://onsemi.com 1 Technical Information, Application Notes and Articles Zener Diode Theory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3


    Original
    PDF HBD854/D Jun-2005 DL150/D NLAS3158/D UJT 2N2646 2N2646 pin diagram UJT-2N2646 PIN DIAGRAM DETAILS UJT pin diagram 2N2646 pin diagram of UJT-2N2646 GE Transient Voltage Suppression Manual UJT THEORY AND CHARACTERISTICS 957B MDA2500 pn junction DIODE 1N4001

    KA2807

    Abstract: No abstract text available
    Text: www.fairchildsemi.com K A2 8 0 7 Ea r t h Le a k a ge De t e c t or Features Description • • • • • The KA2807 is a IC for ground fault circuit interrupters which are intended to provide an electrical shock hazard protection from line to ground fault currents on grounded circuits of 120V supplies.


    Original
    PDF KA2807 UL943

    GFCI schematic

    Abstract: No abstract text available
    Text: NCS37012 Product Preview Self Test Ground Fault Circuit Interrupter GFCI Description • 6.0 – 12 Volt Operation (120 − 480 V AC mains with the appropriate • • • • • • • • • • • series impedance) −40 to 85°C Very Low Power Consumption: <15 mW @ 5 V


    Original
    PDF NCS37012 UL943 NCS37012/D GFCI schematic

    GFCI schematic

    Abstract: ON-MCR08 scr driver ic for rectifier 3 phase
    Text: NCS37000 Ground Fault Circuit Interrupter GFCI Description Features • 6.0 – 12 Volt Operation (120 − 480 V AC mains with the appropriate • • • • • • • • • • series impedance) −40 to 85°C Very Low Power Consumption: <5 mW @ 5 V


    Original
    PDF NCS37000 UL943 QFN16 TSSOP-20 NCS37000/D GFCI schematic ON-MCR08 scr driver ic for rectifier 3 phase

    FM2807

    Abstract: No abstract text available
    Text: FM2807 Low Power Ground Fault Interrupter Specification Oct. 2007 FM2807 Low Power Ground Fault Interrupter Ver 1.0 Specification 1 INFORMATION IN THIS DOCUMENT IS INTENDED AS A REFERENCE TO ASSIST OUR CUSTOMERS IN THE SELECTION OF SHANGHAI FUDAN MICROELECTRONICS CO., LTD PRODUCT BEST SUITED TO THE CUSTOMER'S APPLICATION; THEY DO


    Original
    PDF FM2807

    Untitled

    Abstract: No abstract text available
    Text: 2 | PB-Series - Introduction PB-Series Ground Fault Circuit Protection The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. The new PB-Series, AC Residual Current Circuit Breaker


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: FAN4147 Ground Fault Interrupter Features Description ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ The FAN4147 is a low-power Ground Fault Interrupter GFI controller for detecting hazardous current paths to ground and ground-to-neutral faults. The FAN4147 application circuit opens the load contacts before a


    Original
    PDF FAN4147 FAN4147

    ENR5201

    Abstract: EDS-17 EDS271 EDS172 GFCI CPS152 CH-02 CROUSE-HINDS eds
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-1010-3 Name: 2P-1010 2P 100: DATE: JAN 19 2006 Time: 6:08:35 PM Operator: RB GFS ground fault circuit interrupters are used: ɀ with portable electrical equipment such as tools, lighting systems, compressors and


    Original
    PDF SYS19: CRMAIN06-1010-3 2P-1010 CPS152 ENR5201 EDS-17 EDS271 EDS172 GFCI CPS152 CH-02 CROUSE-HINDS eds

    l943

    Abstract: No abstract text available
    Text: LINEAR INTEGRATED CIRCUIT KA2807 EARTH LEAKAGE DETECTOR T h e K A 2807 is d e s ig n e d fo r u se in e a rth c ir c u it in te r ­ ru p te rs, fo r o p e ra tio n d ire c tly o ff th e A C lin e in te rru p te rs. F u ll a d va n ta g e o f th e U.S. UL943 tim in g s p e c ific a tio n


    OCR Scan
    PDF KA2807 UL943 UL943 l943

    scr 20f

    Abstract: No abstract text available
    Text: LINEAR INTEGRATED CIRCUIT KA2807 S DIP FEATURES • • • • • • • • • • Full Advantage Of The UL943 Built-In Voltage Regulator Sense Coll: 1000:1 GND/Neutral Coil: 200:1 Normal Fault Sensitivity Current Is 5mA Typical Trip Time In Normal Fault And Ground Neutral Fault


    OCR Scan
    PDF KA2807 UL943 800Hz, scr 20f

    Untitled

    Abstract: No abstract text available
    Text: KA2807 LINEAR INTEGRATED CIRCUIT EARTH LEAKAGE DETECTOR KA2807 is a 1C for ground fault circuit interrupters which are intend­ ed to provide electrical shock hazard protection from line-to-ground fault currents on grounded circuits of 120V supplies. FEATURES


    OCR Scan
    PDF KA2807 KA2807 UL943 800Hz,

    Untitled

    Abstract: No abstract text available
    Text: PRECISION FAILSAFE TH ER M A L-FU SE RESISTORS CUSTOM DESIGN - V2 W to 60 W A TT msmt •v TF SERIES FEATURES The Ultimate Failsafe Design! ■ Instrinsically safe, completely flameproof. Component opens without hazard of overheating. ■ Meets UL, FCC, REA and EIA requirements


    OCR Scan
    PDF 100CVS

    lm1851

    Abstract: No abstract text available
    Text: w w w .fa irc h ild s e m i.c o m S E M I C O N D U C T O R tm LM1851 Ground Fault I n t e r r u p t e r Features • • • • No potentiometer required Direct interface to SCR Supply voltage derived from AC line—26V shunt Adjustable sensitivity • •


    OCR Scan
    PDF LM1851 UL943 LM1851 DS30001851